A link between bilirubin levels and atrial fibrillation recurrence after catheter ablation. Issue 3 (March 2019)
- Record Type:
- Journal Article
- Title:
- A link between bilirubin levels and atrial fibrillation recurrence after catheter ablation. Issue 3 (March 2019)
- Main Title:
- A link between bilirubin levels and atrial fibrillation recurrence after catheter ablation
- Authors:
- Chen, Su-Chan
Chung, Fa-Po
Chao, Tze-Fan
Hu, Yu-Feng
Lin, Yenn-Jiang
Chang, Shih-Lin
Lo, Li-Wei
Tuan, Ta-Chuan
Te, Abigail Louise D.
Yamada, Shinya
Prabhu, Atul
Chang, Ting-Yung
Lin, Chin-Yu
Chen, Shih-Ann - Abstract:
- Abstract : Background: Bilirubin is associated with different cardiovascular diseases. The relationship between bilirubin and atrial fibrillation (AF) remains unclear. The aim of this study is to determine the association between bilirubin and AF recurrence after catheter ablation. Methods: A total of 212 patients who received AF ablation were retrospectively studied. The total bilirubin level, clinical characteristics, and echocardiographic findings were analyzed to predict the outcome of AF ablations. Results: During a mean follow-up period of 12.2 ± 5.8 months, 61 (28.8%) patients had AF recurrence after catheter ablation. The patients with AF recurrence had a larger left atrial (LA) diameter (39.8 ± 6.3 versus 36.7 ± 5.8 mm; p = 0.001) and higher total bilirubin levels (0.82 ± 0.37 versus 0.63 ± 0.29 mg/dL; p < 0.001) than those without recurrence. The patients with recurrence had higher direct and indirect bilirubin levels than patients without recurrence. The total bilirubin level remained an independent predictor of AF recurrence after multivariate analysis (odds ratio, 4.95; 95% CI, 1.65-14.83; p = 0.004). We identified a cut point of the total bilirubin level for predicting AF recurrence by receiver operator characteristic curve (cut point, 0.7 mg/dL; area under the curve, 0.65; p < 0.001). The total bilirubin levels were positively correlated with the neutrophil counts. However, there were no associations among the total bilirubin level, left atrial (LA) diameter,Abstract : Background: Bilirubin is associated with different cardiovascular diseases. The relationship between bilirubin and atrial fibrillation (AF) remains unclear. The aim of this study is to determine the association between bilirubin and AF recurrence after catheter ablation. Methods: A total of 212 patients who received AF ablation were retrospectively studied. The total bilirubin level, clinical characteristics, and echocardiographic findings were analyzed to predict the outcome of AF ablations. Results: During a mean follow-up period of 12.2 ± 5.8 months, 61 (28.8%) patients had AF recurrence after catheter ablation. The patients with AF recurrence had a larger left atrial (LA) diameter (39.8 ± 6.3 versus 36.7 ± 5.8 mm; p = 0.001) and higher total bilirubin levels (0.82 ± 0.37 versus 0.63 ± 0.29 mg/dL; p < 0.001) than those without recurrence. The patients with recurrence had higher direct and indirect bilirubin levels than patients without recurrence. The total bilirubin level remained an independent predictor of AF recurrence after multivariate analysis (odds ratio, 4.95; 95% CI, 1.65-14.83; p = 0.004). We identified a cut point of the total bilirubin level for predicting AF recurrence by receiver operator characteristic curve (cut point, 0.7 mg/dL; area under the curve, 0.65; p < 0.001). The total bilirubin levels were positively correlated with the neutrophil counts. However, there were no associations among the total bilirubin level, left atrial (LA) diameter, and voltage. Conclusion: Higher serum bilirubin levels were associated with AF recurrence in paroxysmal AF patients following catheter ablation. … (more)
- Is Part Of:
- Journal of the Chinese Medical Association. Volume 82:Issue 3(2019)
- Journal:
- Journal of the Chinese Medical Association
- Issue:
- Volume 82:Issue 3(2019)
- Issue Display:
- Volume 82, Issue 3 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 3
- Issue Sort Value:
- 2019-0082-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-03
- Subjects:
- Atrial fibrillation -- Bilirubin -- Catheter ablation -- Recurrence
Medicine -- Periodicals
610.5 - Journal URLs:
- https://journals.lww.com/jcma/pages/default.aspx ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1097/JCMA.0000000000000026 ↗
- Languages:
- English
- ISSNs:
- 1726-4901
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4729.330050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15834.xml