A comparison of Monte Carlo dropout and bootstrap aggregation on the performance and uncertainty estimation in radiation therapy dose prediction with deep learning neural networks. (22nd February 2021)
- Record Type:
- Journal Article
- Title:
- A comparison of Monte Carlo dropout and bootstrap aggregation on the performance and uncertainty estimation in radiation therapy dose prediction with deep learning neural networks. (22nd February 2021)
- Main Title:
- A comparison of Monte Carlo dropout and bootstrap aggregation on the performance and uncertainty estimation in radiation therapy dose prediction with deep learning neural networks
- Authors:
- Nguyen, Dan
Sadeghnejad Barkousaraie, Azar
Bohara, Gyanendra
Balagopal, Anjali
McBeth, Rafe
Lin, Mu-Han
Jiang, Steve - Abstract:
- Abstract: Recently, artificial intelligence technologies and algorithms have become a major focus for advancements in treatment planning for radiation therapy. As these are starting to become incorporated into the clinical workflow, a major concern from clinicians is not whether the model is accurate, but whether the model can express to a human operator when it does not know if its answer is correct. We propose to use Monte Carlo Dropout (MCDO) and the bootstrap aggregation (bagging) technique on deep learning (DL) models to produce uncertainty estimations for radiation therapy dose prediction. We show that both models are capable of generating a reasonable uncertainty map, and, with our proposed scaling technique, creating interpretable uncertainties and bounds on the prediction and any relevant metrics. Performance-wise, bagging provides statistically significant reduced loss value and errors in most of the metrics investigated in this study. The addition of bagging was able to further reduce errors by another 0.34% for D m e a n and 0.19% for D max, on average, when compared to the baseline model. Overall, the bagging framework provided significantly lower mean absolute error (MAE) of 2.62, as opposed to the baseline model's MAE of 2.87. The usefulness of bagging, from solely a performance standpoint, does highly depend on the problem and the acceptable predictive error, and its high upfront computational cost during training should be factored in to deciding whether itAbstract: Recently, artificial intelligence technologies and algorithms have become a major focus for advancements in treatment planning for radiation therapy. As these are starting to become incorporated into the clinical workflow, a major concern from clinicians is not whether the model is accurate, but whether the model can express to a human operator when it does not know if its answer is correct. We propose to use Monte Carlo Dropout (MCDO) and the bootstrap aggregation (bagging) technique on deep learning (DL) models to produce uncertainty estimations for radiation therapy dose prediction. We show that both models are capable of generating a reasonable uncertainty map, and, with our proposed scaling technique, creating interpretable uncertainties and bounds on the prediction and any relevant metrics. Performance-wise, bagging provides statistically significant reduced loss value and errors in most of the metrics investigated in this study. The addition of bagging was able to further reduce errors by another 0.34% for D m e a n and 0.19% for D max, on average, when compared to the baseline model. Overall, the bagging framework provided significantly lower mean absolute error (MAE) of 2.62, as opposed to the baseline model's MAE of 2.87. The usefulness of bagging, from solely a performance standpoint, does highly depend on the problem and the acceptable predictive error, and its high upfront computational cost during training should be factored in to deciding whether it is advantageous to use it. In terms of deployment with uncertainty estimations turned on, both methods offer the same performance time of about 12 s. As an ensemble-based metaheuristic, bagging can be used with existing machine learning architectures to improve stability and performance, and MCDO can be applied to any DL models that have dropout as part of their architecture. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 66:Number 5(2021)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 66:Number 5(2021)
- Issue Display:
- Volume 66, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 66
- Issue:
- 5
- Issue Sort Value:
- 2021-0066-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02-22
- Subjects:
- radiation therapy -- dose prediction -- deep learning -- treatment planning -- uncertainty -- Monte Carlo dropout -- bootstrap aggregation
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/abe04f ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15931.xml