Head and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting. (January 2021)
- Record Type:
- Journal Article
- Title:
- Head and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting. (January 2021)
- Main Title:
- Head and neck IMPT probabilistic dose accumulation: Feasibility of a 2 mm setup uncertainty setting
- Authors:
- Wagenaar, Dirk
Kierkels, Roel G.J.
van der Schaaf, Arjen
Meijers, Arturs
Scandurra, Daniel
Sijtsema, Nanna M.
Korevaar, Erik W.
Steenbakkers, Roel J.H.M.
Knopf, Antje C.
Langendijk, Johannes A.
Both, Stefan - Abstract:
- Highlights: Probabilistic dose accumulation was performed for ten IMPT head and neck cancer. Comparisons were made between different setup and range uncertainty settings. A setup uncertainty setting of 2 mm was found to give sufficient target coverage. Abstract: Objective: To establish optimal robust optimization uncertainty settings for clinical head and neck cancer (HNC) patients undergoing 3D image-guided pencil beam scanning (PBS) proton therapy. Methods: We analyzed ten consecutive HNC patients treated with 70 and 54.25 GyRBE to the primary and prophylactic clinical target volumes (CTV) respectively using intensity-modulated proton therapy (IMPT). Clinical plans were generated using robust optimization with 5 mm/3% setup/range uncertainties (RayStation v6.1). Additional plans were created for 4, 3, 2 and 1 mm setup and 3% range uncertainty and for 3 mm setup and 3%, 2% and 1% range uncertainty. Systematic and random error distributions were determined for setup and range uncertainties based on our quality assurance program. From these, 25 treatment scenarios were sampled for each plan, each consisting of a systematic setup and range error and daily random setup errors. Fraction doses were calculated on the weekly verification CT closest to the date of treatment as this was considered representative of the daily patient anatomy. Results: Plans with a 2 mm/3% setup/range uncertainty setting adequately covered the primary and prophylactic CTV (V95 ≥ 99% in 98.8% and 90.8%Highlights: Probabilistic dose accumulation was performed for ten IMPT head and neck cancer. Comparisons were made between different setup and range uncertainty settings. A setup uncertainty setting of 2 mm was found to give sufficient target coverage. Abstract: Objective: To establish optimal robust optimization uncertainty settings for clinical head and neck cancer (HNC) patients undergoing 3D image-guided pencil beam scanning (PBS) proton therapy. Methods: We analyzed ten consecutive HNC patients treated with 70 and 54.25 GyRBE to the primary and prophylactic clinical target volumes (CTV) respectively using intensity-modulated proton therapy (IMPT). Clinical plans were generated using robust optimization with 5 mm/3% setup/range uncertainties (RayStation v6.1). Additional plans were created for 4, 3, 2 and 1 mm setup and 3% range uncertainty and for 3 mm setup and 3%, 2% and 1% range uncertainty. Systematic and random error distributions were determined for setup and range uncertainties based on our quality assurance program. From these, 25 treatment scenarios were sampled for each plan, each consisting of a systematic setup and range error and daily random setup errors. Fraction doses were calculated on the weekly verification CT closest to the date of treatment as this was considered representative of the daily patient anatomy. Results: Plans with a 2 mm/3% setup/range uncertainty setting adequately covered the primary and prophylactic CTV (V95 ≥ 99% in 98.8% and 90.8% of the treatment scenarios respectively). The average organ-at-risk dose decreased with 1.1 GyRBE /mm setup uncertainty reduction and 0.5 GyRBE /1% range uncertainty reduction. Normal tissue complication probabilities decreased by 2.0%/mm setup uncertainty reduction and by 0.9%/1% range uncertainty reduction. Conclusion: The results of this study indicate that margin reduction below 3 mm/3% is possible but requires a larger cohort to substantiate clinical introduction. … (more)
- Is Part Of:
- Radiotherapy and oncology. Volume 154(2021)
- Journal:
- Radiotherapy and oncology
- Issue:
- Volume 154(2021)
- Issue Display:
- Volume 154, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 154
- Issue:
- 2021
- Issue Sort Value:
- 2021-0154-2021-0000
- Page Start:
- 45
- Page End:
- 52
- Publication Date:
- 2021-01
- Subjects:
- Head and neck cancer -- Proton therapy -- IMPT -- Robust optimization
Oncology -- Periodicals
Radiotherapy -- Periodicals
Tumors -- Periodicals
Medical Oncology -- Periodicals
Neoplasms -- radiotherapy -- Periodicals
Radiotherapy -- Periodicals
Radiothérapie -- Périodiques
Cancérologie -- Périodiques
Tumeurs -- Périodiques
Electronic journals
616.9940642 - Journal URLs:
- http://www.sciencedirect.com/science/journal/01678140 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/01678140 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/01678140 ↗
http://www.estro.org/ ↗
http://www.elsevier.com/journals ↗
http://www.journals.elsevier.com/radiotherapy-and-oncology/ ↗ - DOI:
- 10.1016/j.radonc.2020.09.001 ↗
- Languages:
- English
- ISSNs:
- 0167-8140
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 7240.790000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16006.xml