Difference in ambient-personal exposure to PM2.5 and its inflammatory effect in local residents in urban and peri-urban Beijing, China: results of the AIRLESS project. (9th December 2020)
- Record Type:
- Journal Article
- Title:
- Difference in ambient-personal exposure to PM2.5 and its inflammatory effect in local residents in urban and peri-urban Beijing, China: results of the AIRLESS project. (9th December 2020)
- Main Title:
- Difference in ambient-personal exposure to PM2.5 and its inflammatory effect in local residents in urban and peri-urban Beijing, China: results of the AIRLESS project
- Authors:
- Han, Yiqun
Chatzidiakou, Lia
Yan, Li
Chen, Wu
Zhang, Hanbin
Krause, Anika
Xue, Tao
Chan, Queenie
Liu, Jing
Wu, Yangfeng
Barratt, Ben
Jones, Rod
Zhu, Tong
Kelly, Frank J. - Abstract:
- Abstract : We quantified and compared the personal and ambient exposure to PM2.5 and the related health impact among residents in Beijing, China. Abstract : Measurement of ambient fine particulate matter (PM2.5 ) is often used as a proxy of personal exposure in epidemiological studies. However, the difference between personal and ambient exposure, and whether it biases the estimates of health effects remain unknown. Based on an epidemiological study (AIRLESS) and simultaneously launched intensive monitoring campaigns (APHH), we quantified and compared the personal and ambient exposure to PM2.5 and the related health impact among residents in Beijing, China. In total, 123 urban and 128 peri-urban non-smoking participants were recruited from two well-established cohorts in Beijing. During winter 2016 and summer 2017, each participant was instructed to carry a validated personal air monitor (PAM) to measure PM2.5 concentration at high spatiotemporal resolution for seven consecutive days in each season. Multiple inflammatory biomarkers were measured, including exhaled NO, blood monocytes counts and C-reactive protein. Linear mixed-effect models were used for the associations between exposure and health outcomes with adjustment for confounders. The average level of daily personal exposure to PM2.5 was consistently lower than using corresponding ambient concentration, and the difference is greater during the winter. The personal to ambient (P/A) ratio of exposure to PM2.5Abstract : We quantified and compared the personal and ambient exposure to PM2.5 and the related health impact among residents in Beijing, China. Abstract : Measurement of ambient fine particulate matter (PM2.5 ) is often used as a proxy of personal exposure in epidemiological studies. However, the difference between personal and ambient exposure, and whether it biases the estimates of health effects remain unknown. Based on an epidemiological study (AIRLESS) and simultaneously launched intensive monitoring campaigns (APHH), we quantified and compared the personal and ambient exposure to PM2.5 and the related health impact among residents in Beijing, China. In total, 123 urban and 128 peri-urban non-smoking participants were recruited from two well-established cohorts in Beijing. During winter 2016 and summer 2017, each participant was instructed to carry a validated personal air monitor (PAM) to measure PM2.5 concentration at high spatiotemporal resolution for seven consecutive days in each season. Multiple inflammatory biomarkers were measured, including exhaled NO, blood monocytes counts and C-reactive protein. Linear mixed-effect models were used for the associations between exposure and health outcomes with adjustment for confounders. The average level of daily personal exposure to PM2.5 was consistently lower than using corresponding ambient concentration, and the difference is greater during the winter. The personal to ambient (P/A) ratio of exposure to PM2.5 exhibited an exponentially declining trend, and showed larger variations when ambient PM2.5 levels < 25 μg m −3 . Personal exposure to PM2.5 was significantly associated with the increase in respiratory and systemic inflammatory biomarkers; however, the associations were weaker or became insignificant when ambient concentrations were used. Exposure to ambient PM2.5 might not be a good proxy to estimate the health effect of exposure to personal PM2.5 . … (more)
- Is Part Of:
- Faraday discussions. Volume 226(2020)
- Journal:
- Faraday discussions
- Issue:
- Volume 226(2020)
- Issue Display:
- Volume 226, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 226
- Issue:
- 2020
- Issue Sort Value:
- 2020-0226-2020-0000
- Page Start:
- 569
- Page End:
- 583
- Publication Date:
- 2020-12-09
- Subjects:
- Chemistry -- Periodicals
Metallurgy -- Periodicals
Electrochemistry -- Periodicals
540 - Journal URLs:
- http://pubs.rsc.org/en/journals/journalissues/fd#!issueid=fd016192&type=current&issnprint=1359-6640 ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0fd00097c ↗
- Languages:
- English
- ISSNs:
- 1359-6640
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3866.900000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16072.xml