Development of a Mechanistic Hypothesis Linking Compensatory Biomechanics and Stepping Asymmetry during Gait of Transfemoral Amputees. (3rd February 2019)
- Record Type:
- Journal Article
- Title:
- Development of a Mechanistic Hypothesis Linking Compensatory Biomechanics and Stepping Asymmetry during Gait of Transfemoral Amputees. (3rd February 2019)
- Main Title:
- Development of a Mechanistic Hypothesis Linking Compensatory Biomechanics and Stepping Asymmetry during Gait of Transfemoral Amputees
- Authors:
- Mohamed, Abeer
Sexton, Andrew
Simonsen, Kirsten
McGibbon, Chris A. - Other Names:
- Karamanidis Kiros Academic Editor.
- Abstract:
- Abstract : Objective . Gait asymmetry is a common adaptation observed in lower-extremity amputees, but the underlying mechanisms that explain this gait behavior remain unclear for amputees that use above-knee prostheses. Our objective was to develop a working hypothesis to explain chronic stepping asymmetry in otherwise healthy amputees that use above-knee prostheses. Methods . Two amputees (both through-knee; one with microprocessor knee, one with hydraulic knee) and fourteen control subjects participated. 3D kinematics and kinetics were acquired at normal, fast, and slow walking speeds. Data were analyzed for the push-off and collision limbs during a double support phase. We examined gait parameters to identify the stepping asymmetry then examined the external work rate (centre of mass) and internal (joint) power profiles to formulate a working hypothesis to mechanistically explain the observed stepping asymmetry. Results . Stepping asymmetry at all three gait speeds in amputees was characterized by increased stance phase duration of the intact limb versus relatively normal stance phase duration for the prosthesis limb. The prosthesis limb contributed very little to positive and negative work during the double support phase of gait. To compensate, the intact leg at heel strike first provided aid to the deficient prosthetic ankle/foot during its push-off by doing positive work with the intact knee, which caused a delayed stance phase pattern. The resulting delay in toe-offAbstract : Objective . Gait asymmetry is a common adaptation observed in lower-extremity amputees, but the underlying mechanisms that explain this gait behavior remain unclear for amputees that use above-knee prostheses. Our objective was to develop a working hypothesis to explain chronic stepping asymmetry in otherwise healthy amputees that use above-knee prostheses. Methods . Two amputees (both through-knee; one with microprocessor knee, one with hydraulic knee) and fourteen control subjects participated. 3D kinematics and kinetics were acquired at normal, fast, and slow walking speeds. Data were analyzed for the push-off and collision limbs during a double support phase. We examined gait parameters to identify the stepping asymmetry then examined the external work rate (centre of mass) and internal (joint) power profiles to formulate a working hypothesis to mechanistically explain the observed stepping asymmetry. Results . Stepping asymmetry at all three gait speeds in amputees was characterized by increased stance phase duration of the intact limb versus relatively normal stance phase duration for the prosthesis limb. The prosthesis limb contributed very little to positive and negative work during the double support phase of gait. To compensate, the intact leg at heel strike first provided aid to the deficient prosthetic ankle/foot during its push-off by doing positive work with the intact knee, which caused a delayed stance phase pattern. The resulting delay in toe-off of the intact limb then facilitated the energy transfer from the more robust intact push-off limb to the weaker colliding prosthesis side. This strategy was observed for both amputees. Conclusions . There is a sound scientific rationale for a mechanistic hypothesis that stepping asymmetry in amputee participants is a result of a motor adaptation that is both facilitating the lower-leg trajectory enforced by the prosthesis while compensating for the lack of work done by the prosthesis, the cost of which is increased energy expenditure of the intact knee and both hips. … (more)
- Is Part Of:
- Applied bionics and biomechanics. Volume 2019(2019)
- Journal:
- Applied bionics and biomechanics
- Issue:
- Volume 2019(2019)
- Issue Display:
- Volume 2019, Issue 2019 (2019)
- Year:
- 2019
- Volume:
- 2019
- Issue:
- 2019
- Issue Sort Value:
- 2019-2019-2019-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-02-03
- Subjects:
- Bionics -- Periodicals
Biomechanics -- Periodicals
Biomedical engineering -- Periodicals
003.505 - Journal URLs:
- http://www.tandfonline.com/loi/tbob20 ↗
https://www.hindawi.com/journals/abb/ ↗
http://www.atypon-link.com/WHP/loi/abib ↗
http://www.informaworld.com/smpp/title~content=t778164488~db=all ↗ - DOI:
- 10.1155/2019/4769242 ↗
- Languages:
- English
- ISSNs:
- 1176-2322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1571.911000
British Library HMNTS - ELD Digital store - Ingest File:
- 15896.xml