Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model. (January 2021)
- Record Type:
- Journal Article
- Title:
- Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model. (January 2021)
- Main Title:
- Near real-time magnetic particle imaging for visual assessment of vascular stenosis in a phantom model
- Authors:
- Dietrich, Philipp
Vogel, Patrick
Kampf, Thomas
Rückert, Martin A.
Behr, Volker C.
Bley, Thorsten A.
Herz, Stefan - Abstract:
- Abstract: Purpose: This study aimed to investigate the potential of magnetic particle imaging (MPI) to quantify artificial stenoses in vessel phantoms in near real-time. Methods: Custom-made stenosis phantoms with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%; length 40 mm, inner diameter 8 mm, Polyoxymethylene) were filled with diluted Ferucarbotran (superparamagnetic iron-oxide nanoparticle (SPION) tracer agent, 500 mmol (Fe)/l). A traveling wave MPI scanner (spatial resolution ~ 2 mm, gradient strength ~ 1.5 T/m, field of view: 65 mm length and 29 mm diameter, frequencies f 1 = 1050 Hz and f 2 = 12150 Hz) was used to acquire images of the phantoms (200 ms total acquisition time per image, 10 averages). Standardized grey scaling was used for comparability. All measured stenoses ( n = 80) were graded manually using a dedicated software tool. Results: MPI allowed for accurate visualization of stenoses at a frame rate of 5 frames per second. Less severe stenoses were detected more precisely than higher-grade stenoses and came with smaller standard deviations. In particular, the 0%, 25%, 50%, 75%, and 100% stenosis phantom were measured as 3.7 ± 2.7% (mean ± standard deviation), 18.6 ± 1.8%, 52.8 ± 3.7%, 77.8 ± 14.8% and 100 ± 0%. Geometrical distortions occurred around the center of the high-grade stenosis and led to higher standard deviations compared to lower grade stenoses. In the frame of this study the MPI signal depended linearly on the SPIONAbstract: Purpose: This study aimed to investigate the potential of magnetic particle imaging (MPI) to quantify artificial stenoses in vessel phantoms in near real-time. Methods: Custom-made stenosis phantoms with different degrees of stenosis (0%, 25%, 50%, 75%, and 100%; length 40 mm, inner diameter 8 mm, Polyoxymethylene) were filled with diluted Ferucarbotran (superparamagnetic iron-oxide nanoparticle (SPION) tracer agent, 500 mmol (Fe)/l). A traveling wave MPI scanner (spatial resolution ~ 2 mm, gradient strength ~ 1.5 T/m, field of view: 65 mm length and 29 mm diameter, frequencies f 1 = 1050 Hz and f 2 = 12150 Hz) was used to acquire images of the phantoms (200 ms total acquisition time per image, 10 averages). Standardized grey scaling was used for comparability. All measured stenoses ( n = 80) were graded manually using a dedicated software tool. Results: MPI allowed for accurate visualization of stenoses at a frame rate of 5 frames per second. Less severe stenoses were detected more precisely than higher-grade stenoses and came with smaller standard deviations. In particular, the 0%, 25%, 50%, 75%, and 100% stenosis phantom were measured as 3.7 ± 2.7% (mean ± standard deviation), 18.6 ± 1.8%, 52.8 ± 3.7%, 77.8 ± 14.8% and 100 ± 0%. Geometrical distortions occurred around the center of the high-grade stenosis and led to higher standard deviations compared to lower grade stenoses. In the frame of this study the MPI signal depended linearly on the SPION concentration down to 0.05 mmol (Fe)/l. Conclusion: Near real-time MPI accurately visualized and quantified different stenosis grades in vascular phantoms. … (more)
- Is Part Of:
- Physica medica. Volume 81(2021)
- Journal:
- Physica medica
- Issue:
- Volume 81(2021)
- Issue Display:
- Volume 81, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 81
- Issue:
- 2021
- Issue Sort Value:
- 2021-0081-2021-0000
- Page Start:
- 210
- Page End:
- 214
- Publication Date:
- 2021-01
- Subjects:
- Magnetic particle imaging -- MPI -- Stenosis quantification -- Vascular stenosis
Medical physics -- Periodicals
Biophysics -- Periodicals
Biophysics -- Periodicals
Imagerie médicale -- Périodiques
Radiothérapie -- Périodiques
Rayons X -- Sécurité -- Mesures -- Périodiques
Physique -- Périodiques
Médecine -- Périodiques
610.153 - Journal URLs:
- http://www.sciencedirect.com/science/journal/11201797 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/11201797 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/11201797 ↗
http://www.elsevier.com/journals ↗
http://www.physicamedica.com ↗ - DOI:
- 10.1016/j.ejmp.2020.12.020 ↗
- Languages:
- English
- ISSNs:
- 1120-1797
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 6475.070000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15857.xml