Detection and Differentiation of Dural Arteriovenous Fistulas in the Transverse Sinus/Sigmoid Sinus and Cavernous Sinus Using Carotid Ultrasound: Importance of Evaluation of the Occipital Artery. (24th August 2020)
- Record Type:
- Journal Article
- Title:
- Detection and Differentiation of Dural Arteriovenous Fistulas in the Transverse Sinus/Sigmoid Sinus and Cavernous Sinus Using Carotid Ultrasound: Importance of Evaluation of the Occipital Artery. (24th August 2020)
- Main Title:
- Detection and Differentiation of Dural Arteriovenous Fistulas in the Transverse Sinus/Sigmoid Sinus and Cavernous Sinus Using Carotid Ultrasound
- Authors:
- Hisaeda, Emiko
Shimada, Hirofumi
Ogata, Toshiyasu
Fukuda, Kenji
Higashi, Toshio
Inoue, Tooru - Abstract:
- Abstract : Objectives: Dural arteriovenous fistula (DAVFs) in the transverse sinus (TS)/sigmoid sinus (SS) and cavernous sinus (CS) are observed frequently in the clinic. This study aimed to detect DAVFs with ultrasound and compare carotid ultrasound findings between these conditions. Methods: We retrospectively reviewed 26 patients with either a TS/SS DAVF or a CS DAVF who were admitted to our hospital for evaluation of DAVFs from 2014 to 2018. The shunt site decision was made by neuroendovascular experts, whereas carotid ultrasound examinations were performed by ultrasound specialists. The flow velocity of the ipsilateral external carotid artery was reviewed in all 26 patients, whereas that of the occipital artery (OA) was examined in 20 patients. Blood flow velocities were compared between the TS/SS DAVF and CS DAVF groups. Results: The study included 18 patients with a TS/SS DAVF (11 women and 7 men; mean age ± SD, 65.3 ± 18.6 years) and 8 patients with a CS DAVF (7 women and 1 man; mean age, 70.4 ± 9.3 years). Evaluations of feeder arteries on cerebral angiography showed that all patients had dural branches from the internal carotid and middle meningeal arteries as feeders of CS DAVFs, whereas the OA was the major feeder source of all TS/SS DAVF cases. The end‐diastolic velocity (EDV) of the external carotid artery was significantly higher in patients with a TS/SS DAVF compared with those with a CS DAVF ( P = .004). The EDV of the OA was significantly elevated in TS/SSAbstract : Objectives: Dural arteriovenous fistula (DAVFs) in the transverse sinus (TS)/sigmoid sinus (SS) and cavernous sinus (CS) are observed frequently in the clinic. This study aimed to detect DAVFs with ultrasound and compare carotid ultrasound findings between these conditions. Methods: We retrospectively reviewed 26 patients with either a TS/SS DAVF or a CS DAVF who were admitted to our hospital for evaluation of DAVFs from 2014 to 2018. The shunt site decision was made by neuroendovascular experts, whereas carotid ultrasound examinations were performed by ultrasound specialists. The flow velocity of the ipsilateral external carotid artery was reviewed in all 26 patients, whereas that of the occipital artery (OA) was examined in 20 patients. Blood flow velocities were compared between the TS/SS DAVF and CS DAVF groups. Results: The study included 18 patients with a TS/SS DAVF (11 women and 7 men; mean age ± SD, 65.3 ± 18.6 years) and 8 patients with a CS DAVF (7 women and 1 man; mean age, 70.4 ± 9.3 years). Evaluations of feeder arteries on cerebral angiography showed that all patients had dural branches from the internal carotid and middle meningeal arteries as feeders of CS DAVFs, whereas the OA was the major feeder source of all TS/SS DAVF cases. The end‐diastolic velocity (EDV) of the external carotid artery was significantly higher in patients with a TS/SS DAVF compared with those with a CS DAVF ( P = .004). The EDV of the OA was significantly elevated in TS/SS DAVF cases compared with CS DAVF cases ( P < .001). Conclusions: Duplex ultrasound parameters are significantly different between patients with TS/SS and CS DAVFs. An increased EDV of the OA can predict the presence of a TS/SS DAVF. … (more)
- Is Part Of:
- Journal of ultrasound in medicine. Volume 40:Number 4(2021)
- Journal:
- Journal of ultrasound in medicine
- Issue:
- Volume 40:Number 4(2021)
- Issue Display:
- Volume 40, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 40
- Issue:
- 4
- Issue Sort Value:
- 2021-0040-0004-0000
- Page Start:
- 683
- Page End:
- 687
- Publication Date:
- 2020-08-24
- Subjects:
- arteriovenous fistula -- cavernous sinus -- duplex Doppler ultrasound -- sigmoid sinus -- transverse sinus -- ultrasound
Ultrasonics in medicine -- Periodicals
Ultrasonics
Ultrasonography
Ultrasonics in medicine
Electronic journals
Periodicals
Periodicals
616.07543 - Journal URLs:
- http://www.jultrasoundmed.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/jum.15438 ↗
- Languages:
- English
- ISSNs:
- 0278-4297
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5071.455000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16142.xml