Rapid effective dose calculation for raster-scanning 4He ion therapy with the modified microdosimetric kinetic model (mMKM). (January 2021)
- Record Type:
- Journal Article
- Title:
- Rapid effective dose calculation for raster-scanning 4He ion therapy with the modified microdosimetric kinetic model (mMKM). (January 2021)
- Main Title:
- Rapid effective dose calculation for raster-scanning 4He ion therapy with the modified microdosimetric kinetic model (mMKM)
- Authors:
- Kopp, B.
Mein, S.
Tessonnier, T.
Besuglow, J.
Harrabi, S.
Heim, E.
Abdollahi, A.
Haberer, T.
Debus, J.
Mairani, A. - Abstract:
- Highlights: Establish 4 He beam mixed radiation field spectra for the 1st clinical TPS with active beam delivery. Fast GPU-accelerated mMKM – based RBE predications in 4 He ion beam therapy. Sensitivity study towards patient treatment with 4 He ion beam therapy. Abstract: Purpose: To develop and verify effective dose (DRBE ) calculation in 4 He ion beam therapy based on the modified microdosimetric kinetic model (mMKM) and evaluate the bio-sensitivity of mMKM-based plans to clinical parameters using a fast analytical dose engine. Methods: Mixed radiation field particle spectra (MRFS) databases have been generated with Monte-Carlo (MC) simulations for 4 He-ion beams. Relative biological effectiveness (RBE) and DRBE calculation using MRFS were established within a fast analytical engine. Spread-out Bragg-Peaks (SOBPs) in water were optimized for two dose levels and two tissue types with photon linear-quadratic model parameters αph, βph, and (α/β)ph to verify MRFS-derived database implementation against computations with MC-generated mixed-field α and β databases. Bio-sensitivity of the SOBPs was investigated by varying absolute values of βph, while keeping (α/β)ph constant. Additionally, dose, dose-averaged linear energy transfer, and bio-sensitivity were investigated for two patient cases. Results: Using MRFS-derived databases, dose differences ≲2% in the plateau and SOBP are observed compared to computations with MC-generated databases. Bio-sensitivity studies show largerHighlights: Establish 4 He beam mixed radiation field spectra for the 1st clinical TPS with active beam delivery. Fast GPU-accelerated mMKM – based RBE predications in 4 He ion beam therapy. Sensitivity study towards patient treatment with 4 He ion beam therapy. Abstract: Purpose: To develop and verify effective dose (DRBE ) calculation in 4 He ion beam therapy based on the modified microdosimetric kinetic model (mMKM) and evaluate the bio-sensitivity of mMKM-based plans to clinical parameters using a fast analytical dose engine. Methods: Mixed radiation field particle spectra (MRFS) databases have been generated with Monte-Carlo (MC) simulations for 4 He-ion beams. Relative biological effectiveness (RBE) and DRBE calculation using MRFS were established within a fast analytical engine. Spread-out Bragg-Peaks (SOBPs) in water were optimized for two dose levels and two tissue types with photon linear-quadratic model parameters αph, βph, and (α/β)ph to verify MRFS-derived database implementation against computations with MC-generated mixed-field α and β databases. Bio-sensitivity of the SOBPs was investigated by varying absolute values of βph, while keeping (α/β)ph constant. Additionally, dose, dose-averaged linear energy transfer, and bio-sensitivity were investigated for two patient cases. Results: Using MRFS-derived databases, dose differences ≲2% in the plateau and SOBP are observed compared to computations with MC-generated databases. Bio-sensitivity studies show larger deviations when altering the absolute βph value, with maximum D50% changes of ~5%, with similar results for patient cases. Bio-sensitivity analysis indicates a greater impact on DRBE varying (α/β)ph than βph in mMKM. Conclusions: The MRSF approach yielded negligible differences in the target and small differences in the plateau compared to MC-generated databases. The presented analyses provide guidance for proper implementation of RBE-weighted 4 He ion dose prescription and planning with mMKM. The MRFS-DRBE calculation approach using mMKM will be implemented in a clinical treatment planning system. … (more)
- Is Part Of:
- Physica medica. Volume 81(2021)
- Journal:
- Physica medica
- Issue:
- Volume 81(2021)
- Issue Display:
- Volume 81, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 81
- Issue:
- 2021
- Issue Sort Value:
- 2021-0081-2021-0000
- Page Start:
- 273
- Page End:
- 284
- Publication Date:
- 2021-01
- Subjects:
- Helium ion therapy -- Biological model -- FRoG/PRECISE -- Heidelberg Ion-Beam Therapy Center
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.11.028 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15857.xml