3D-printed PEEK implant for mandibular defects repair - a new method. (April 2021)
- Record Type:
- Journal Article
- Title:
- 3D-printed PEEK implant for mandibular defects repair - a new method. (April 2021)
- Main Title:
- 3D-printed PEEK implant for mandibular defects repair - a new method
- Authors:
- Kang, Jianfeng
Zhang, Jie
Zheng, Jibao
Wang, Ling
Li, Dichen
Liu, Shuguang - Abstract:
- Abstract: Functional reconstruction of large-size mandibular continuity defect is still a major challenge in the oral and maxillofacial surgery due to the unsatisfactory repair effects and various complications. This study aimed to develop a new functional repair method for mandibular defects combined with 3D-printed polyetheretherketone (PEEK) implant and the free vascularized fibula graft, and evaluated the service performance of the implant under whole masticatory motion. The design criteria and workflows of the mandibular reconstruction were established based on the requirements of safety, functionality, and shape consistency. Both the biomechanical behavior and the mechanobiological property of mandibular reconstruction under various masticatory motion were investigated by the finite element analysis. The maximum von Mises stress of each component was lower than the yield strength of the corresponding material and the safety factor was more than 2.3 times, which indicated the security of the repair method can be guaranteed. Moreover, the actual deformation of the reconstruction model was lower than that of the normal mandible under most clenching tasks, which assured the primary stability. More than 80% of the volume elements in the bone graft can obtain effective mechanical stimulation, which benefited to reduce the risks of bone resorption. Finally, the novel repair method was applied in clinic and good clinical performances have been achieved. Compared with theAbstract: Functional reconstruction of large-size mandibular continuity defect is still a major challenge in the oral and maxillofacial surgery due to the unsatisfactory repair effects and various complications. This study aimed to develop a new functional repair method for mandibular defects combined with 3D-printed polyetheretherketone (PEEK) implant and the free vascularized fibula graft, and evaluated the service performance of the implant under whole masticatory motion. The design criteria and workflows of the mandibular reconstruction were established based on the requirements of safety, functionality, and shape consistency. Both the biomechanical behavior and the mechanobiological property of mandibular reconstruction under various masticatory motion were investigated by the finite element analysis. The maximum von Mises stress of each component was lower than the yield strength of the corresponding material and the safety factor was more than 2.3 times, which indicated the security of the repair method can be guaranteed. Moreover, the actual deformation of the reconstruction model was lower than that of the normal mandible under most clenching tasks, which assured the primary stability. More than 80% of the volume elements in the bone graft can obtain effective mechanical stimulation, which benefited to reduce the risks of bone resorption. Finally, the novel repair method was applied in clinic and good clinical performances have been achieved. Compared with the conventional fibular bone graft for surgical mandibular reconstruction, this study provides excellent safety and stability to accomplish the functional reconstruction and aesthetic restoration of the mandible defect. Graphical abstract: Image 1 Highlights: A new functional repair method for mandibular defects combined with 3D-printed PEEK implant and fibula graft was proposed. The design criteria and workflows of the mandibular defect repair technology were established. Biomechanical properties of the mandible reconstruction model under whole masticatory motion were evaluated. Good functional and cosmetic outcomes for surgical mandibular reconstruction were obtained. … (more)
- Is Part Of:
- Journal of the mechanical behavior of biomedical materials. Volume 116(2021)
- Journal:
- Journal of the mechanical behavior of biomedical materials
- Issue:
- Volume 116(2021)
- Issue Display:
- Volume 116, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 116
- Issue:
- 2021
- Issue Sort Value:
- 2021-0116-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-04
- Subjects:
- Mandibular defects reconstruction -- Customized design -- 3D printing -- Polyether ether ketone (PEEK) -- Biomechanical analysis
Biomedical materials -- Periodicals
Biomedical materials -- Mechanical properties -- Periodicals
Biomedical materials
Biomedical materials -- Mechanical properties
Periodicals
Electronic journals
610.28 - Journal URLs:
- http://www.sciencedirect.com/science/journal/17516161 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jmbbm.2021.104335 ↗
- Languages:
- English
- ISSNs:
- 1751-6161
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5015.809000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15936.xml