How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state?. (March 2021)
- Record Type:
- Journal Article
- Title:
- How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state?. (March 2021)
- Main Title:
- How preconditioning and pretensioning of grafts used in ACLigaments surgical reconstruction are influenced by their mechanical time-dependent characteristics: Can we optimize their initial loading state?
- Authors:
- Marchiori, Gregorio
Lopomo, Nicola Francesco
Bologna, Emanuela
Spadaro, Doriana
Camarda, Lawrence
Berni, Matteo
Visani, Andrea
Zito, Marianna
Zaffagnini, Stefano
Zingales, Massimiliano - Abstract:
- Abstract: Purpose: Consensus about a pre-implant preparation protocol adaptable to any graft used in Anterior Cruciate Ligament reconstruction is still lacking. In fact, there is not agreement on reliable metrics that consider both specific graft dimensional characteristics, such as its diameter, and the inherent properties of its constitutive material, i.e. ligaments or tendons. Aim of the present study was to investigate and propose the applied engineering stress as a possible metrics. Methods: Preconditioning and pretensioning protocol involved groups of grafts with different section (10 or 32 mm 2 ) and materials (i.e. human patellar and hamstring tendons, and synthetic grafts). A 140 N load was applied to the grafts and maintained for 100 s. Initial stress and following stress-relaxation (a mechanical characteristic that can be related to knee laxity) were specifically analysed. Findings: Initial stress, ranging between 4 and 12 MPa, was affected primarily by the graft cross-section area and secondarily by the choice of the graft material. In terms of loss of the initial stress, stress-relaxation behaviour varied instead on a narrower range, namely 13–17%. Interpretation: Engineering stress can be identified as the correct metrics to optimize the initial state of each graft to avoid excessive stiffness, laxity or fatigue rupture phenomena. Highlights: Implement preconditioning/pretensioning protocol, and apply it to for Ligaments reconstruction. Mechanical test onAbstract: Purpose: Consensus about a pre-implant preparation protocol adaptable to any graft used in Anterior Cruciate Ligament reconstruction is still lacking. In fact, there is not agreement on reliable metrics that consider both specific graft dimensional characteristics, such as its diameter, and the inherent properties of its constitutive material, i.e. ligaments or tendons. Aim of the present study was to investigate and propose the applied engineering stress as a possible metrics. Methods: Preconditioning and pretensioning protocol involved groups of grafts with different section (10 or 32 mm 2 ) and materials (i.e. human patellar and hamstring tendons, and synthetic grafts). A 140 N load was applied to the grafts and maintained for 100 s. Initial stress and following stress-relaxation (a mechanical characteristic that can be related to knee laxity) were specifically analysed. Findings: Initial stress, ranging between 4 and 12 MPa, was affected primarily by the graft cross-section area and secondarily by the choice of the graft material. In terms of loss of the initial stress, stress-relaxation behaviour varied instead on a narrower range, namely 13–17%. Interpretation: Engineering stress can be identified as the correct metrics to optimize the initial state of each graft to avoid excessive stiffness, laxity or fatigue rupture phenomena. Highlights: Implement preconditioning/pretensioning protocol, and apply it to for Ligaments reconstruction. Mechanical test on Patellar and Hamstring ligaments about two different values of section. This study provided an important basis about the choice of graft in the treatment of Ligaments injury. … (more)
- Is Part Of:
- Clinical biomechanics. Volume 83(2021)
- Journal:
- Clinical biomechanics
- Issue:
- Volume 83(2021)
- Issue Display:
- Volume 83, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 83
- Issue:
- 2021
- Issue Sort Value:
- 2021-0083-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-03
- Subjects:
- Anterior cruciate ligament -- Graft -- Preconditioning -- Pretensioning -- Stress relaxation
Biomechanics -- Periodicals
Osteopathic medicine -- Periodicals
Biomechanics -- Periodicals
Osteopathic Medicine -- Periodicals
612.76 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02680033 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.clinbiomech.2021.105294 ↗
- Languages:
- English
- ISSNs:
- 0268-0033
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.262800
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16101.xml