Poststudy Point-of-Care Oral Fluid Testing in Human Immunodeficiency Virus-1 Vaccinees. (15th December 2020)
- Record Type:
- Journal Article
- Title:
- Poststudy Point-of-Care Oral Fluid Testing in Human Immunodeficiency Virus-1 Vaccinees. (15th December 2020)
- Main Title:
- Poststudy Point-of-Care Oral Fluid Testing in Human Immunodeficiency Virus-1 Vaccinees
- Authors:
- Oganezova, Karina
Fontana-Martinez, Elvin J
Gothing, Jon A
Pandit, Alisha
Kwara, Esther
Yanosick, Katherine
Dragavon, Joan
Goecker, Erin A
Maenza, Janine
Espy, Nicole
Tomaka, Frank
Lavreys, Ludo
Allen, Mary
D'Souza, Patricia
Hural, John
Coombs, Robert W
Dolin, Raphael
Seaman, Michael S
Walsh, Stephen R
Baden, Lindsey R - Abstract:
- Abstract: Background: Experimental human immunodeficiency virus (HIV)-1 vaccines frequently elicit antibodies against HIV-1 that may react with commonly used HIV diagnostic tests, a phenomenon known as vaccine-induced seropositivity/seroreactivity (VISP/VISR). We sought to determine, under clinic conditions, whether a patient-controlled HIV test, OraQuick ADVANCE Rapid HIV-1/2 Antibody Test, detected HIV-1 vaccine-induced antibodies. Methods: Plasma assessment of HIV-1 cross-reactivity was examined in end-of-study samples from 57 healthy, HIV-uninfected participants who received a candidate vaccine that has entered Phase 2B and 3 testing. We also screened 120 healthy, HIV-uninfected, unblinded HIV-1 vaccine participants with VISP/VISR for an assessment using saliva. These participants came from 21 different parent vaccine protocols representing 17 different vaccine regimens, all of which contained an HIV-1 envelope immunogen. OraQuick ADVANCE was compared with results from concurrent blood samples using a series of commercial HIV screening immunoassays. Results: Fifty-seven unique participant plasma samples were assayed in vitro, and only 1 (1.8%) was reactive by OraQuick ADVANCE. None of the 120 clinic participants (0%; 95% confidence interval, 0% to 3.7%) tested positive by OraQuick ADVANCE, and all were confirmed to be uninfected by HIV-1 viral ribonucleic acid testing. One hundred eighteen of the 120 (98.3%) participants had a reactive HIV test for VISP/VISR: 77 (64%)Abstract: Background: Experimental human immunodeficiency virus (HIV)-1 vaccines frequently elicit antibodies against HIV-1 that may react with commonly used HIV diagnostic tests, a phenomenon known as vaccine-induced seropositivity/seroreactivity (VISP/VISR). We sought to determine, under clinic conditions, whether a patient-controlled HIV test, OraQuick ADVANCE Rapid HIV-1/2 Antibody Test, detected HIV-1 vaccine-induced antibodies. Methods: Plasma assessment of HIV-1 cross-reactivity was examined in end-of-study samples from 57 healthy, HIV-uninfected participants who received a candidate vaccine that has entered Phase 2B and 3 testing. We also screened 120 healthy, HIV-uninfected, unblinded HIV-1 vaccine participants with VISP/VISR for an assessment using saliva. These participants came from 21 different parent vaccine protocols representing 17 different vaccine regimens, all of which contained an HIV-1 envelope immunogen. OraQuick ADVANCE was compared with results from concurrent blood samples using a series of commercial HIV screening immunoassays. Results: Fifty-seven unique participant plasma samples were assayed in vitro, and only 1 (1.8%) was reactive by OraQuick ADVANCE. None of the 120 clinic participants (0%; 95% confidence interval, 0% to 3.7%) tested positive by OraQuick ADVANCE, and all were confirmed to be uninfected by HIV-1 viral ribonucleic acid testing. One hundred eighteen of the 120 (98.3%) participants had a reactive HIV test for VISP/VISR: 77 (64%) had at least 1 reactive fourth-generation HIV-1 diagnostic test ( P < .0001 vs no reactive OraQuick ADVANCE results), and 41 (34%) only had a reactive test by the less specific third-generation Abbott Prism assay. Conclusions: These data suggest that this widely available patient-controlled test has limited reactivity to HIV-1 antibodies elicited by these candidate HIV-1 vaccines. Abstract : Experimental HIV-1 vaccines frequently elicit antibodies which cross-react with common HIV diagnostic tests. Vaccine-induced seropositivity/seroreactivity (VISP/VISR) can be problematic for clinical trial volunteers. We tested a point-of-care HIV test, OraQuick ADVANCE, to determine if it could detect VISP/VISR. … (more)
- Is Part Of:
- Open forum infectious diseases. Volume 8:Number 1(2021)
- Journal:
- Open forum infectious diseases
- Issue:
- Volume 8:Number 1(2021)
- Issue Display:
- Volume 8, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 8
- Issue:
- 1
- Issue Sort Value:
- 2021-0008-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12-15
- Subjects:
- HIV diagnostics -- HIV vaccine -- immunogenicity -- vaccine safety
Communicable diseases -- Periodicals
Medical microbiology -- Periodicals
Infection -- Periodicals
616.9 - Journal URLs:
- http://ofid.oxfordjournals.org/ ↗
http://www.oxfordjournals.org/en/ ↗ - DOI:
- 10.1093/ofid/ofaa606 ↗
- Languages:
- English
- ISSNs:
- 2328-8957
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15807.xml