Accuracy of CT Colonography for Detection of Polypoid and Nonpolypoid Neoplasia by Gastroenterologists and Radiologists: A Nationwide Multicenter Study in Japan. (January 2017)
- Record Type:
- Journal Article
- Title:
- Accuracy of CT Colonography for Detection of Polypoid and Nonpolypoid Neoplasia by Gastroenterologists and Radiologists: A Nationwide Multicenter Study in Japan. (January 2017)
- Main Title:
- Accuracy of CT Colonography for Detection of Polypoid and Nonpolypoid Neoplasia by Gastroenterologists and Radiologists: A Nationwide Multicenter Study in Japan
- Authors:
- Nagata, Koichi
Endo, Shungo
Honda, Tetsuro
Yasuda, Takaaki
Hirayama, Michiaki
Takahashi, Sho
Kato, Takashi
Horita, Shoichi
Furuya, Ken
Kasai, Kenji
Matsumoto, Hiroshi
Kimura, Yoshiki
Utano, Kenichi
Sugimoto, Hideharu
Kato, Hiroyuki
Yamada, Rieko
Yamamichi, Junta
Shimamoto, Takeshi
Ryu, Yasuji
Matsui, Osamu
Kondo, Hitoshi
Doi, Ayako
Abe, Taro
Yamano, Hiro‐o
Takeuchi, Ken
Hanai, Hiroyuki
Saida, Yukihisa
Fukuda, Katsuyuki
Näppi, Janne
Yoshida, Hiroyuki - Abstract:
- Abstract : OBJECTIVES: The objective of this study was to assess prospectively the diagnostic accuracy of computer‐assisted computed tomographic colonography (CTC) in the detection of polypoid (pedunculated or sessile) and nonpolypoid neoplasms and compare the accuracy between gastroenterologists and radiologists. METHODS: This nationwide multicenter prospective controlled trial recruited 1, 257 participants with average or high risk of colorectal cancer at 14 Japanese institutions. Participants had CTC and colonoscopy on the same day. CTC images were interpreted independently by trained gastroenterologists and radiologists. The main outcome was the accuracy of CTC in the detection of neoplasms ≥6 mm in diameter, with colonoscopy results as the reference standard. Detection sensitivities of polypoid vs. nonpolypoid lesions were also evaluated. RESULTS: Of the 1, 257 participants, 1, 177 were included in the final analysis: 42 (3.6%) were at average risk of colorectal cancer, 456 (38.7%) were at elevated risk, and 679 (57.7%) had recent positive immunochemical fecal occult blood tests. The overall per‐participant sensitivity, specificity, and positive and negative predictive values for neoplasms ≥6 mm in diameter were 0.90, 0.93, 0.83, and 0.96, respectively, among gastroenterologists and 0.86, 0.90, 0.76, and 0.95 among radiologists ( P <0.05 for gastroenterologists vs. radiologists). The sensitivity and specificity for neoplasms ≥10 mm in diameter were 0.93 and 0.99 amongAbstract : OBJECTIVES: The objective of this study was to assess prospectively the diagnostic accuracy of computer‐assisted computed tomographic colonography (CTC) in the detection of polypoid (pedunculated or sessile) and nonpolypoid neoplasms and compare the accuracy between gastroenterologists and radiologists. METHODS: This nationwide multicenter prospective controlled trial recruited 1, 257 participants with average or high risk of colorectal cancer at 14 Japanese institutions. Participants had CTC and colonoscopy on the same day. CTC images were interpreted independently by trained gastroenterologists and radiologists. The main outcome was the accuracy of CTC in the detection of neoplasms ≥6 mm in diameter, with colonoscopy results as the reference standard. Detection sensitivities of polypoid vs. nonpolypoid lesions were also evaluated. RESULTS: Of the 1, 257 participants, 1, 177 were included in the final analysis: 42 (3.6%) were at average risk of colorectal cancer, 456 (38.7%) were at elevated risk, and 679 (57.7%) had recent positive immunochemical fecal occult blood tests. The overall per‐participant sensitivity, specificity, and positive and negative predictive values for neoplasms ≥6 mm in diameter were 0.90, 0.93, 0.83, and 0.96, respectively, among gastroenterologists and 0.86, 0.90, 0.76, and 0.95 among radiologists ( P <0.05 for gastroenterologists vs. radiologists). The sensitivity and specificity for neoplasms ≥10 mm in diameter were 0.93 and 0.99 among gastroenterologists and 0.91 and 0.98 among radiologists (not significant for gastroenterologists vs. radiologists). The CTC interpretation time by radiologists was shorter than that by gastroenterologists (9.97 vs. 15.8 min, P <0.05). Sensitivities for pedunculated and sessile lesions exceeded those for flat elevated lesions ≥10 mm in diameter in both groups (gastroenterologists 0.95, 0.92, and 0.68; radiologists: 0.94, 0.87, and 0.61; P <0.05 for polypoid vs. nonpolypoid), although not significant ( P >0.05) for gastroenterologists vs. radiologists. CONCLUSIONS: CTC interpretation by gastroenterologists and radiologists was accurate for detection of polypoid neoplasms, but less so for nonpolypoid neoplasms. Gastroenterologists had a higher accuracy in the detection of neoplasms ≥6 mm than did radiologists, although their interpretation time was longer than that of radiologists. … (more)
- Is Part Of:
- American journal of gastroenterology. Volume 112:Number 1(2017)
- Journal:
- American journal of gastroenterology
- Issue:
- Volume 112:Number 1(2017)
- Issue Display:
- Volume 112, Issue 1 (2017)
- Year:
- 2017
- Volume:
- 112
- Issue:
- 1
- Issue Sort Value:
- 2017-0112-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-01
- Subjects:
- Stomach -- Diseases -- Periodicals
Intestines -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Gastrointestinal Diseases -- Periodicals
Electronic journals
Periodicals
616.33 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0002-9270 ↗
http://www.amjgastro.com/ ↗
http://www.nature.com/ajg/archive/index.html ↗
http://www.sciencedirect.com/science/journal/00029270 ↗
http://www.nature.com/ ↗
http://www3.interscience.wiley.com/journal/117955841/home ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0002-9270;screen=info;ECOIP ↗ - DOI:
- 10.1038/ajg.2016.478 ↗
- Languages:
- English
- ISSNs:
- 0002-9270
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0824.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15930.xml