Optical Enhancement of Exoskeleton-Based Estimation of Glenohumeral Angles. (15th June 2016)
- Record Type:
- Journal Article
- Title:
- Optical Enhancement of Exoskeleton-Based Estimation of Glenohumeral Angles. (15th June 2016)
- Main Title:
- Optical Enhancement of Exoskeleton-Based Estimation of Glenohumeral Angles
- Authors:
- Cortés, Camilo
Unzueta, Luis
de los Reyes-Guzmán, Ana
Ruiz, Oscar E.
Flórez, Julián - Other Names:
- Wang Qining Academic Editor.
- Abstract:
- Abstract : In Robot-Assisted Rehabilitation (RAR) the accurate estimation of the patient limb joint angles is critical for assessing therapy efficacy. In RAR, the use of classic motion capture systems (MOCAPs) (e.g., optical and electromagnetic) to estimate the Glenohumeral (GH) joint angles is hindered by the exoskeleton body, which causes occlusions and magnetic disturbances. Moreover, the exoskeleton posture does not accurately reflect limb posture, as their kinematic models differ. To address the said limitations in posture estimation, we propose installing the cameras of an optical marker-based MOCAP in the rehabilitation exoskeleton. Then, the GH joint angles are estimated by combining the estimated marker poses and exoskeleton Forward Kinematics. Such hybrid system prevents problems related to marker occlusions, reduced camera detection volume, and imprecise joint angle estimation due to the kinematic mismatch of the patient and exoskeleton models. This paper presents the formulation, simulation, and accuracy quantification of the proposed method with simulated human movements. In addition, a sensitivity analysis of the method accuracy to marker position estimation errors, due to system calibration errors and marker drifts, has been carried out. The results show that, even with significant errors in the marker position estimation, method accuracy is adequate for RAR.
- Is Part Of:
- Applied bionics and biomechanics. Volume 2016(2016)
- Journal:
- Applied bionics and biomechanics
- Issue:
- Volume 2016(2016)
- Issue Display:
- Volume 2016, Issue 2016 (2016)
- Year:
- 2016
- Volume:
- 2016
- Issue:
- 2016
- Issue Sort Value:
- 2016-2016-2016-0000
- Page Start:
- Page End:
- Publication Date:
- 2016-06-15
- Subjects:
- Bionics -- Periodicals
Biomechanics -- Periodicals
Biomedical engineering -- Periodicals
003.505 - Journal URLs:
- http://www.tandfonline.com/loi/tbob20 ↗
https://www.hindawi.com/journals/abb/ ↗
http://www.atypon-link.com/WHP/loi/abib ↗
http://www.informaworld.com/smpp/title~content=t778164488~db=all ↗ - DOI:
- 10.1155/2016/5058171 ↗
- Languages:
- English
- ISSNs:
- 1176-2322
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 1571.911000
British Library HMNTS - ELD Digital store - Ingest File:
- 15884.xml