Changes in the surface topography and element proportion of clinically failed SLA implants after in vitro debridement by different methods. Issue 3 (10th January 2021)
- Record Type:
- Journal Article
- Title:
- Changes in the surface topography and element proportion of clinically failed SLA implants after in vitro debridement by different methods. Issue 3 (10th January 2021)
- Main Title:
- Changes in the surface topography and element proportion of clinically failed SLA implants after in vitro debridement by different methods
- Authors:
- Tong, Zian
Fu, Renjie
Zhu, Weijun
Shi, Jue
Yu, Mengfei
Si, Misi - Abstract:
- Abstract: Objective: To evaluate the surface topography and element proportion changes in clinically failed implants after different modalities in vitro debridement and to compare the cleaning effect of different method combinations. Material and Methods: Thirty clinical failed implants were treated by different debridement methods in vitro as follows: Group 1: physiologic saline irrigation; Group 2: glycine powder air polishing; Group 3: glycine powder air polishing + ethylenediaminetetraacetic acid (EDTA); Group 4: polyetheretherketone (PEEK) tip ultrasonic scaling; and Group 5: PEEK tip ultrasonic scaling + EDTA. The relative contaminated area reduction (RCAR), visual analogue scale (VAS, the higher value means, the better cleaning effect) and surface roughness were assessed using scanning electron microscopy ( SEM ), stereoscopic microscopy (SM) and white light interferometry (WLI). Surface chemistry was determined by energy dispersive spectroscopy (EDS). Results: Group 4 and Group 5 showed higher RCARs (82.90%, 82.89%), VAS scores (2.61, 2.33) and roughness reductions (−0.85 μm, −1.80 μm). Group 3 attained the highest decrease of C% (carbon, −26.67%), O% (oxygen, −13.71%) and N % (nitrogen, −5.66%), and the highest increase of Ti% (titanium, 49.67%). PEEK remnants were detected on the implant surface of Groups 4 and 5. Conclusion: Within the limitation of the present in vitro design, PEEK tip ultrasonic scaling was more effective in eliminating visible contamination,Abstract: Objective: To evaluate the surface topography and element proportion changes in clinically failed implants after different modalities in vitro debridement and to compare the cleaning effect of different method combinations. Material and Methods: Thirty clinical failed implants were treated by different debridement methods in vitro as follows: Group 1: physiologic saline irrigation; Group 2: glycine powder air polishing; Group 3: glycine powder air polishing + ethylenediaminetetraacetic acid (EDTA); Group 4: polyetheretherketone (PEEK) tip ultrasonic scaling; and Group 5: PEEK tip ultrasonic scaling + EDTA. The relative contaminated area reduction (RCAR), visual analogue scale (VAS, the higher value means, the better cleaning effect) and surface roughness were assessed using scanning electron microscopy ( SEM ), stereoscopic microscopy (SM) and white light interferometry (WLI). Surface chemistry was determined by energy dispersive spectroscopy (EDS). Results: Group 4 and Group 5 showed higher RCARs (82.90%, 82.89%), VAS scores (2.61, 2.33) and roughness reductions (−0.85 μm, −1.80 μm). Group 3 attained the highest decrease of C% (carbon, −26.67%), O% (oxygen, −13.71%) and N % (nitrogen, −5.66%), and the highest increase of Ti% (titanium, 49.67%). PEEK remnants were detected on the implant surface of Groups 4 and 5. Conclusion: Within the limitation of the present in vitro design, PEEK tip ultrasonic scaling was more effective in eliminating visible contamination, while glycine powder air polishing combined with EDTA treatment was more conducive to expose the original surface element distribution. Both methods have their own advantages in decontamination, but none of them could reconstruct the surface as the pristine implant. … (more)
- Is Part Of:
- Clinical oral implants research. Volume 32:Issue 3(2021)
- Journal:
- Clinical oral implants research
- Issue:
- Volume 32:Issue 3(2021)
- Issue Display:
- Volume 32, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 3
- Issue Sort Value:
- 2021-0032-0003-0000
- Page Start:
- 263
- Page End:
- 273
- Publication Date:
- 2021-01-10
- Subjects:
- air polishing -- decontamination -- dental implants -- ethylenediaminetetraacetic acid -- ultrasonic scaling
Dental implants -- Research -- Periodicals
617.69 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/clr.13697 ↗
- Languages:
- English
- ISSNs:
- 0905-7161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3286.318000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15980.xml