Silica‐Templated Metal Organic Framework‐Derived Hierarchically Porous Cobalt Oxide in Nitrogen‐Doped Carbon Nanomaterials for Electrochemical Glucose Sensing. Issue 5 (29th January 2021)
- Record Type:
- Journal Article
- Title:
- Silica‐Templated Metal Organic Framework‐Derived Hierarchically Porous Cobalt Oxide in Nitrogen‐Doped Carbon Nanomaterials for Electrochemical Glucose Sensing. Issue 5 (29th January 2021)
- Main Title:
- Silica‐Templated Metal Organic Framework‐Derived Hierarchically Porous Cobalt Oxide in Nitrogen‐Doped Carbon Nanomaterials for Electrochemical Glucose Sensing
- Authors:
- Sun, Qiuhong
Ding, Junyang
Chen, Dandan
Han, Cheng
Jiang, Minghua
Li, Ting‐Ting
Hu, Yue
Qian, Jinjie
Huang, Shaoming - Abstract:
- Abstract: As glucose molecules are well recognized to supplement the main energy source of living cells as the intermediate product of metabolism in human body, it is of great importance to develop a convenient and quantitative glucose sensor with high selectivity, high sensitivity, and high accuracy. In this work, a simple and novel strategy has been developed to obtain a high‐performance non‐enzymatic glucose sensor by constructing hierarchically porous Co3 O4 embedded into the metal organic framework (MOF)‐derived N‐doped carbon matrix based on a SiO2 template, denoted as ST‐Co3 O4 . The removal of the SiO2 template creates abundant voids and a large specific surface for the obtained layered mesoporous ST‐Co3 O4 composite, which enhances the electron transfer kinetics and the ability to adsorb biomolecules, further greatly improving the surface reaction efficiency and promoting the improvement of its catalytic performance. Compared with pure Co3 O4 nanoparticles from ZIF‐67 without a silica template, as‐obtained ST‐Co3 O4 shows a good mesoporous environment, provides more active sites, and makes the non‐enzymatic glucose sensor exhibit high sensitivity (2860 μA mM −1 cm −2 ) and fast response time (<1 s) over a wide linear glucose concentration range of 1.0–1300.0 μM. Additionally, the ST‐Co3 O4 /CC electrode demonstrates good anti‐interference, high repeatability, and robust stability (>3000 s), which can repeatedly detect the glucose species in real human serumAbstract: As glucose molecules are well recognized to supplement the main energy source of living cells as the intermediate product of metabolism in human body, it is of great importance to develop a convenient and quantitative glucose sensor with high selectivity, high sensitivity, and high accuracy. In this work, a simple and novel strategy has been developed to obtain a high‐performance non‐enzymatic glucose sensor by constructing hierarchically porous Co3 O4 embedded into the metal organic framework (MOF)‐derived N‐doped carbon matrix based on a SiO2 template, denoted as ST‐Co3 O4 . The removal of the SiO2 template creates abundant voids and a large specific surface for the obtained layered mesoporous ST‐Co3 O4 composite, which enhances the electron transfer kinetics and the ability to adsorb biomolecules, further greatly improving the surface reaction efficiency and promoting the improvement of its catalytic performance. Compared with pure Co3 O4 nanoparticles from ZIF‐67 without a silica template, as‐obtained ST‐Co3 O4 shows a good mesoporous environment, provides more active sites, and makes the non‐enzymatic glucose sensor exhibit high sensitivity (2860 μA mM −1 cm −2 ) and fast response time (<1 s) over a wide linear glucose concentration range of 1.0–1300.0 μM. Additionally, the ST‐Co3 O4 /CC electrode demonstrates good anti‐interference, high repeatability, and robust stability (>3000 s), which can repeatedly detect the glucose species in real human serum (RSD<9.69 %, n=3), and shows broad prospects in non‐enzymatic sensors. Abstract : Activating the pores : A simple strategy is developed to construct hierarchically porous Co3 O4 embedded into a metal organic framework‐derived, nitrogen‐doped carbon matrix based on the SiO2 template (ST‐Co3 O4 ). The as‐obtained ST‐Co3 O4 shows a good mesoporous environment, provides more active sites, and makes the non‐ enzymatic glucose sensor exhibit a high sensitivity (2860 μA mM −1 cm −2 ) and fast response time (<1 s) in 1.0–1300.0 μM. … (more)
- Is Part Of:
- ChemElectroChem. Volume 8:Issue 5(2021)
- Journal:
- ChemElectroChem
- Issue:
- Volume 8:Issue 5(2021)
- Issue Display:
- Volume 8, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 8
- Issue:
- 5
- Issue Sort Value:
- 2021-0008-0005-0000
- Page Start:
- 812
- Page End:
- 818
- Publication Date:
- 2021-01-29
- Subjects:
- metal-organic framework -- silica spheres -- cobalt oxide -- nitrogen-doped carbon -- glucose sensors
Electrochemistry -- Periodicals
541.37 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/%28ISSN%292196-0216 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/celc.202001588 ↗
- Languages:
- English
- ISSNs:
- 2196-0216
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3133.496200
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16163.xml