Differentiation of pulmonary sclerosing pneumocytoma from solid malignant pulmonary nodules by radiomic analysis on multiphasic CT. Issue 2 (28th December 2020)
- Record Type:
- Journal Article
- Title:
- Differentiation of pulmonary sclerosing pneumocytoma from solid malignant pulmonary nodules by radiomic analysis on multiphasic CT. Issue 2 (28th December 2020)
- Main Title:
- Differentiation of pulmonary sclerosing pneumocytoma from solid malignant pulmonary nodules by radiomic analysis on multiphasic CT
- Authors:
- Ni, Xiao‐Qiong
Yin, Hong‐kun
Fan, Guo‐hua
Shi, Dai
Xu, Liang
Jin, Dan - Abstract:
- Abstract: Purpose: To investigate the diagnostic value and feasibility of radiomics‐based texture analysis in differentiating pulmonary sclerosing pneumocytoma (PSP) from solid malignant pulmonary nodules (SMPN) on single‐ and three‐phase computed tomography (CT) images. Materials and Methods: A total of 25 PSP patients and 35 SMPN patients with pathologically confirmed results were retrospectively included in this study. For each patient, the tumor regions were manually labeled in images acquired at the noncontrast phase (NCP), arterial phase (AP), and venous phase (VP). The least absolute shrinkage and selection operator (LASSO) method was used to select the most useful predictive features extracted from the CT images. The predictive models that discriminate PSP from SMPN based on single‐phase CT images (NCP, AP, and VP) or three‐phase CT images (Combined model) were developed and validated through fivefold cross‐validation using a logistic regression classifier. Model performance was evaluated using receiver operating characteristic (ROC) analysis. The predictive performance was also compared between the Combined model and human readers. Results: Four, five, and five features were selected from NCP, AP, and VP CT images for the development of radiomic models, respectively. The NCP, AP, and VP models exhibited areas under the curve (AUCs) of 0.748 (95% confidence interval [CI], 0.620–0.852), 0.749 (95% CI, 0.620–0.852), and 0.790 (95% CI, 0.665–0.884) in the validationAbstract: Purpose: To investigate the diagnostic value and feasibility of radiomics‐based texture analysis in differentiating pulmonary sclerosing pneumocytoma (PSP) from solid malignant pulmonary nodules (SMPN) on single‐ and three‐phase computed tomography (CT) images. Materials and Methods: A total of 25 PSP patients and 35 SMPN patients with pathologically confirmed results were retrospectively included in this study. For each patient, the tumor regions were manually labeled in images acquired at the noncontrast phase (NCP), arterial phase (AP), and venous phase (VP). The least absolute shrinkage and selection operator (LASSO) method was used to select the most useful predictive features extracted from the CT images. The predictive models that discriminate PSP from SMPN based on single‐phase CT images (NCP, AP, and VP) or three‐phase CT images (Combined model) were developed and validated through fivefold cross‐validation using a logistic regression classifier. Model performance was evaluated using receiver operating characteristic (ROC) analysis. The predictive performance was also compared between the Combined model and human readers. Results: Four, five, and five features were selected from NCP, AP, and VP CT images for the development of radiomic models, respectively. The NCP, AP, and VP models exhibited areas under the curve (AUCs) of 0.748 (95% confidence interval [CI], 0.620–0.852), 0.749 (95% CI, 0.620–0.852), and 0.790 (95% CI, 0.665–0.884) in the validation dataset, respectively. The Combined model based on three‐phase CT images outperformed the NCP, AP, and VP models (all p < 0.05), yielding an AUC of 0.882 (95% CI, 0.773–0.951) in the validation dataset. The Combined model displayed noninferior performance compared to two senior radiologists; however, it outperformed two junior radiologists ( p = 0.004 and 0.001, respectively). Conclusion: The Combined model based on radiomic features extracted from three‐phase CT images achieved radiologist‐level performance and could be used as promising noninvasive tool to differentiate PSP from SMPN. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 2(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 2(2021)
- Issue Display:
- Volume 22, Issue 2 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 2
- Issue Sort Value:
- 2021-0022-0002-0000
- Page Start:
- 158
- Page End:
- 164
- Publication Date:
- 2020-12-28
- Subjects:
- CT -- PSP -- radiomic analysis -- SMPN
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13154 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15868.xml