Ellingson, Benjamin M. - Abstract:
- Abstract : Sampling k ‐space asymmetrically (ie, partial Fourier sampling) in the readout direction is a common way to reduce the echo time (TE) during magnetic resonance image acquisitions. This technique requires overlap around the center of k ‐space to provide a calibration region for reconstruction, which limits the minimum fractional echo to ~60% before artifacts are observed. The present study describes a method for reconstructing images from exact half echoes using two separate acquisitions with reversed readout polarity, effectively providing a full line of k ‐space without additional data around central k ‐space. This approach can benefit sequences or applications that prioritize short TE, short inter‐echo spacing or short repetition time. An example of the latter is demonstrated to reduce banding artifacts in balanced steady‐state free precession. Abstract : This study describes a method for reconstructing images from exact half echoes using two acquisitions with reserved readout polarity to effectively provide a full line of k‐space. The approach benefits applications that prioritize short echo time, short inter‐echo spacing or short repetition time. The example shows reduced banding artifacts in balanced steady state free procession (bSSFP).
- Is Part Of:
- NMR in biomedicine. Volume 34:Number 4(2021)
- Journal:
- NMR in biomedicine
- Issue:
- Volume 34:Number 4(2021)
- Issue Display:
- Volume 34, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 34
- Issue:
- 4
- Issue Sort Value:
- 2021-0034-0004-0000
- Page Start:
- n/a
- Page End:
- n/a
- Publication Date:
- 2020-12-09
- Subjects:
- low rank -- partial Fourier
Nuclear magnetic resonance -- Periodicals
Magnetic Resonance Spectroscopy -- Periodicals
574 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1002/nbm.4458 ↗
- Languages:
- English
- ISSNs:
- 0952-3480
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6113.931000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15964.xml