IPEM topical report: guidance on the use of MRI for external beam radiotherapy treatment planning**Note: this work is part of an IPEM working party and work was shared between the group equally. The working party was chaired by Richard Speight. (25th February 2021)
- Record Type:
- Journal Article
- Title:
- IPEM topical report: guidance on the use of MRI for external beam radiotherapy treatment planning**Note: this work is part of an IPEM working party and work was shared between the group equally. The working party was chaired by Richard Speight. (25th February 2021)
- Main Title:
- IPEM topical report: guidance on the use of MRI for external beam radiotherapy treatment planning**Note: this work is part of an IPEM working party and work was shared between the group equally. The working party was chaired by Richard Speight.
- Authors:
- Speight, Richard
Dubec, Michael
Eccles, Cynthia L
George, Ben
Henry, Ann
Herbert, Trina
Johnstone, Robert I
Liney, Gary P
McCallum, Hazel
Schmidt, Maria A - Abstract:
- Abstract: This document gives guidance for multidisciplinary teams within institutions setting up and using an MRI-guided radiotherapy (RT) treatment planning service. It has been written by a multidisciplinary working group from the Institute of Physics and Engineering in Medicine (IPEM). Guidance has come from the experience of the institutions represented in the IPEM working group, in consultation with other institutions, and where appropriate references are given for any relevant legislation, other guidance documentation and information in the literature. Guidance is only given for MRI acquired for external beam RT treatment planning in a CT-based workflow, i.e. when MRI is acquired and registered to CT with the purpose of aiding delineation of target or organ at risk volumes. MRI use for treatment response assessment, MRI-only RT and other RT treatment types such as brachytherapy and gamma radiosurgery are not considered within the scope of this document. The aim was to produce guidance that will be useful for institutions who are setting up and using a dedicated MR scanner for RT (referred to as an MR-sim) and those who will have limited time on an MR scanner potentially managed outside of the RT department, often by radiology. Although not specifically covered in this document, there is an increase in the use of hybrid MRI-linac systems worldwide and brief comments are included to highlight any crossover with the early implementation of this technology. In thisAbstract: This document gives guidance for multidisciplinary teams within institutions setting up and using an MRI-guided radiotherapy (RT) treatment planning service. It has been written by a multidisciplinary working group from the Institute of Physics and Engineering in Medicine (IPEM). Guidance has come from the experience of the institutions represented in the IPEM working group, in consultation with other institutions, and where appropriate references are given for any relevant legislation, other guidance documentation and information in the literature. Guidance is only given for MRI acquired for external beam RT treatment planning in a CT-based workflow, i.e. when MRI is acquired and registered to CT with the purpose of aiding delineation of target or organ at risk volumes. MRI use for treatment response assessment, MRI-only RT and other RT treatment types such as brachytherapy and gamma radiosurgery are not considered within the scope of this document. The aim was to produce guidance that will be useful for institutions who are setting up and using a dedicated MR scanner for RT (referred to as an MR-sim) and those who will have limited time on an MR scanner potentially managed outside of the RT department, often by radiology. Although not specifically covered in this document, there is an increase in the use of hybrid MRI-linac systems worldwide and brief comments are included to highlight any crossover with the early implementation of this technology. In this document, advice is given on introducing a RT workload onto a non-RT-dedicated MR scanner, as well as planning for installation of an MR scanner dedicated for RT. Next, practical guidance is given on the following, in the context of RT planning: training and education for all staff working in and around an MR scanner; RT patient set-up on an MR scanner; MRI sequence optimisation for RT purposes; commissioning and quality assurance (QA) to be performed on an MR scanner; and MRI to CT registration, including commissioning and QA. … (more)
- Is Part Of:
- Physics in medicine & biology. Volume 66:Number 5(2021)
- Journal:
- Physics in medicine & biology
- Issue:
- Volume 66:Number 5(2021)
- Issue Display:
- Volume 66, Issue 5 (2021)
- Year:
- 2021
- Volume:
- 66
- Issue:
- 5
- Issue Sort Value:
- 2021-0066-0005-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02-25
- Subjects:
- MRI -- radiotherapy treatment planning -- guidelines
Biophysics -- Periodicals
Medical physics -- Periodicals
610.153 - Journal URLs:
- http://ioppublishing.org/ ↗
http://iopscience.iop.org/0031-9155 ↗ - DOI:
- 10.1088/1361-6560/abdc30 ↗
- Languages:
- English
- ISSNs:
- 0031-9155
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15931.xml