DDD mode-switching and loss of atrioventricular synchrony evokes heart failure: A rare but possible trigger of pacing-induced cardiomyopathy. Issue 4 (April 2021)
- Record Type:
- Journal Article
- Title:
- DDD mode-switching and loss of atrioventricular synchrony evokes heart failure: A rare but possible trigger of pacing-induced cardiomyopathy. Issue 4 (April 2021)
- Main Title:
- DDD mode-switching and loss of atrioventricular synchrony evokes heart failure: A rare but possible trigger of pacing-induced cardiomyopathy
- Authors:
- Aoyama, Daisetsu
Mukai, Moe
Kaseno, Kenichi
Tsuji, Toshihiko
Sakakibara, Keiichi
Hasegawa, Kanae
Nodera, Minoru
Miyazaki, Shinsuke
Uzui, Hiroyasu
Tada, Hiroshi - Abstract:
- Abstract: Pacing-induced cardiomyopathy (PICM), defined as left ventricular dysfunction, occurs in the setting of chronic, high burden right ventricular pacing. We describe an unusual case of PICM. A 64-year-old man underwent a medical check-up and was diagnosed with complete atrioventricular block (AVB) with regular and slow ventricular contractions at 38 beats/min (bpm). The patient underwent a pacemaker implantation with a dual-chamber pacing (DDD) pacemaker. This patient had no symptoms or signs of PICM during complete AVB or the period after undergoing dual-chamber pacing. However, PICM developed within a short time after the onset of atrial flutter (AFL). During AFL, the automatic mode switch of the DDD pacemaker to the DDIR mode worked normally, and the ventricles were paced with a stable and regular rate (60 bpm). Despite the administration of ß-blockers and diuretics, his symptoms and status did not improve. After the elimination of the AFL and restoration of AV synchrony with a DDD mode by catheter ablation, the deteriorated condition rapidly improved. In this patient, the coexistence of the loss of AV synchrony and high burden RV pacing during AFL might have caused this unusual PICM. Learning objective: Even when patients have no symptoms or signs of pacing-induced cardiomyopathy (PICM) during complete atrioventricular block or the period after undergoing dual-chamber pacing, automatic mode-switching to the DDI mode during atrial tachyarrhythmias could rapidlyAbstract: Pacing-induced cardiomyopathy (PICM), defined as left ventricular dysfunction, occurs in the setting of chronic, high burden right ventricular pacing. We describe an unusual case of PICM. A 64-year-old man underwent a medical check-up and was diagnosed with complete atrioventricular block (AVB) with regular and slow ventricular contractions at 38 beats/min (bpm). The patient underwent a pacemaker implantation with a dual-chamber pacing (DDD) pacemaker. This patient had no symptoms or signs of PICM during complete AVB or the period after undergoing dual-chamber pacing. However, PICM developed within a short time after the onset of atrial flutter (AFL). During AFL, the automatic mode switch of the DDD pacemaker to the DDIR mode worked normally, and the ventricles were paced with a stable and regular rate (60 bpm). Despite the administration of ß-blockers and diuretics, his symptoms and status did not improve. After the elimination of the AFL and restoration of AV synchrony with a DDD mode by catheter ablation, the deteriorated condition rapidly improved. In this patient, the coexistence of the loss of AV synchrony and high burden RV pacing during AFL might have caused this unusual PICM. Learning objective: Even when patients have no symptoms or signs of pacing-induced cardiomyopathy (PICM) during complete atrioventricular block or the period after undergoing dual-chamber pacing, automatic mode-switching to the DDI mode during atrial tachyarrhythmias could rapidly cause PICM. PICM could occur with a much more rapid time course than the historical model of PICM where cardiomyopathy may take several years to develop. Much attention should be paid during the follow-up to patients receiving DDD pacemakers to avoid any unusual PICM as in this case. … (more)
- Is Part Of:
- Journal of cardiology cases. Volume 23:Issue 4(2021)
- Journal:
- Journal of cardiology cases
- Issue:
- Volume 23:Issue 4(2021)
- Issue Display:
- Volume 23, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 23
- Issue:
- 4
- Issue Sort Value:
- 2021-0023-0004-0000
- Page Start:
- 158
- Page End:
- 162
- Publication Date:
- 2021-04
- Subjects:
- Pacing-induced cardiomyopathy -- Heart failure -- Pacemaker -- Atrioventricular block -- Atrial flutter -- Catheter ablation
Cardiology -- Periodicals
Cardiovascular Diseases -- Case Reports
Cardiovascular Diseases -- Periodicals
Cardiology -- Case Reports
Cardiology -- Periodicals
Cardiology
Electronic journals
Periodicals
616.12 - Journal URLs:
- http://www.sciencedirect.com/science/journal/18785409 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/18785409 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jccase.2020.11.003 ↗
- Languages:
- English
- ISSNs:
- 1878-5409
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16110.xml