Miniaturized electrocoagulation approach for removal of polymeric pigments and selective analysis of non- and mono-hydroxylated phenolic acids in wine with HPLC-UV. Issue 11 (2nd February 2021)
- Record Type:
- Journal Article
- Title:
- Miniaturized electrocoagulation approach for removal of polymeric pigments and selective analysis of non- and mono-hydroxylated phenolic acids in wine with HPLC-UV. Issue 11 (2nd February 2021)
- Main Title:
- Miniaturized electrocoagulation approach for removal of polymeric pigments and selective analysis of non- and mono-hydroxylated phenolic acids in wine with HPLC-UV
- Authors:
- Chindaphan, Kanokporn
Thaveesangsakulthai, Isaya
Naranaruemol, Suchapa
Nhujak, Thumnoon
Panchompoo, Janjira
Chailapakul, Orawon
Kulsing, Chadin - Abstract:
- Abstract : Electrocoagulation (EC) approach was developed to allow fast sample clean-up step prior to selective analysis of non- and mono-hydroxylated phenolic acids in red wine samples with high performance liquid chromatography hyphenated with UV detection (HPLC-UV). Abstract : Electrocoagulation (EC) approach was developed to allow fast sample cleanup step prior to selective analysis of non- and mono-hydroxylated phenolic acids in red wine samples with high performance liquid chromatography hyphenated with UV detection (HPLC-UV). EC system with the wine in KCl(aq) electrolyte (1.5 mol L −1 ) was employed removing the polymeric pigments with good recovery of 39 peaks from 64 peaks. The mechanisms mainly involve enrichment induced aggregation and reduction of the pigments at the cathode and the adsorption onto the EC sludge. The EC was further miniaturized employing two intercalated stainless steel spring electrodes at 9.0 V which allowed removal of >99% interference peak area from the pigments within 5 s. The recoveries of the target phenolic acids ( p -hydroxybenzoic acid, vanillic acid, syringic acid and ferulic acid) were within the range of 86–102%. The repeated analysis of these standards revealed <2 and ≤10% RSD of the intra-day and inter-day precisions, respectively. The linearities of their calibration curves were observed with R 2 > 0.99. Their method detection limits were within the range of 0.02–0.20 mg L −1 .
- Is Part Of:
- RSC advances. Volume 11:Issue 11(2021)
- Journal:
- RSC advances
- Issue:
- Volume 11:Issue 11(2021)
- Issue Display:
- Volume 11, Issue 11 (2021)
- Year:
- 2021
- Volume:
- 11
- Issue:
- 11
- Issue Sort Value:
- 2021-0011-0011-0000
- Page Start:
- 5885
- Page End:
- 5893
- Publication Date:
- 2021-02-02
- Subjects:
- Chemistry -- Periodicals
540.5 - Journal URLs:
- http://pubs.rsc.org/en/Journals/JournalIssues/RA ↗
http://www.rsc.org/ ↗ - DOI:
- 10.1039/d0ra09089a ↗
- Languages:
- English
- ISSNs:
- 2046-2069
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8036.750300
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15849.xml