Characterizing Glycemic Control and Sleep in Adults with Long-Standing Type 1 Diabetes and Hypoglycemia Unawareness Initiating Hybrid Closed Loop Insulin Delivery. (13th February 2021)
- Record Type:
- Journal Article
- Title:
- Characterizing Glycemic Control and Sleep in Adults with Long-Standing Type 1 Diabetes and Hypoglycemia Unawareness Initiating Hybrid Closed Loop Insulin Delivery. (13th February 2021)
- Main Title:
- Characterizing Glycemic Control and Sleep in Adults with Long-Standing Type 1 Diabetes and Hypoglycemia Unawareness Initiating Hybrid Closed Loop Insulin Delivery
- Authors:
- Malone, Susan Kohl
Peleckis, Amy J.
Grunin, Laura
Yu, Gary
Jang, Sooyong
Weimer, James
Lee, Insup
Rickels, Michael R.
Goel, Namni - Other Names:
- Scaramuzza Andrea Academic Editor.
- Abstract:
- Abstract : Nocturnal hypoglycemia is life threatening for individuals with type 1 diabetes (T1D) due to loss of hypoglycemia symptom recognition (hypoglycemia unawareness) and impaired glucose counter regulation. These individuals also show disturbed sleep, which may result from glycemic dysregulation. Whether use of a hybrid closed loop (HCL) insulin delivery system with integrated continuous glucose monitoring (CGM) designed for improving glycemic control, relates to better sleep across time in this population remains unknown. The purpose of this study was to describe long-term changes in glycemic control and objective sleep after initiating hybrid closed loop (HCL) insulin delivery in adults with type 1 diabetes and hypoglycemia unawareness. To accomplish this, six adults (median age = 58 y ) participated in an 18-month ongoing trial assessing HCL effectiveness. Glycemic control and sleep were measured using continuous glucose monitoring and wrist accelerometers every 3 months. Paired sample t -tests and Cohen's d effect sizes modeled glycemic and sleep changes and the magnitude of these changes from baseline to 9 months. Reduced hypoglycemia (d = 0.47 ‐ 0.79 ), reduced basal insulin requirements (d = 0.48 ), and a smaller glucose coefficient of variation (d = 0.47 ) occurred with medium-large effect sizes from baseline to 9 months. Hypoglycemia awareness improved from baseline to 6 months with medium-large effect sizes (Clarke score (d = 0.60 ), lability index (d =Abstract : Nocturnal hypoglycemia is life threatening for individuals with type 1 diabetes (T1D) due to loss of hypoglycemia symptom recognition (hypoglycemia unawareness) and impaired glucose counter regulation. These individuals also show disturbed sleep, which may result from glycemic dysregulation. Whether use of a hybrid closed loop (HCL) insulin delivery system with integrated continuous glucose monitoring (CGM) designed for improving glycemic control, relates to better sleep across time in this population remains unknown. The purpose of this study was to describe long-term changes in glycemic control and objective sleep after initiating hybrid closed loop (HCL) insulin delivery in adults with type 1 diabetes and hypoglycemia unawareness. To accomplish this, six adults (median age = 58 y ) participated in an 18-month ongoing trial assessing HCL effectiveness. Glycemic control and sleep were measured using continuous glucose monitoring and wrist accelerometers every 3 months. Paired sample t -tests and Cohen's d effect sizes modeled glycemic and sleep changes and the magnitude of these changes from baseline to 9 months. Reduced hypoglycemia (d = 0.47 ‐ 0.79 ), reduced basal insulin requirements (d = 0.48 ), and a smaller glucose coefficient of variation (d = 0.47 ) occurred with medium-large effect sizes from baseline to 9 months. Hypoglycemia awareness improved from baseline to 6 months with medium-large effect sizes (Clarke score (d = 0.60 ), lability index (d = 0.50 ), HYPO score (d = 1.06 )). Shorter sleep onset latency (d = 1.53 ; p < 0.01 ), shorter sleep duration (d = 0.79 ), fewer total activity counts (d = 1.32 ), shorter average awakening length (d = 0.46 ), and delays in sleep onset (d = 1.06 ) and sleep midpoint (d = 0.72 ) occurred with medium-large effect sizes from baseline to 9 months. HCL led to clinically significant reductions in hypoglycemia and improved hypoglycemia awareness. Sleep showed a delayed onset, reduced awakening length and onset latency, and maintenance of high sleep efficiency after initiating HCL. Our findings add to the limited evidence on the relationships between diabetes therapeutic technologies and sleep health. This trial is registered with ClinicalTrials.gov (NCT03215914 ). … (more)
- Is Part Of:
- Journal of diabetes research. Volume 2021(2021)
- Journal:
- Journal of diabetes research
- Issue:
- Volume 2021(2021)
- Issue Display:
- Volume 2021, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 2021
- Issue:
- 2021
- Issue Sort Value:
- 2021-2021-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-02-13
- Subjects:
- Diabetes -- Periodicals
Diabetes -- Pathophysiology -- Periodicals
Diabetes -- Prevention -- Periodicals
Diabetes -- Etiology -- Periodicals
Diabetes -- Epidemiology -- Periodicals
Diabetes -- Pathogenesis -- Periodicals
616.462005 - Journal URLs:
- https://www.hindawi.com/journals/jdr/ ↗
- DOI:
- 10.1155/2021/6611064 ↗
- Languages:
- English
- ISSNs:
- 2314-6745
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library HMNTS - ELD Digital store
- Ingest File:
- 15825.xml