Reventing brittle hybrid high-strength reinforced concrete slab collapse due to punching shear using coal flyash substitution, tie wire fiber and polypropylene fiber. Issue 1 (February 2021)
- Record Type:
- Journal Article
- Title:
- Reventing brittle hybrid high-strength reinforced concrete slab collapse due to punching shear using coal flyash substitution, tie wire fiber and polypropylene fiber. Issue 1 (February 2021)
- Main Title:
- Reventing brittle hybrid high-strength reinforced concrete slab collapse due to punching shear using coal flyash substitution, tie wire fiber and polypropylene fiber
- Authors:
- Aulia, T B
Hayati, Y
Idris, Y
Amalia, Z
Handoko, E - Abstract:
- Abstract: Heavy vehicles crossing a bridge could lead in punching shear failure at reinforced concrete deck slab due to highly concentrated axial compressive load from their wheels. This may occur in a very brittle manner and difficult to fix. Effort in improving punching shear capacity of deck slab is with using high-strength concrete and adding fibers into concrete. However, high-strength concretes are not environmentally friendly because using a lot of cement contributing to large CO2 emissions to the atmosphere during its production, therefore coal flyash is used as a part of cement substitution. Based on these facts, this research aims to analyze punching shear capacity of hybrid high-strength reinforced concrete slabs using coal flyash as cement substitution which added with tie wire fiber and polypropylene fiber. The amount of coal flyash was taken 15% from cement weight as cement substitution, tie wire fiber 2% from concrete volume having aspect ratio l/d of 40 and straight shaped fiber geometry, as well as polypropylene fiber 0.2% from concrete volume. Three hybrid high-strength reinforced concrete slabs of 60 × 60 cm 2 (two-way-slab) with a thickness 12 cm, w/c-ratio of 0.30 and concrete cylinder compressive strength of f′c = 60 MPa were made with 15% coal flyash and 2% tie wire fiber (CFA-TWF), 15% coal flyash and 0.2% polypropylene fiber (CFA-PPF), as well as 15% coal flyash and combination of 2% tie wire fiber and 0.2% polypropylene fiber (CFA-TWF-PPF). OneAbstract: Heavy vehicles crossing a bridge could lead in punching shear failure at reinforced concrete deck slab due to highly concentrated axial compressive load from their wheels. This may occur in a very brittle manner and difficult to fix. Effort in improving punching shear capacity of deck slab is with using high-strength concrete and adding fibers into concrete. However, high-strength concretes are not environmentally friendly because using a lot of cement contributing to large CO2 emissions to the atmosphere during its production, therefore coal flyash is used as a part of cement substitution. Based on these facts, this research aims to analyze punching shear capacity of hybrid high-strength reinforced concrete slabs using coal flyash as cement substitution which added with tie wire fiber and polypropylene fiber. The amount of coal flyash was taken 15% from cement weight as cement substitution, tie wire fiber 2% from concrete volume having aspect ratio l/d of 40 and straight shaped fiber geometry, as well as polypropylene fiber 0.2% from concrete volume. Three hybrid high-strength reinforced concrete slabs of 60 × 60 cm 2 (two-way-slab) with a thickness 12 cm, w/c-ratio of 0.30 and concrete cylinder compressive strength of f′c = 60 MPa were made with 15% coal flyash and 2% tie wire fiber (CFA-TWF), 15% coal flyash and 0.2% polypropylene fiber (CFA-PPF), as well as 15% coal flyash and combination of 2% tie wire fiber and 0.2% polypropylene fiber (CFA-TWF-PPF). One plain slab without flyash and fibers (PSHSC) was tested as a comparison. To guarantee the punching shear failure mechanism, the slabs were reinforced with tensile reinforcement of 10 Ø 10.5 mm which was distributed to each direction and tested then by giving a concentrated punching load. The results showed that using of coal flyash substitution and addition of fibers could significantly increase the punching shear capacity and structural ductility of hybrid high-strength concrete slabs with the highest enhance both achieved in CFA-TWF-PPF, i.e., 67.91% for punching shear capacity and 92.82% for structural ductility compared with plain slab PSHSC. … (more)
- Is Part Of:
- IOP conference series. Volume 1087:Issue 1(2021)
- Journal:
- IOP conference series
- Issue:
- Volume 1087:Issue 1(2021)
- Issue Display:
- Volume 1087, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 1087
- Issue:
- 1
- Issue Sort Value:
- 2021-1087-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02
- Subjects:
- Materials science -- Periodicals
620.1105 - Journal URLs:
- http://iopscience.iop.org/1757-899X ↗
http://ioppublishing.org/ ↗ - DOI:
- 10.1088/1757-899X/1087/1/012039 ↗
- Languages:
- English
- ISSNs:
- 1757-8981
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15908.xml