FMEA occurrence values for four failure modes occurring using look‐up tables for dose calculations. Issue 2 (15th November 2020)
- Record Type:
- Journal Article
- Title:
- FMEA occurrence values for four failure modes occurring using look‐up tables for dose calculations. Issue 2 (15th November 2020)
- Main Title:
- FMEA occurrence values for four failure modes occurring using look‐up tables for dose calculations
- Authors:
- Nelson, Geoff
Paxton, Adam
Kunz, Jeremy
Huang, Jessica
Szegedi, Martin
Sarkar, Vikren
Salter, Bill - Abstract:
- Abstract: Purpose: For a number of different treatment types [such as Total Body Irradiation (TBI), etc.] most institutions utilize tables from commissioned databooks to perform the dose calculations. Each time one manually looks up data from a large table and then copies the numbers for a manual calculation, there is potential for errors. While a second check effectively mitigates the potential error from such calculations, information regarding the frequency and nature of such mistakes is important to develop protocols and workflows that avoid related errors. Methods: Five years' worth of TBI calculations were reviewed. Each calculation was re‐performed and evaluated against the original calculation and original second check. Any discrepancies were noted and those discrepancies were checked to see if the number was the result of misreading from the look‐up table, a typo, copying/skipping partially redundant steps, or rounding/avoiding interpolation. The number of calculations that contained these various types of discrepancies was tallied and percentages representing the frequency of said discrepancies were derived. Results: All of the discrepancies only resulted in a monitor unit (MU) calculation difference of <1.7%. Typos, looking up wrong values from tables, rounding/avoiding interpolation, and skipping steps occurred in 10.4% ( ± 3.1%), 6.3% ( ± 2.5%), 53.1% ( ± 5.1%), and 4.2% ( ± 2.0%) of MU calculations, respectively. Conclusions: While all of the discrepancies onlyAbstract: Purpose: For a number of different treatment types [such as Total Body Irradiation (TBI), etc.] most institutions utilize tables from commissioned databooks to perform the dose calculations. Each time one manually looks up data from a large table and then copies the numbers for a manual calculation, there is potential for errors. While a second check effectively mitigates the potential error from such calculations, information regarding the frequency and nature of such mistakes is important to develop protocols and workflows that avoid related errors. Methods: Five years' worth of TBI calculations were reviewed. Each calculation was re‐performed and evaluated against the original calculation and original second check. Any discrepancies were noted and those discrepancies were checked to see if the number was the result of misreading from the look‐up table, a typo, copying/skipping partially redundant steps, or rounding/avoiding interpolation. The number of calculations that contained these various types of discrepancies was tallied and percentages representing the frequency of said discrepancies were derived. Results: All of the discrepancies only resulted in a monitor unit (MU) calculation difference of <1.7%. Typos, looking up wrong values from tables, rounding/avoiding interpolation, and skipping steps occurred in 10.4% ( ± 3.1%), 6.3% ( ± 2.5%), 53.1% ( ± 5.1%), and 4.2% ( ± 2.0%) of MU calculations, respectively. Conclusions: While all of the discrepancies only resulted in a monitor unit (MU) calculation difference of <1.7%, this review shows how frequently various discrepancies can occur. Typos and rounding/avoiding interpolation are the steps most likely to potentially cause a miscalculation of MU. To avoid direct human interaction on such a large repetitive scale, creating forms that calculate MU automatically from initial measurement data would reduce the incidences that numbers are written/transcribed and eliminate the need to look up data in a table, thus reducing the chance for error. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 2(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 2(2021)
- Issue Display:
- Volume 22, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 2
- Issue Sort Value:
- 2021-0022-0002-0000
- Page Start:
- 9
- Page End:
- 12
- Publication Date:
- 2020-11-15
- Subjects:
- FMEA
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13091 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15869.xml