Permanent His bundle pacing using a new tridimensional delivery sheath and a standard active fixation pacing lead: The telescopic technique. (19th January 2021)
- Record Type:
- Journal Article
- Title:
- Permanent His bundle pacing using a new tridimensional delivery sheath and a standard active fixation pacing lead: The telescopic technique. (19th January 2021)
- Main Title:
- Permanent His bundle pacing using a new tridimensional delivery sheath and a standard active fixation pacing lead: The telescopic technique
- Authors:
- Zingarini, Gianluca
Notaristefano, Francesco
Spighi, Lorenzo
Bagliani, Giuseppe
Cavallini, Claudio - Abstract:
- Abstract: Introduction: Permanent His bundle pacing (PHBP) preserves physiological ventricular activation but technical difficulties have limited its widespread use. We report the first experience of PHBP performed with a new specific delivery sheath (Selectra 3D, Biotronik, Berlin, Germany) and an extendable‐retractable active screw, stylet‐driven pacing lead (Solia S 60, Biotronik). Methods and Results: Clinical, procedural, ECG, and electrical data from consecutive patients undergoing PHBP with this system were collected at implantation, and follow‐up was performed after 1 month. Our cohort included 17 patients (71% males; mean age 76 ± 8 years) undergoing permanent pacing for sick sinus syndrome (59%) or atrioventricular block (41%). PHBP was successful in 15 (88%) procedures with mean procedure and fluoroscopy times of 63 ± 14 and 13 ± 5 min, respectively. The pacing threshold was 2.1 ± 1.1 V @1 ms and the sensed R‐wave amplitude was 5.6 ± 3.5 mV; bipolar and unipolar pacing impedances were 526 ± 115 and 369 ± 109 Ω, respectively. At discharge, neither procedure‐related complications nor lead dislodgement or pacing capture failures was reported. After 1 month, 14 (93%) patients still demonstrated His bundle stimulation and one (7%) lost His bundle capture but the lead revision was not necessary because the myocardial pacing threshold was stable. Follow‐up threshold (2 ± 1.1 vs. 2.3 ± 1.2 V@1 ms, p = .239) and sensed R‐wave amplitude (5.6 ± 3.4 vs. 6.4 ± 2.5, p = .403)Abstract: Introduction: Permanent His bundle pacing (PHBP) preserves physiological ventricular activation but technical difficulties have limited its widespread use. We report the first experience of PHBP performed with a new specific delivery sheath (Selectra 3D, Biotronik, Berlin, Germany) and an extendable‐retractable active screw, stylet‐driven pacing lead (Solia S 60, Biotronik). Methods and Results: Clinical, procedural, ECG, and electrical data from consecutive patients undergoing PHBP with this system were collected at implantation, and follow‐up was performed after 1 month. Our cohort included 17 patients (71% males; mean age 76 ± 8 years) undergoing permanent pacing for sick sinus syndrome (59%) or atrioventricular block (41%). PHBP was successful in 15 (88%) procedures with mean procedure and fluoroscopy times of 63 ± 14 and 13 ± 5 min, respectively. The pacing threshold was 2.1 ± 1.1 V @1 ms and the sensed R‐wave amplitude was 5.6 ± 3.5 mV; bipolar and unipolar pacing impedances were 526 ± 115 and 369 ± 109 Ω, respectively. At discharge, neither procedure‐related complications nor lead dislodgement or pacing capture failures was reported. After 1 month, 14 (93%) patients still demonstrated His bundle stimulation and one (7%) lost His bundle capture but the lead revision was not necessary because the myocardial pacing threshold was stable. Follow‐up threshold (2 ± 1.1 vs. 2.3 ± 1.2 V@1 ms, p = .239) and sensed R‐wave amplitude (5.6 ± 3.4 vs. 6.4 ± 2.5, p = .403) was unchanged compared to the acute phase. Conclusion: PHBP performed with a standard active fixation pacing lead and a new delivery sheath for His pacing is feasible, safe and demonstrates clinically acceptable electric performance both at implantation and after 1 month. … (more)
- Is Part Of:
- Journal of cardiovascular electrophysiology. Volume 32:Number 2(2021)
- Journal:
- Journal of cardiovascular electrophysiology
- Issue:
- Volume 32:Number 2(2021)
- Issue Display:
- Volume 32, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 32
- Issue:
- 2
- Issue Sort Value:
- 2021-0032-0002-0000
- Page Start:
- 449
- Page End:
- 457
- Publication Date:
- 2021-01-19
- Subjects:
- cardiac implantable electrical device -- delivery sheath -- His bundle pacing -- pacemaker -- pacing lead
Blood vessels -- Physiology -- Periodicals
Electrophysiology -- Periodicals
Heart -- Physiology -- Periodicals
612.1 - Journal URLs:
- http://onlinelibrary.wiley.com/ ↗
- DOI:
- 10.1111/jce.14869 ↗
- Languages:
- English
- ISSNs:
- 1045-3873
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.866000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15868.xml