Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer. Issue 1 (January 2020)
- Main Title:
- Comparison of formula accuracy for intraocular lens power calculation based on measurements by a swept-source optical coherence tomography optical biometer
- Authors:
- Savini, Giacomo
Hoffer, Kenneth J.
Balducci, Nicole
Barboni, Piero
Schiano-Lomoriello, Domenico - Abstract:
- Abstract : Purpose: To analyze the results of intraocular lens (IOL) power calculation using measurements by a swept-source optical coherence tomography (SS-OCT) optical biometer. Setting: IRCCS G.B. Bietti Foundation, Rome, Italy. Design: Evaluation of a diagnostic test instrument. Methods: Preoperative measurements by the OA-2000 (Tomey Inc.) were taken in a consecutive series of patients undergoing cataract surgery with one IOL model (AcrySof SN60WF; Alcon Laboratories, Inc.). Measurements were entered into the following formulas: Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Hoffer Q, Holladay 1, Holladay 2, Holladay 2 with axial length adjustment, Kane, Olsen, Panacea, SRK/T, T2, and VRF. When refraction was measured at 1 month postoperatively, the mean arithmetic prediction error, the median absolute error (MedAE), and the percentage of eyes with a error of ±0.50 D or less were calculated after constant optimization. Results: We enrolled 150 eyes. All formulas yielded excellent outcomes. The MedAE ranged between 0.200 D and 0.259 D, with a statistically significant difference among formulas ( P = .0004). The lowest MedAE values were obtained with the Barrett, EVO, Kane, Olsenstandalone, Radial Basis Function (RBF), and T2 formulas. The percentage of eyes with a prediction error of ±0.50 D or less ranged between 80.00% and 90.67%, with a statistically significant difference ( P < .0001). The Barrett, EVO, Holladay 2 with axial length adjustment,Abstract : Purpose: To analyze the results of intraocular lens (IOL) power calculation using measurements by a swept-source optical coherence tomography (SS-OCT) optical biometer. Setting: IRCCS G.B. Bietti Foundation, Rome, Italy. Design: Evaluation of a diagnostic test instrument. Methods: Preoperative measurements by the OA-2000 (Tomey Inc.) were taken in a consecutive series of patients undergoing cataract surgery with one IOL model (AcrySof SN60WF; Alcon Laboratories, Inc.). Measurements were entered into the following formulas: Barrett Universal II, Emmetropia Verifying Optical (EVO), Haigis, Hoffer Q, Holladay 1, Holladay 2, Holladay 2 with axial length adjustment, Kane, Olsen, Panacea, SRK/T, T2, and VRF. When refraction was measured at 1 month postoperatively, the mean arithmetic prediction error, the median absolute error (MedAE), and the percentage of eyes with a error of ±0.50 D or less were calculated after constant optimization. Results: We enrolled 150 eyes. All formulas yielded excellent outcomes. The MedAE ranged between 0.200 D and 0.259 D, with a statistically significant difference among formulas ( P = .0004). The lowest MedAE values were obtained with the Barrett, EVO, Kane, Olsenstandalone, Radial Basis Function (RBF), and T2 formulas. The percentage of eyes with a prediction error of ±0.50 D or less ranged between 80.00% and 90.67%, with a statistically significant difference ( P < .0001). The Barrett, EVO, Holladay 2 with axial length adjustment, Kane, RBF, and T2 achieved the highest percentages (≥88%). Conclusions: Measurements provided by the SS-OCT optical biometer enable accurate IOL power calculation because all formulas yielded a prediction error within 0.50 D in at least 80% of eyes. Abstract : Older and newer formulas provide accurate IOL power calculations when using SS-OCT optical biometer measurements. More than 80% of eyes are expected to have a prediction error within 0.50 D. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 46:Issue 1(2020)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 46:Issue 1(2020)
- Issue Display:
- Volume 46, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2020-0046-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2019.08.044 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15826.xml