Agreement of post-LASIK corneal power and corneal thickness measurements by pentacam and GALILEI corneal tomography systems. Issue 1 (January 2019)
- Record Type:
- Journal Article
- Title:
- Agreement of post-LASIK corneal power and corneal thickness measurements by pentacam and GALILEI corneal tomography systems. Issue 1 (January 2019)
- Main Title:
- Agreement of post-LASIK corneal power and corneal thickness measurements by pentacam and GALILEI corneal tomography systems
- Authors:
- Hsieh, Yun-Hsiu
Weng, Tzu-Heng
Chou, Yu-Ching
Wu, Kuan-Liang
Liang, Chang-Min
Tai, Ming-Cheng - Abstract:
- Abstract : Background: Post-LASIK corneal conditions cannot be accurately measured by traditional optometric approaches. Therefore, we aimed to analyze the agreement of two rotating Scheimpflug cameras in corneal assessment. Methods: Fifty otherwise healthy volunteers who had undergone LASIK were recruited in this study. The values of mean and central total corneal power (TCP), including TCP1, TCP2, and TCP-IOL, were measured by GALILEI Scheimpflug camera. The values of total corneal refractive power (TCRP) readings at both 2 mm ring and 3 and 4 mm zones were detected by Pentacam Scheimpflug camera. Central corneal thickness (CCT) and thinnest corneal thickness (TCT) were quantified by GALILEI and Pentacam respectively. Paired t -tests and Bland–Altman analyses were used to evaluate statistical differences between measurement results obtained by GALILEI and by Pentacam. Results: Among these 50 subjects, the mean and central TCP1 values (37.31 ± 2.61 and 37.27 ± 2.64) derived from GALILEI measurements were consistent with the TCRP values (37.08 ± 2.76, 37.11 ± 2.74, and 37.19 ± 2.68; p > 0.05) determined by Pentacam at the 2 mm ring apex, 3 mm zone apex, and 4 mm zone apex. There were no statistically significant differences in central corneal thickness (CCT) values measured by the two cameras (463.64 ± 55.67 μm for GALILEI and 470.69 ± 44.04 μm for Pentacam, respectively; p > 0.05). However, the limits of agreement were wide when comparing mean TCP1 (−1.4 to 1.8 D, −1.4 toAbstract : Background: Post-LASIK corneal conditions cannot be accurately measured by traditional optometric approaches. Therefore, we aimed to analyze the agreement of two rotating Scheimpflug cameras in corneal assessment. Methods: Fifty otherwise healthy volunteers who had undergone LASIK were recruited in this study. The values of mean and central total corneal power (TCP), including TCP1, TCP2, and TCP-IOL, were measured by GALILEI Scheimpflug camera. The values of total corneal refractive power (TCRP) readings at both 2 mm ring and 3 and 4 mm zones were detected by Pentacam Scheimpflug camera. Central corneal thickness (CCT) and thinnest corneal thickness (TCT) were quantified by GALILEI and Pentacam respectively. Paired t -tests and Bland–Altman analyses were used to evaluate statistical differences between measurement results obtained by GALILEI and by Pentacam. Results: Among these 50 subjects, the mean and central TCP1 values (37.31 ± 2.61 and 37.27 ± 2.64) derived from GALILEI measurements were consistent with the TCRP values (37.08 ± 2.76, 37.11 ± 2.74, and 37.19 ± 2.68; p > 0.05) determined by Pentacam at the 2 mm ring apex, 3 mm zone apex, and 4 mm zone apex. There were no statistically significant differences in central corneal thickness (CCT) values measured by the two cameras (463.64 ± 55.67 μm for GALILEI and 470.69 ± 44.04 μm for Pentacam, respectively; p > 0.05). However, the limits of agreement were wide when comparing mean TCP1 (−1.4 to 1.8 D, −1.4 to 1.8 D, and −1.3 to 1.6 D), central TCP1 (−1.2 to 1.6 D, −1.2 to 1.6 D, and −1.2 to 1.4 D) and CCT (−77.2–63.0 μm). Conclusion: Corneal power and corneal thickness are disparate post-LASIK evaluation parameters when comparing the utility of GALILEI with that of Pentacam. … (more)
- Is Part Of:
- Journal of the Chinese Medical Association. Volume 82:Issue 1(2019)
- Journal:
- Journal of the Chinese Medical Association
- Issue:
- Volume 82:Issue 1(2019)
- Issue Display:
- Volume 82, Issue 1 (2019)
- Year:
- 2019
- Volume:
- 82
- Issue:
- 1
- Issue Sort Value:
- 2019-0082-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2019-01
- Subjects:
- Corneal power -- Corneal thickness -- GALILEI -- Laser-assisted in situ keratomileusis (LASIK) -- Pentacam
Medicine -- Periodicals
610.5 - Journal URLs:
- https://journals.lww.com/jcma/pages/default.aspx ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.jcma.2018.07.005 ↗
- Languages:
- English
- ISSNs:
- 1726-4901
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4729.330050
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15829.xml