Incidence of pacing‐induced cardiomyopathy in pacemaker‐dependent patients is lower with leadless pacemakers compared to transvenous pacemakers. (25th November 2020)
- Record Type:
- Journal Article
- Title:
- Incidence of pacing‐induced cardiomyopathy in pacemaker‐dependent patients is lower with leadless pacemakers compared to transvenous pacemakers. (25th November 2020)
- Main Title:
- Incidence of pacing‐induced cardiomyopathy in pacemaker‐dependent patients is lower with leadless pacemakers compared to transvenous pacemakers
- Authors:
- Sanchez, Reynaldo
Nadkarni, Anish
Buck, Benjamin
Daoud, Georges
Koppert, Tanner
Okabe, Toshimasa
Houmsse, Mahmoud
Weiss, Raul
Augostini, Ralph
Hummel, John D.
Kalbfleisch, Steven
Daoud, Emile G.
Afzal, Muhammad R. - Abstract:
- Abstract: Introduction: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing‐induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long‐term outcomes of PICM in LP and TVP patients. Methods: The study comprised all pacemaker‐dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long‐term outcomes after cardiac resynchronization (CRT) were assessed in both groups. Results: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow‐up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP ( p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. Conclusion:Abstract: Introduction: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing‐induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long‐term outcomes of PICM in LP and TVP patients. Methods: The study comprised all pacemaker‐dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long‐term outcomes after cardiac resynchronization (CRT) were assessed in both groups. Results: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow‐up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP ( p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. Conclusion: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker‐dependent patients. Age and TVP as pacing modality were predictors for PICM. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 2(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 2(2021)
- Issue Display:
- Volume 32, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2021-0032-0002-0000
- Page Start:
- 477
- Page End:
- 483
- Publication Date:
- 2020-11-25
- Subjects:
- atrioventricular node ablation -- leadless pacemaker -- pacing‐induced cardiomyopathy -- right ventricular pacing -- transvenous pacemaker
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14814 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15868.xml