Short- and long-term functional results following drug-coated balloons versus drug- eluting stents in small coronary vessels: The RESTORE quantitative flow ratio study. (15th March 2021)
- Record Type:
- Journal Article
- Title:
- Short- and long-term functional results following drug-coated balloons versus drug- eluting stents in small coronary vessels: The RESTORE quantitative flow ratio study. (15th March 2021)
- Main Title:
- Short- and long-term functional results following drug-coated balloons versus drug- eluting stents in small coronary vessels: The RESTORE quantitative flow ratio study
- Authors:
- Li, Long
Guan, Changdong
Meng, Shuai
Bai, Yinxiao
Zhang, Zhihao
Zou, Kaiyuan
Ruan, Yang
Cao, Xiaojing
Jia, Ruofei
Guo, Caixia
Escaned, Javier
Jin, Zening
Xu, Bo - Abstract:
- Abstract: Background Immediate and long-term functional outcomes after percutaneous treatment of small vessel disease (SVD) with drug-coated balloon (DCB) versus drug-eluting stent (DES) remain unknown. The study sought to investigate whether treatment of de novo SVD with DCB yields similar functional results compared with DES, as judged with angiography-based quantitative flow ratio (QFR). Methods and results QFR was measured at pre-procedural, post-procedural and 9-month angiography in all available subjects from the non-inferiority RESTORE SVD China trial, in which patients were randomized to Restore DCB ( n = 116) or Resolute DES ( n = 114) study arms. Primary outcome of this analysis was 9-month QFR. Pre-procedural, post-procedural and 9-month QFR was performed in 84.8% (195/230), 83.0% (191/230) and 93.8% (181/193) cases, respectively. At 9 months, the QFR of DCB showed no significant difference to DES (0.88 ± 0.23 vs. 0.92 ± 0.12, p = 0.12). Both 9-month QFR and the QFR difference between post-procedure and 9-month follow-up were correlated with angiographic percentage of diameter stenosis and late loss, and predictive of 2-year clinical outcome. Conclusions Treatment of coronary SVD with DCB resulted in similar 9-month functional results compared with DES. This study provides evidences to the value of QFR as a mean of evaluating device performance after coronary revascularization. Clinical trial registration URL: https://www.clinicaltrials.gov ; ClinicalTrial.gov:Abstract: Background Immediate and long-term functional outcomes after percutaneous treatment of small vessel disease (SVD) with drug-coated balloon (DCB) versus drug-eluting stent (DES) remain unknown. The study sought to investigate whether treatment of de novo SVD with DCB yields similar functional results compared with DES, as judged with angiography-based quantitative flow ratio (QFR). Methods and results QFR was measured at pre-procedural, post-procedural and 9-month angiography in all available subjects from the non-inferiority RESTORE SVD China trial, in which patients were randomized to Restore DCB ( n = 116) or Resolute DES ( n = 114) study arms. Primary outcome of this analysis was 9-month QFR. Pre-procedural, post-procedural and 9-month QFR was performed in 84.8% (195/230), 83.0% (191/230) and 93.8% (181/193) cases, respectively. At 9 months, the QFR of DCB showed no significant difference to DES (0.88 ± 0.23 vs. 0.92 ± 0.12, p = 0.12). Both 9-month QFR and the QFR difference between post-procedure and 9-month follow-up were correlated with angiographic percentage of diameter stenosis and late loss, and predictive of 2-year clinical outcome. Conclusions Treatment of coronary SVD with DCB resulted in similar 9-month functional results compared with DES. This study provides evidences to the value of QFR as a mean of evaluating device performance after coronary revascularization. Clinical trial registration URL: https://www.clinicaltrials.gov ; ClinicalTrial.gov: Identifier: NCT02946307 . Highlights: Percutaneous revascularization in SVD with DCB resulted in a similar functional outcome with DES at 9-month follow-up. Performing QFR in small vessels is feasible and useful as a mean of evaluating device performance. Future studies may investigate QFR or QFR loss in combination with % diameter stenosis or late lumen loss as a surrogate endpoint. … (more)
- Is Part Of:
- International journal of cardiology. Volume 327(2021)
- Journal:
- International journal of cardiology
- Issue:
- Volume 327(2021)
- Issue Display:
- Volume 327, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 327
- Issue:
- 2021
- Issue Sort Value:
- 2021-0327-2021-0000
- Page Start:
- 45
- Page End:
- 51
- Publication Date:
- 2021-03-15
- Subjects:
- Quantitative flow ratio -- Drug-coated balloon -- Drug-eluting stent -- Percentage diameter stenosis -- Small vessel disease
Cardiology -- Periodicals
Electronic journals
616.12 - Journal URLs:
- http://www.clinicalkey.com/dura/browse/journalIssue/01675273 ↗
http://www.sciencedirect.com/science/journal/01675273 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.ijcard.2020.11.035 ↗
- Languages:
- English
- ISSNs:
- 0167-5273
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 4542.158000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File: