Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: A finite element analysis. (March 2021)
- Record Type:
- Journal Article
- Title:
- Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: A finite element analysis. (March 2021)
- Main Title:
- Biomechanical effects of dental implant diameter, connection type, and bone density on microgap formation and fatigue failure: A finite element analysis
- Authors:
- Lee, Hyeonjong
Jo, Minhye
Noh, Gunwoo - Abstract:
- Highlights: l Three-dimensional dental implant finite element models with vertical and oblique loadings l Influence of connection types, implant diameters, and bone densities on microgap formation and fatigue life l Tissue-level connection type-induced low microgap formation and high resistance to fatigue failure ABSTRACT: Background and Objective: Understanding fatigue failure and microgap formation in dental implants, abutments, and screws under various clinical circumstances is clinically meaningful. In this study, these aspects were evaluated based on implant diameter, connection type, and bone density. Methods: Twelve three-dimensional finite element models were constructed by combining two bone densities (low and high), two connection types (bone and tissue levels), and three implant diameters (3.5, 4.0, and 4.5 mm). Each model was composed of cortical and cancellous bone tissues, the nerve canal, and the implant complex. After the screw was preloaded, vertical (100 N) and oblique (200 N) loadings were applied. The relative displacements at the interfaces between implant, abutment, and screw were analyzed. The fatigue lives of the titanium alloy (Ti–6Al–4V) components were calculated through repetitive mastication simulations. Mann–Whitney U and Kruskal–Wallis one-way tests were performed on the 50 highest displacement values of each model. Results: At the implant/abutment interface, large microgaps were observed under oblique loading in the buccal direction. At theHighlights: l Three-dimensional dental implant finite element models with vertical and oblique loadings l Influence of connection types, implant diameters, and bone densities on microgap formation and fatigue life l Tissue-level connection type-induced low microgap formation and high resistance to fatigue failure ABSTRACT: Background and Objective: Understanding fatigue failure and microgap formation in dental implants, abutments, and screws under various clinical circumstances is clinically meaningful. In this study, these aspects were evaluated based on implant diameter, connection type, and bone density. Methods: Twelve three-dimensional finite element models were constructed by combining two bone densities (low and high), two connection types (bone and tissue levels), and three implant diameters (3.5, 4.0, and 4.5 mm). Each model was composed of cortical and cancellous bone tissues, the nerve canal, and the implant complex. After the screw was preloaded, vertical (100 N) and oblique (200 N) loadings were applied. The relative displacements at the interfaces between implant, abutment, and screw were analyzed. The fatigue lives of the titanium alloy (Ti–6Al–4V) components were calculated through repetitive mastication simulations. Mann–Whitney U and Kruskal–Wallis one-way tests were performed on the 50 highest displacement values of each model. Results: At the implant/abutment interface, large microgaps were observed under oblique loading in the buccal direction. At the abutment/screw interface, microgap formation increased along the implant diameter under vertical loading but decreased under oblique loading (p < 0.001); the largest microgap formation occurred in the lingual direction. In all cases, the bone-level connection induced larger microgap formation than the tissue-level connections. Moreover, only the bone-level connection models showed fatigue failure, and the minimum fatigue life was observed for the implant diameter of 3.5 mm. Conclusions: Tissue-level implants possess biomechanical advantages compared to bone-level ones. Two-piece implants with diameters below 3.5 mm should be avoided in the posterior mandibular area. … (more)
- Is Part Of:
- Computer methods and programs in biomedicine. Volume 200(2021)
- Journal:
- Computer methods and programs in biomedicine
- Issue:
- Volume 200(2021)
- Issue Display:
- Volume 200, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 200
- Issue:
- 2021
- Issue Sort Value:
- 2021-0200-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-03
- Subjects:
- Dental implant -- microgap -- fatigue failure -- finite element analysis
IAI implant/abutment interface -- FEM finite element analysis -- IT internal tissue-level -- IB internal bone-level
Medicine -- Computer programs -- Periodicals
Biology -- Computer programs -- Periodicals
Computers -- Periodicals
Medicine -- Periodicals
Médecine -- Logiciels -- Périodiques
Biologie -- Logiciels -- Périodiques
Biology -- Computer programs
Medicine -- Computer programs
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01692607 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.cmpb.2020.105863 ↗
- Languages:
- English
- ISSNs:
- 0169-2607
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3394.095000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16105.xml