A Carotid Doppler Patch Accurately Tracks Stroke Volume Changes During a Preload-Modifying Maneuver in Healthy Volunteers. (January 2020)
- Record Type:
- Journal Article
- Title:
- A Carotid Doppler Patch Accurately Tracks Stroke Volume Changes During a Preload-Modifying Maneuver in Healthy Volunteers. (January 2020)
- Main Title:
- A Carotid Doppler Patch Accurately Tracks Stroke Volume Changes During a Preload-Modifying Maneuver in Healthy Volunteers
- Authors:
- Kenny, Jon-Émile S.
Barjaktarevic, Igor
Eibl, Andrew M.
Parrotta, Matthew
Long, Bradley F.
Eibl, Joseph K.
Michard, Frederic - Abstract:
- Abstract : Objectives: Detecting instantaneous stroke volume change in response to altered cardiac preload is the physiologic foundation for determining preload responsiveness. Design: Proof-of-concept physiology study. Setting: Research simulation laboratory. Subjects: Twelve healthy volunteers. Interventions: A wireless continuous wave Doppler ultrasound patch was used to measure carotid velocity time integral and carotid corrected flow time during a squat maneuver. The Doppler patch measurements were compared with simultaneous stroke volume measurements obtained from a noninvasive cardiac output monitor. Measurements and Main Results: From stand to squat, stroke volume increased by 24% while carotid velocity time integral and carotid corrected flow time increased by 32% and 9%, respectively. From squat to stand, stroke volume decreased by 13%, while carotid velocity time integral and carotid corrected flow time decreased by 24% and 10%, respectively. Both changes in carotid velocity time integral and corrected flow time were closely correlated with changes in stroke volume ( r 2 = 0.81 and 0.62, respectively). The four-quadrant plot found a 100% concordance rate between changes in stroke volume and both changes in carotid velocity time integral and changes in corrected flow time. A change in carotid velocity time integral greater than 15% predicted a change in stroke volume greater than 10% with a sensitivity of 95% and a specificity of 92%. A change in carotid correctedAbstract : Objectives: Detecting instantaneous stroke volume change in response to altered cardiac preload is the physiologic foundation for determining preload responsiveness. Design: Proof-of-concept physiology study. Setting: Research simulation laboratory. Subjects: Twelve healthy volunteers. Interventions: A wireless continuous wave Doppler ultrasound patch was used to measure carotid velocity time integral and carotid corrected flow time during a squat maneuver. The Doppler patch measurements were compared with simultaneous stroke volume measurements obtained from a noninvasive cardiac output monitor. Measurements and Main Results: From stand to squat, stroke volume increased by 24% while carotid velocity time integral and carotid corrected flow time increased by 32% and 9%, respectively. From squat to stand, stroke volume decreased by 13%, while carotid velocity time integral and carotid corrected flow time decreased by 24% and 10%, respectively. Both changes in carotid velocity time integral and corrected flow time were closely correlated with changes in stroke volume ( r 2 = 0.81 and 0.62, respectively). The four-quadrant plot found a 100% concordance rate between changes in stroke volume and both changes in carotid velocity time integral and changes in corrected flow time. A change in carotid velocity time integral greater than 15% predicted a change in stroke volume greater than 10% with a sensitivity of 95% and a specificity of 92%. A change in carotid corrected flow time greater than 4% predicted a change in stroke volume greater than 10% with a sensitivity of 90% and a specificity of 92%. Conclusions: In healthy volunteers, both carotid velocity time integral and carotid corrected flow time measured by a wireless Doppler patch were useful to track changes in stroke volume induced by a preload-modifying maneuver with high sensitivity and specificity. … (more)
- Is Part Of:
- Critical care explorations. Volume 2:Number 1(2020)
- Journal:
- Critical care explorations
- Issue:
- Volume 2:Number 1(2020)
- Issue Display:
- Volume 2, Issue 1 (2020)
- Year:
- 2020
- Volume:
- 2
- Issue:
- 1
- Issue Sort Value:
- 2020-0002-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-01
- Subjects:
- carotid ultrasound -- corrected flow time -- fluid responsiveness -- stroke volume -- velocity time interval
- Journal URLs:
- http://journals.lww.com/pages/default.aspx ↗
- DOI:
- 10.1097/CCE.0000000000000072 ↗
- Languages:
- English
- ISSNs:
- 2639-8028
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15832.xml