Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response. (28th January 2021)
- Record Type:
- Journal Article
- Title:
- Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response. (28th January 2021)
- Main Title:
- Reduction in the QRS area after cardiac resynchronization therapy is associated with survival and echocardiographic response
- Authors:
- Ghossein, Mohammed A.
van Stipdonk, Antonius M. W.
Plesinger, Filip
Kloosterman, Mariëlle
Wouters, Philippe C.
Salden, Odette A. E.
Meine, Mathias
Maass, Alexander H.
Prinzen, Frits W.
Vernooy, Kevin - Abstract:
- Abstract: Introduction: Recent studies have shown that the baseline QRS area is associated with the clinical response after cardiac resynchronization therapy (CRT). In this study, we investigated the association of QRS area reduction (∆QRS area) after CRT with the outcome. We hypothesize that a larger ∆QRS area is associated with a better survival and echocardiographic response. Methods and Results: Electrocardiograms (ECG) obtained before and 2–12 months after CRT from 1299 patients in a multi‐center CRT‐registry were analyzed. The QRS area was calculated from vectorcardiograms that were synthesized from 12‐lead ECGs. The primary endpoint was a combination of all‐cause mortality, heart transplantation, and left ventricular (LV) assist device implantation. The secondary endpoint was the echocardiographic response, defined as LV end‐systolic volume reduction ≥ of 15%. Patients with ∆QRS area above the optimal cut‐off value (62 µVs) had a lower risk of reaching the primary endpoint (hazard ratio: 0.43; confidence interval [CI] 0.33–0.56, p < .001), and a higher chance of echocardiographic response (odds ratio [OR] 3.3;CI 2.4–4.6, p < .0001). In multivariable analysis, ∆QRS area was independently associated with both endpoints. In patients with baseline QRS area ≥109 µVs, survival, and echocardiographic response were better when the ∆QRS area was ≥62 µVs ( p < .0001). Logistic regression showed that in patients with baseline QRS area ≥109 µVs, ∆QRS area was the onlyAbstract: Introduction: Recent studies have shown that the baseline QRS area is associated with the clinical response after cardiac resynchronization therapy (CRT). In this study, we investigated the association of QRS area reduction (∆QRS area) after CRT with the outcome. We hypothesize that a larger ∆QRS area is associated with a better survival and echocardiographic response. Methods and Results: Electrocardiograms (ECG) obtained before and 2–12 months after CRT from 1299 patients in a multi‐center CRT‐registry were analyzed. The QRS area was calculated from vectorcardiograms that were synthesized from 12‐lead ECGs. The primary endpoint was a combination of all‐cause mortality, heart transplantation, and left ventricular (LV) assist device implantation. The secondary endpoint was the echocardiographic response, defined as LV end‐systolic volume reduction ≥ of 15%. Patients with ∆QRS area above the optimal cut‐off value (62 µVs) had a lower risk of reaching the primary endpoint (hazard ratio: 0.43; confidence interval [CI] 0.33–0.56, p < .001), and a higher chance of echocardiographic response (odds ratio [OR] 3.3;CI 2.4–4.6, p < .0001). In multivariable analysis, ∆QRS area was independently associated with both endpoints. In patients with baseline QRS area ≥109 µVs, survival, and echocardiographic response were better when the ∆QRS area was ≥62 µVs ( p < .0001). Logistic regression showed that in patients with baseline QRS area ≥109 µVs, ∆QRS area was the only significant predictor of survival (OR: 0.981; CI: 0.967–0.994, p = .006). Conclusion: ∆QRS area is an independent determinant of CRT response, especially in patients with a large baseline QRS area. Failure to achieve a large QRS area reduction with CRT is associated with a poor clinical outcome. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 3(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 3(2021)
- Issue Display:
- Volume 32, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2021-0032-0003-0000
- Page Start:
- 813
- Page End:
- 822
- Publication Date:
- 2021-01-28
- Subjects:
- cardiac resynchronization therapy -- echocardiographic response -- heart failure -- QRS area -- QRS area reduction -- survival
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14910 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 16025.xml