Interlaboratory Application of Raman CO2 Densimeter Equations: Experimental Procedure and Statistical Analysis Using Bootstrapped Confidence Intervals. Issue 7 (July 2021)
- Record Type:
- Journal Article
- Title:
- Interlaboratory Application of Raman CO2 Densimeter Equations: Experimental Procedure and Statistical Analysis Using Bootstrapped Confidence Intervals. Issue 7 (July 2021)
- Main Title:
- Interlaboratory Application of Raman CO2 Densimeter Equations: Experimental Procedure and Statistical Analysis Using Bootstrapped Confidence Intervals
- Authors:
- Remigi, Samantha
Mancini, Tullio
Ferrando, Simona
Frezzotti, Maria Luce - Abstract:
- Raman spectroscopy has been used extensively to calculate CO2 fluid density in many geological environments, based on the measurement of the Fermi diad split (Δ; cm –1 ) in the CO2 spectrum. While recent research has allowed the calibration of several Raman CO2 densimeters, there is a limit to the interlaboratory application of published equations. These calculate two classes of density values for the same measured Δ, with a deviation of 0.09 ± 0.02 g/cm 3 on average. To elucidate the influence of experimental parameters on the calibration of Raman CO2 densimeters, we propose a bottom-up approach beginning with the calibration of a new equation, to evaluate a possible instrument-dependent variability induced by experimental conditions. Then, we develop bootstrapped confidence intervals for density estimate of existing equations to move the statistical analysis from a sample-specific to a population level. We find that Raman densimeter equations calibrated based on spectra acquired with similar spectral resolution calculate CO2 density values lying within standard errors of equations and are suitable for the interlaboratory application. The statistical analysis confirms that equations calibrated at similar spectral resolution calculate CO2 densities equivalent at 95% confidence, and each Raman densimeter does have a limit of applicability, statistically defined by a minimum Δ value, below which the error in calculated CO2 densities is too high. Graphical Abstract
- Is Part Of:
- Applied spectroscopy. Volume 75:Issue 7(2021)
- Journal:
- Applied spectroscopy
- Issue:
- Volume 75:Issue 7(2021)
- Issue Display:
- Volume 75, Issue 7 (2021)
- Year:
- 2021
- Volume:
- 75
- Issue:
- 7
- Issue Sort Value:
- 2021-0075-0007-0000
- Page Start:
- 867
- Page End:
- 881
- Publication Date:
- 2021-07
- Subjects:
- Raman spectroscopy -- carbon dioxide -- Raman densimeter equation -- carbon dioxide density -- CO2
Spectrum analysis -- Periodicals
543.505 - Journal URLs:
- http://asp.sagepub.com/ ↗
http://www.ingentaconnect.com/content/sas/sas ↗
http://www.uk.sagepub.com/home.nav ↗
http://firstsearch.oclc.org/journal=0003-7028;screen=info;ECOIP ↗ - DOI:
- 10.1177/0003702820987601 ↗
- Languages:
- English
- ISSNs:
- 0003-7028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15990.xml