Assessment of a circular powered stapler for creation of anastomosis in left-sided colorectal surgery: A prospective cohort study. (December 2020)
- Record Type:
- Journal Article
- Title:
- Assessment of a circular powered stapler for creation of anastomosis in left-sided colorectal surgery: A prospective cohort study. (December 2020)
- Main Title:
- Assessment of a circular powered stapler for creation of anastomosis in left-sided colorectal surgery: A prospective cohort study
- Authors:
- Herzig, Daniel O.
Ogilvie, James W.
Chudzinski, Allen
Ferrara, Andrea
Ashraf, Shazad Q.
Jimenez-Rodriguez, Rosa M.
Van der Speeten, Kurt
Kinross, James
Schimmelpenning, Hendrik
Sagar, Peter M.
Cannon, Jamie A.
Schwiers, Michael L.
Singleton, David W.
Waggoner, Jason R.
Fryrear, Raymond
Sylla, Patricia - Abstract:
- Abstract: Background: Circular staplers perform a critical function for creation of anastomoses in colorectal surgeries. Powered stapling systems allow for reduced force required by surgeons to fire the device and may provide advantages for creating a secure anastomosis. The objective of this study was to evaluate the clinical performance of a novel circular powered stapler in a post-market setting, during left-sided colectomy procedures. Materials and methods: Consecutive subjects underwent left-sided colorectal resections that included anastomosis performed with the ECHELON CIRCULAR™ Powered Stapler (ECP). The primary endpoint was the frequency in which a stapler performance issue was observed. Secondary endpoints included evaluation of ease of use of the device via a surgeon satisfaction questionnaire, and monitoring/recording of procedure-related adverse events (AEs). Results: A total of 168 anastomoses were performed with the ECP. Surgical approaches included robotic-assisted (n = 74, 44.0%), laparoscopic (n = 71, 42.3%), open (n = 20, 11.9%), and hand-assisted minimally invasive (n = 3, 1.8%) procedures. There were 22 occurrences of device performance issues in 20 (11.9%) subjects during surgery. No positive intraoperative leak tests were observed, and only 1 issue was related to a procedure-related AE or surgical complication, which was an instance of incomplete surgical donut necessitating re-anastomosis. Postoperative anastomotic leaks were experienced in 4 (2.4%)Abstract: Background: Circular staplers perform a critical function for creation of anastomoses in colorectal surgeries. Powered stapling systems allow for reduced force required by surgeons to fire the device and may provide advantages for creating a secure anastomosis. The objective of this study was to evaluate the clinical performance of a novel circular powered stapler in a post-market setting, during left-sided colectomy procedures. Materials and methods: Consecutive subjects underwent left-sided colorectal resections that included anastomosis performed with the ECHELON CIRCULAR™ Powered Stapler (ECP). The primary endpoint was the frequency in which a stapler performance issue was observed. Secondary endpoints included evaluation of ease of use of the device via a surgeon satisfaction questionnaire, and monitoring/recording of procedure-related adverse events (AEs). Results: A total of 168 anastomoses were performed with the ECP. Surgical approaches included robotic-assisted (n = 74, 44.0%), laparoscopic (n = 71, 42.3%), open (n = 20, 11.9%), and hand-assisted minimally invasive (n = 3, 1.8%) procedures. There were 22 occurrences of device performance issues in 20 (11.9%) subjects during surgery. No positive intraoperative leak tests were observed, and only 1 issue was related to a procedure-related AE or surgical complication, which was an instance of incomplete surgical donut necessitating re-anastomosis. Postoperative anastomotic leaks were experienced in 4 (2.4%) subjects. Clavien-Dindo classification of all AEs indicated that 92.0% were Grades I or II. Participating surgeons rated the ECP as easier to use compared to previously used manual circular staplers in 85.7% of procedures. Conclusion: The circular powered stapler exhibited few clinically relevant performance issues, an overall favorable safety profile, and ease of use for creation of left-sided colon anastomoses. Highlights: Test device performance issues occurred in 20 (11.9%) subjects with only one issue requiring surgical revision. There were zero (0%) intraoperative leaks and 4 (2.4%) postoperative anastomotic leaks among 168 procedures. The circular powered stapler demonstrated ease of use as judged by investigators. … (more)
- Is Part Of:
- International journal of surgery. Volume 84(2020)
- Journal:
- International journal of surgery
- Issue:
- Volume 84(2020)
- Issue Display:
- Volume 84, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 84
- Issue:
- 2020
- Issue Sort Value:
- 2020-0084-2020-0000
- Page Start:
- 140
- Page End:
- 146
- Publication Date:
- 2020-12
- Subjects:
- Circular stapler -- Anastomotic leak -- Powered stapler -- Colorectal -- Anastomosis -- Colectomy
Surgery -- Periodicals
Surgical Procedures, Operative -- Periodicals
617.005 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17439191 ↗
http://ees.elsevier.com/ijs/ ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijsu.2020.11.001 ↗
- Languages:
- English
- ISSNs:
- 1743-9191
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.685050
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16050.xml