Anterior chamber lens sizing: Comparison of white-to-white and scleral spur–to–scleral spur methods. Issue 1 (January 2020)
- Record Type:
- Journal Article
- Title:
- Anterior chamber lens sizing: Comparison of white-to-white and scleral spur–to–scleral spur methods. Issue 1 (January 2020)
- Main Title:
- Anterior chamber lens sizing
- Authors:
- Bruner, Cameron
Skanchy, David F.
Wooten, John P.
Chuang, Alice Z.
Kim, Gene - Abstract:
- Abstract : Purpose: To determine the most accurate method of estimating scleral–spur–to–scleral–spur (STS) distance for ophthalmologists without access to an anterior chamber optical coherence tomography (AS-OCT) instrument when selecting an anterior chamber intraocular lens (AC IOL). Setting: Robert Cizik Eye Clinic, Houston, TX. Design: Prospective cohort study. Methods: The eyes of 65 participants aged 18 years or older were imaged by the Lenstar LS 900 optical biometer and CASIA SS-1000 swept-source Fourier-domain AS-OCT. Eyes were excluded if the anterior segment anatomy was significantly altered and the angle could not be visualized. When both eyes were eligible, 1 eye was randomly selected. The white-to-white (WTW) distance, STS distance, and axial length were recorded and compared. The difference between STS and horizontal WTW was calculated for each meridian. The mean (±SD) differences, 95% limits of agreement, and Bland–Altman agreement were computed for each pair of STS and WTW measurements. Results: The study comprised 65 eyes of 65 participants. In nearly every case, WTW + 0.5 and WTW + 1 overestimated STS. The horizontal WTW without adjustment was the best predictor of STS. The WTW best corresponded to the vertical STS meridian (6 to 12 o'clock) and not the horizontal meridian (3 to 9 o'clock), along which AC IOLs are traditionally placed. Conclusions: The horizontal WTW method without an adjustment factor most accurately estimated STS distance and should beAbstract : Purpose: To determine the most accurate method of estimating scleral–spur–to–scleral–spur (STS) distance for ophthalmologists without access to an anterior chamber optical coherence tomography (AS-OCT) instrument when selecting an anterior chamber intraocular lens (AC IOL). Setting: Robert Cizik Eye Clinic, Houston, TX. Design: Prospective cohort study. Methods: The eyes of 65 participants aged 18 years or older were imaged by the Lenstar LS 900 optical biometer and CASIA SS-1000 swept-source Fourier-domain AS-OCT. Eyes were excluded if the anterior segment anatomy was significantly altered and the angle could not be visualized. When both eyes were eligible, 1 eye was randomly selected. The white-to-white (WTW) distance, STS distance, and axial length were recorded and compared. The difference between STS and horizontal WTW was calculated for each meridian. The mean (±SD) differences, 95% limits of agreement, and Bland–Altman agreement were computed for each pair of STS and WTW measurements. Results: The study comprised 65 eyes of 65 participants. In nearly every case, WTW + 0.5 and WTW + 1 overestimated STS. The horizontal WTW without adjustment was the best predictor of STS. The WTW best corresponded to the vertical STS meridian (6 to 12 o'clock) and not the horizontal meridian (3 to 9 o'clock), along which AC IOLs are traditionally placed. Conclusions: The horizontal WTW method without an adjustment factor most accurately estimated STS distance and should be used to select AC IOL size when AS-OCT is not available. If AS-OCT is available, it should be used instead. In addition, AC IOLs should be placed in a vertical orientation rather than the traditional horizontal orientation to minimize sizing errors. Abstract : Horizontal white-to-white measurement without adjustment most accurately represents anterior chamber sizing. Vertical meridian lens orientation may minimize complications when placing an anterior chamber intraocular lens. … (more)
- Is Part Of:
- Journal of cataract and refractive surgery. Volume 46:Issue 1(2020)
- Journal:
- Journal of cataract and refractive surgery
- Issue:
- Volume 46:Issue 1(2020)
- Issue Display:
- Volume 46, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2020-0046-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- 617.7
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1016/j.jcrs.2019.08.043 ↗
- Languages:
- English
- ISSNs:
- 0886-3350
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4954.900000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15826.xml