Improved Reliability of Automated ASPECTS Evaluation Using Iterative Model Reconstruction from Head CT Scans. Issue 2 (9th January 2021)
- Record Type:
- Journal Article
- Title:
- Improved Reliability of Automated ASPECTS Evaluation Using Iterative Model Reconstruction from Head CT Scans. Issue 2 (9th January 2021)
- Main Title:
- Improved Reliability of Automated ASPECTS Evaluation Using Iterative Model Reconstruction from Head CT Scans
- Authors:
- Löffler, Maximilian T.
Sollmann, Nico
Mönch, Sebastian
Friedrich, Benjamin
Zimmer, Claus
Baum, Thomas
Maegerlein, Christian
Kirschke, Jan S. - Abstract:
- ABSTRACT: BACKGROUND AND PURPOSE: Iterative model reconstruction (IMR) has shown to improve computed tomography (CT) image quality compared to hybrid iterative reconstruction (HIR). Alberta Stroke Program Early CT Score (ASPECTS) assessment in early stroke is particularly dependent on high‐image quality. Purpose of this study was to investigate the reliability of ASPECTS assessed by humans and software based on HIR and IMR, respectively. METHODS: Forty‐seven consecutive patients with acute anterior circulation large vessel occlusions (LVOs) and successful endovascular thrombectomy were included. ASPECTS was assessed by three neuroradiologists (one attending, two residents) and by automated software in noncontrast axial CT with HIR (iDose4; 5 mm) and IMR (5 and 0.9 mm). Two expert neuroradiologists determined consensus ASPECTS reading using all available image data including MRI. Agreement between four raters (three humans, one software) and consensus were compared using square‐weighted kappa ( κ ). RESULTS: Human raters achieved moderate to almost perfect agreement ( κ = .557‐.845) with consensus reading. The attending showed almost perfect agreement for 5 mm HIR ( κ HIR = .845), while residents had mostly substantial agreements without clear trends across reconstructions. Software had substantial to almost perfect agreement with consensus, increasing with IMR 5 and 0.9 mm slice thickness ( κ HIR = .751, κ IMR = .777, and κ IMR0.9 = .814). Agreements inversely declinedABSTRACT: BACKGROUND AND PURPOSE: Iterative model reconstruction (IMR) has shown to improve computed tomography (CT) image quality compared to hybrid iterative reconstruction (HIR). Alberta Stroke Program Early CT Score (ASPECTS) assessment in early stroke is particularly dependent on high‐image quality. Purpose of this study was to investigate the reliability of ASPECTS assessed by humans and software based on HIR and IMR, respectively. METHODS: Forty‐seven consecutive patients with acute anterior circulation large vessel occlusions (LVOs) and successful endovascular thrombectomy were included. ASPECTS was assessed by three neuroradiologists (one attending, two residents) and by automated software in noncontrast axial CT with HIR (iDose4; 5 mm) and IMR (5 and 0.9 mm). Two expert neuroradiologists determined consensus ASPECTS reading using all available image data including MRI. Agreement between four raters (three humans, one software) and consensus were compared using square‐weighted kappa ( κ ). RESULTS: Human raters achieved moderate to almost perfect agreement ( κ = .557‐.845) with consensus reading. The attending showed almost perfect agreement for 5 mm HIR ( κ HIR = .845), while residents had mostly substantial agreements without clear trends across reconstructions. Software had substantial to almost perfect agreement with consensus, increasing with IMR 5 and 0.9 mm slice thickness ( κ HIR = .751, κ IMR = .777, and κ IMR0.9 = .814). Agreements inversely declined for these reconstructions for the attending ( κ HIR = .845, κ IMR = .763, and κ IMR0.9 = .681). CONCLUSIONS: Human and software rating showed good reliability of ASPECTS across different CT reconstructions. Human raters performed best with the reconstruction algorithms they had most experience with (HIR for the attending). Automated software benefits from higher resolution with better contrasts in IMR with 0.9 mm slice thickness. … (more)
- Is Part Of:
- Journal of neuroimaging. Volume 31:Issue 2(2021)
- Journal:
- Journal of neuroimaging
- Issue:
- Volume 31:Issue 2(2021)
- Issue Display:
- Volume 31, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 31
- Issue:
- 2
- Issue Sort Value:
- 2021-0031-0002-0000
- Page Start:
- 341
- Page End:
- 347
- Publication Date:
- 2021-01-09
- Subjects:
- Cerebrovascular disease and stroke -- computer‐assisted image analysis -- iterative image reconstruction -- middle cerebral artery infarction -- multidetector computed tomography
Diagnostic imaging -- Periodicals
Nervous system -- Diseases -- Diagnosis -- Periodicals
Imagerie pour le diagnostic -- Périodiques
Système nerveux -- Maladies -- Diagnostic -- Périodiques
Imagerie médicale
Neuroimagerie
Neurologie
Système nerveux
Périodique électronique (Descripteur de forme)
Ressource Internet (Descripteur de forme)
616.804754 - Journal URLs:
- http://jon.sagepub.com/ ↗
http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1552-6569 ↗
http://www.ingentaconnect.com/content/bpl/jon ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1111/jon.12810 ↗
- Languages:
- English
- ISSNs:
- 1051-2284
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5021.548000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16126.xml