Physiological system analysis of the kidney by high‐temporal‐resolution T2∗ monitoring of an oxygenation step response. Issue 1 (25th July 2020)
- Record Type:
- Journal Article
- Title:
- Physiological system analysis of the kidney by high‐temporal‐resolution T2∗ monitoring of an oxygenation step response. Issue 1 (25th July 2020)
- Main Title:
- Physiological system analysis of the kidney by high‐temporal‐resolution T2∗ monitoring of an oxygenation step response
- Authors:
- Zhao, Kaixuan
Pohlmann, Andreas
Feng, Qijian
Mei, Yingjie
Yang, Guixiang
Yi, Peiwei
Feng, Qianjin
Chen, Wufang
Zhou, Lili
Wu, Ed X.
Seeliger, Erdmann
Niendorf, Thoralf
Feng, Yanqiu - Abstract:
- Abstract : Purpose: Examine the feasibility of characterizing the regulation of renal oxygenation using high‐temporal‐resolution monitoring of the T 2 ∗ response to a step‐like oxygenation stimulus. Methods: For T 2 ∗ mapping, multi‐echo gradient‐echo imaging was used (temporal resolution = 9 seconds). A step‐like renal oxygenation challenge was applied involving sequential exposure to hyperoxia (100% O2 ), hypoxia (10% O2 + 90% N2 ), and hyperoxia (100% O2 ). In vivo experiments were performed in healthy rats (N = 10) and in rats with bilateral ischemia‐reperfusion injury (N = 4). To assess the step response of renal oxygenation, a second‐order exponential model was used (model parameters: amplitude [ A ], time delay [Δ t ], damping constant [ D ], and period of the oscillation [ T ]) for renal cortex, outer stripe of the outer medulla, inner stripe of the outer medulla, and inner medulla. Results: The second‐order exponential model permitted us to model the exponential T 2 ∗ recovery and the superimposed T 2 ∗ oscillation following renal oxygenation stimulus. The in vivo experiments revealed a difference in Douter medulla between healthy controls ( D < 1, indicating oscillatory recovery) and ischemia‐reperfusion injury ( D > 1, reflecting aperiodic recovery). The increase in Douter medulla by a factor of 3.7 (outer stripe of the outer medulla) and 10.0 (inner stripe of the outer medulla) suggests that this parameter might be rather sensitive to (patho)physiologicalAbstract : Purpose: Examine the feasibility of characterizing the regulation of renal oxygenation using high‐temporal‐resolution monitoring of the T 2 ∗ response to a step‐like oxygenation stimulus. Methods: For T 2 ∗ mapping, multi‐echo gradient‐echo imaging was used (temporal resolution = 9 seconds). A step‐like renal oxygenation challenge was applied involving sequential exposure to hyperoxia (100% O2 ), hypoxia (10% O2 + 90% N2 ), and hyperoxia (100% O2 ). In vivo experiments were performed in healthy rats (N = 10) and in rats with bilateral ischemia‐reperfusion injury (N = 4). To assess the step response of renal oxygenation, a second‐order exponential model was used (model parameters: amplitude [ A ], time delay [Δ t ], damping constant [ D ], and period of the oscillation [ T ]) for renal cortex, outer stripe of the outer medulla, inner stripe of the outer medulla, and inner medulla. Results: The second‐order exponential model permitted us to model the exponential T 2 ∗ recovery and the superimposed T 2 ∗ oscillation following renal oxygenation stimulus. The in vivo experiments revealed a difference in Douter medulla between healthy controls ( D < 1, indicating oscillatory recovery) and ischemia‐reperfusion injury ( D > 1, reflecting aperiodic recovery). The increase in Douter medulla by a factor of 3.7 (outer stripe of the outer medulla) and 10.0 (inner stripe of the outer medulla) suggests that this parameter might be rather sensitive to (patho)physiological oxygenation changes. Conclusion: This study demonstrates the feasibility of monitoring the dynamic oxygenation response of renal tissues to a step‐like oxygenation challenge using high‐temporal‐resolution T 2 ∗ mapping. Our results suggest that the implemented system analysis approach may help to unlock questions regarding regulation of renal oxygenation, with the ultimate goal of providing imaging means for diagnostics and therapy of renal diseases. … (more)
- Is Part Of:
- Magnetic resonance in medicine. Volume 85:Issue 1(2021)
- Journal:
- Magnetic resonance in medicine
- Issue:
- Volume 85:Issue 1(2021)
- Issue Display:
- Volume 85, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 85
- Issue:
- 1
- Issue Sort Value:
- 2021-0085-0001-0000
- Page Start:
- 334
- Page End:
- 345
- Publication Date:
- 2020-07-25
- Subjects:
- BOLD MRI -- hyperoxia -- hypoxia -- kidney -- oxygenation -- step response
Nuclear magnetic resonance -- Periodicals
Electron paramagnetic resonance -- Periodicals
616.07548 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1002/(ISSN)1522-2594 ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/mrm.28399 ↗
- Languages:
- English
- ISSNs:
- 0740-3194
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5337.798000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 16000.xml