Topological recovery for non-rigid 2D/3D registration of coronary artery models. (March 2021)
- Record Type:
- Journal Article
- Title:
- Topological recovery for non-rigid 2D/3D registration of coronary artery models. (March 2021)
- Main Title:
- Topological recovery for non-rigid 2D/3D registration of coronary artery models
- Authors:
- Yoon, Siyeop
Yoon, Chang Hwan
Lee, Deukhee - Abstract:
- Highlights: The 2D-3D registration visualizes the distal part of coronary artery occlusion. The 2D-3D registration recovers the topology of 2D centerlines. The trimmed chamfer distance improves the robustness of the registration algorithm. The multi-threaded particle swarm optimization and cage based 3D deformation enable to speed up the optimization process. Abstract: Background and Objective: Intra-operative X-ray angiography, the current standard method for visualizing and diagnosing cardiovascular disease, is limited in its ability to provide essential 3D information. These limitations are disadvantages in treating patients. For example, it is a cause of lowering the success rate of interventional procedures. Here, we propose a novel 2D-3D non-rigid registration method to understand vascular geometry during percutaneous coronary intervention. Methods: The proposed method uses the local bijection pair distance as a cost function to minimize the effect of inconsistencies from center-line extraction. Moreover, novel cage-based 3D deformation and multi-threaded particle swarm optimization are utilized to implement real-time registration. We evaluated the proposed method for 154 examinations from 10 anonymous patients by coverage percentage, comparing the average distance of the 2D extracted center-line with that of the registered 3D center-line. Results: The proposed 2D-3D non-rigid registration method achieved an average distance of 1.98 mm with a 0.54 s computation time.Highlights: The 2D-3D registration visualizes the distal part of coronary artery occlusion. The 2D-3D registration recovers the topology of 2D centerlines. The trimmed chamfer distance improves the robustness of the registration algorithm. The multi-threaded particle swarm optimization and cage based 3D deformation enable to speed up the optimization process. Abstract: Background and Objective: Intra-operative X-ray angiography, the current standard method for visualizing and diagnosing cardiovascular disease, is limited in its ability to provide essential 3D information. These limitations are disadvantages in treating patients. For example, it is a cause of lowering the success rate of interventional procedures. Here, we propose a novel 2D-3D non-rigid registration method to understand vascular geometry during percutaneous coronary intervention. Methods: The proposed method uses the local bijection pair distance as a cost function to minimize the effect of inconsistencies from center-line extraction. Moreover, novel cage-based 3D deformation and multi-threaded particle swarm optimization are utilized to implement real-time registration. We evaluated the proposed method for 154 examinations from 10 anonymous patients by coverage percentage, comparing the average distance of the 2D extracted center-line with that of the registered 3D center-line. Results: The proposed 2D-3D non-rigid registration method achieved an average distance of 1.98 mm with a 0.54 s computation time. Additionally, in aiming to reduce the uncertainty of XA images, we used the proposed method to retrospectively visualize the connections between 2D vascular segments and the distal part of occlusions. Conclusions: Ultimately, the proposed 2D/3D non-rigid registration method can successfully register the 3D center-line of coronary arteries with corresponding 2D XA images, and is computationally sufficient for online usage. Therefore, this method can improve the success rate of such procedures as a percutaneous coronary intervention and provide the information necessary to diagnose cardiovascular diseases better. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 200(2021)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 200(2021)
- Issue Display:
- Volume 200, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 200
- Issue:
- 2021
- Issue Sort Value:
- 2021-0200-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-03
- Subjects:
- Arteries -- Angiography -- Non-rigid registration -- 2D-3D registration -- Chronic total occlusion -- Deformable models -- Particle swarm optimization
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105922 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16105.xml