Water Exchange Method Significantly Improves Adenoma Detection Rate: A Multicenter, Randomized Controlled Trial. (April 2017)
- Record Type:
- Journal Article
- Title:
- Water Exchange Method Significantly Improves Adenoma Detection Rate: A Multicenter, Randomized Controlled Trial. (April 2017)
- Main Title:
- Water Exchange Method Significantly Improves Adenoma Detection Rate: A Multicenter, Randomized Controlled Trial
- Authors:
- Jia, Hui
Pan, Yanglin
Guo, Xuegang
Zhao, Lina
Wang, Xiangping
Zhang, Linhui
Dong, Tao
Luo, Hui
Ge, Zhizheng
Liu, Jun
Hao, Jianyu
Yao, Ping
Zhang, Yao
Ren, Hongyu
Zhou, Weizhen
Guo, Yujie
Zhang, Wei
Chen, Xiaolin
Sun, Dayong
Yang, Xiaoqiang
Kang, Xiaoyu
Liu, Na
Liu, Zhiguo
Leung, Felix
Wu, Kaichun
Fan, Daiming - Abstract:
- Abstract : Objectives: Adenoma detection rate (ADR) is a key colonoscopy quality indicator in Western clinical literature. Our low ADR prompted us to assess novel methods to improve performance. Western retrospective reports suggested that water exchange (WE) could increase ADR. However, most of these studies used pain score or intubation rate as the primary outcome. Here we test the hypothesis that WE significantly increases ADR among Chinese colonoscopists and design a prospective randomized controlled trial using ADR as our primary outcome. Methods: This prospective, randomized controlled trial was performed at six centers in China. Screening, surveillance, and diagnostic cases were randomized to be examined by WE or traditional air insufflation (AI) method. The primary outcome was ADR. Results: From April 2014 to July 2015, 3, 303 patients were randomized to WE ( n =1, 653) and AI ( n =1, 650). The baseline characteristics were comparable. Overall ADR was 18.3% (WE) and 13.4% (AI) (relative risk 1.45, 95% confidential interval: 1.20–1.75, P <0.001). ADR in screening patients using AI was 25.8% (male) and 15.7% (female). ADR in screening patients aged >50 years old was 29.4% (WE) and 22.9% (AI) (relative risk 1.09, 95% confidential interval: 1.00–1.19, P =0.040). The increase by WE was reproducibly observed in all indication categories, and significant in screening and diagnostic cases. The limitation imposed by the unblinded investigators was mitigated by comparableAbstract : Objectives: Adenoma detection rate (ADR) is a key colonoscopy quality indicator in Western clinical literature. Our low ADR prompted us to assess novel methods to improve performance. Western retrospective reports suggested that water exchange (WE) could increase ADR. However, most of these studies used pain score or intubation rate as the primary outcome. Here we test the hypothesis that WE significantly increases ADR among Chinese colonoscopists and design a prospective randomized controlled trial using ADR as our primary outcome. Methods: This prospective, randomized controlled trial was performed at six centers in China. Screening, surveillance, and diagnostic cases were randomized to be examined by WE or traditional air insufflation (AI) method. The primary outcome was ADR. Results: From April 2014 to July 2015, 3, 303 patients were randomized to WE ( n =1, 653) and AI ( n =1, 650). The baseline characteristics were comparable. Overall ADR was 18.3% (WE) and 13.4% (AI) (relative risk 1.45, 95% confidential interval: 1.20–1.75, P <0.001). ADR in screening patients using AI was 25.8% (male) and 15.7% (female). ADR in screening patients aged >50 years old was 29.4% (WE) and 22.9% (AI) (relative risk 1.09, 95% confidential interval: 1.00–1.19, P =0.040). The increase by WE was reproducibly observed in all indication categories, and significant in screening and diagnostic cases. The limitation imposed by the unblinded investigators was mitigated by comparable inspection times in cases without polyps, similar adenoma per positive colonoscopy, and reproducible enhancement of ADR and adenoma per colonoscopy by WE across all eight investigators. Conclusions: This prospective study confirms Western retrospective data that WE significantly improves ADR among Chinese colonoscopists. WE may be superior to AI for screening colonoscopy in China. Colonoscopists elsewhere with low ADR might consider evaluating WE for performance improvement. … (more)
- Is Part Of:
- American journal of gastroenterology. Volume 112:Number 4(2017)
- Journal:
- American journal of gastroenterology
- Issue:
- Volume 112:Number 4(2017)
- Issue Display:
- Volume 112, Issue 4 (2017)
- Year:
- 2017
- Volume:
- 112
- Issue:
- 4
- Issue Sort Value:
- 2017-0112-0004-0000
- Page Start:
- Page End:
- Publication Date:
- 2017-04
- Subjects:
- Stomach -- Diseases -- Periodicals
Intestines -- Diseases -- Periodicals
Gastroenterology -- Periodicals
Gastrointestinal Diseases -- Periodicals
Electronic journals
Periodicals
616.33 - Journal URLs:
- http://www.mdconsult.com/public/search?search_type=journal&j_sort=pub_date&j_date_range=1995-current&j_issn=0002-9270 ↗
http://www.amjgastro.com/ ↗
http://www.nature.com/ajg/archive/index.html ↗
http://www.sciencedirect.com/science/journal/00029270 ↗
http://www.nature.com/ ↗
http://www3.interscience.wiley.com/journal/117955841/home ↗
http://firstsearch.oclc.org ↗
http://firstsearch.oclc.org/journal=0002-9270;screen=info;ECOIP ↗ - DOI:
- 10.1038/ajg.2016.501 ↗
- Languages:
- English
- ISSNs:
- 0002-9270
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 0824.650000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15866.xml