Blood-based host biomarker diagnostics in active case finding for pulmonary tuberculosis: A diagnostic case-control study. (March 2021)
- Record Type:
- Journal Article
- Title:
- Blood-based host biomarker diagnostics in active case finding for pulmonary tuberculosis: A diagnostic case-control study. (March 2021)
- Main Title:
- Blood-based host biomarker diagnostics in active case finding for pulmonary tuberculosis: A diagnostic case-control study
- Authors:
- Moreira, Flora Martinez Figueira
Verma, Renu
Pereira dos Santos, Paulo Cesar
Leite, Alessandra
da Silva Santos, Andrea
de Araujo, Rafaele Carla Pivetta
da Silva, Bruna Oliveira
de Sá Queiroz, Júlio Henrique Ferreira
Persing, David H.
Södersten, Erik
Gnanashanmugam, Devasena
Khatri, Purvesh
Croda, Julio
Andrews, Jason R. - Abstract:
- Abstract: Background: There is a need to identify scalable tuberculosis screening strategies among high burden populations. The WHO has identified a non-sputum-based triage test as a development priority. Methods: We performed a diagnostic case-control study of point-of-care C-reactive protein (CRP) and Prototype-Xpert-MTB-Host-Response (Xpert-MTB-HR) assays in the context of a mass screening program for tuberculosis in two prisons in Brazil. All incarcerated individuals irrespective of symptoms were screened by sputum Xpert MTB/RIF and sputum culture. Among consecutive, Xpert MTB/RIF or culture-confirmed cases and Xpert MTB/RIF and culture-negative controls, CRP was quantified in serum by a point-of-care assay (iChroma-II) and a 3-gene expression score was quantified from whole blood using the Xpert-MTB-HR cartridge. We evaluated receiver operating characteristic area under the curve (AUC) and assessed specificity at 90% sensitivity and sensitivity at 70% specificity, consistent with WHO target product profile (TPP) benchmarks. Findings: Two hundred controls (no TB) and 100 culture- or Xpert MTB/RIF-positive tuberculosis cases were included. Half of tuberculosis cases and 11% of controls reported any tuberculosis symptoms. AUC for CRP was 0·79 (95% CI: 0·73–0·84) and for Xpert-MTB-HR was 0·84 (95% CI: 0·79–0·89). At 90% sensitivity, Xpert-MTB-HR had significantly higher specificity (53·0%, 95% CI: 45·0–69·0%) than CRP (28·1%, 95% CI: 20·2–41·8%) ( p = 0·003), both wellAbstract: Background: There is a need to identify scalable tuberculosis screening strategies among high burden populations. The WHO has identified a non-sputum-based triage test as a development priority. Methods: We performed a diagnostic case-control study of point-of-care C-reactive protein (CRP) and Prototype-Xpert-MTB-Host-Response (Xpert-MTB-HR) assays in the context of a mass screening program for tuberculosis in two prisons in Brazil. All incarcerated individuals irrespective of symptoms were screened by sputum Xpert MTB/RIF and sputum culture. Among consecutive, Xpert MTB/RIF or culture-confirmed cases and Xpert MTB/RIF and culture-negative controls, CRP was quantified in serum by a point-of-care assay (iChroma-II) and a 3-gene expression score was quantified from whole blood using the Xpert-MTB-HR cartridge. We evaluated receiver operating characteristic area under the curve (AUC) and assessed specificity at 90% sensitivity and sensitivity at 70% specificity, consistent with WHO target product profile (TPP) benchmarks. Findings: Two hundred controls (no TB) and 100 culture- or Xpert MTB/RIF-positive tuberculosis cases were included. Half of tuberculosis cases and 11% of controls reported any tuberculosis symptoms. AUC for CRP was 0·79 (95% CI: 0·73–0·84) and for Xpert-MTB-HR was 0·84 (95% CI: 0·79–0·89). At 90% sensitivity, Xpert-MTB-HR had significantly higher specificity (53·0%, 95% CI: 45·0–69·0%) than CRP (28·1%, 95% CI: 20·2–41·8%) ( p = 0·003), both well below the TPP benchmark of 70%. Among individuals with medium or high sputum Xpert MTB/RIF semi-quantitative load, sensitivity (at 70% specificity) of CRP (90·3%, 95% CI: 74·2–98·0) and Xpert-MTB-HR (96·8%, 95% CI: 83·3–99·9%) was higher. Interpretation: For active case finding in this high tuberculosis-burden setting, CRP and Xpert-MTB-HR did not meet TPP benchmarks for a triage test. However, Xpert-MTB-HR was highly sensitive in detecting individuals with medium or high sputum bacillary burden. Funding: National Institutes of Health (R01 AI130058 and R01 AI149620) and Brazilian National Council for Scientific and Technological Development (CNPq-404182/2019-4). … (more)
- Is Part Of:
- EClinicalMedicine. Volume 33(2021)
- Journal:
- EClinicalMedicine
- Issue:
- Volume 33(2021)
- Issue Display:
- Volume 33, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 33
- Issue:
- 2021
- Issue Sort Value:
- 2021-0033-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-03
- Subjects:
- Tuberculosis -- Diagnostic -- Host response -- Biomarker -- Triage -- Active case finding
Medicine -- Research -- Periodicals
Medical policy -- Periodicals
Clinical Medicine
Health Policy
Public Health
Medical policy
Medicine -- Research
Periodical
Electronic journals
Periodicals
613 - Journal URLs:
- https://www.sciencedirect.com/science/journal/25895370 ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.eclinm.2021.100776 ↗
- Languages:
- English
- ISSNs:
- 2589-5370
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16103.xml