Specific risks of false decisions in conformity assessment of a substance or material with a mass balance constraint – A case study of potassium iodate. (March 2021)
- Record Type:
- Journal Article
- Title:
- Specific risks of false decisions in conformity assessment of a substance or material with a mass balance constraint – A case study of potassium iodate. (March 2021)
- Main Title:
- Specific risks of false decisions in conformity assessment of a substance or material with a mass balance constraint – A case study of potassium iodate
- Authors:
- Pennecchi, Francesca R.
Kuselman, Ilya
Di Rocco, Aglaia
Brynn Hibbert, D.
Sobina, Alena
Sobina, Egor - Abstract:
- Graphical abstract: Total specific consumer's risk R c ∗ (a) and producer's risk R p ∗ (b) in dependence on measured directly purity c 1mD and impurities content c 2mD . Highlights: Specific risks in a material conformity assessment are studied at a mass balance constraint. A Bayesian evaluation of total specific risks due to measurement uncertainty is developed. A Monte Carlo method taking into account the mass balance constraint is applied. Specific risks in the assessment of a potassium iodate purity are evaluated as a case study. Abstract: A methodology for the Bayesian evaluation of total specific risks of false decisions on conformity of a substance or material due to measurement uncertainty was developed using Monte Carlo simulations, taking into account the mass balance constraint of the data. As a case study, the measurement results (measured values and associated measurement uncertainty) obtained for testing a potassium iodate batch, being considered as a candidate reference material of potassium iodate purity, were analyzed and discussed for different models of the prior probability density function and the likelihood function. Different scenarios of the risks related to determination of potassium iodate purity were studied, when the direct or indirect test method is applied, as well as when both are used simultaneously.
- Is Part Of:
- Measurement. Volume 173(2021)
- Journal:
- Measurement
- Issue:
- Volume 173(2021)
- Issue Display:
- Volume 173, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 173
- Issue:
- 2021
- Issue Sort Value:
- 2021-0173-2021-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-03
- Subjects:
- Conformity assessment -- Mass balance constraint -- Bayesian multivariate modelling -- Monte Carlo method -- Specific risks -- Potassium iodate
Weights and measures -- Periodicals
Measurement -- Periodicals
Measurement
Weights and measures
Periodicals
530.8 - Journal URLs:
- http://www.sciencedirect.com/science/journal/02632241 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.measurement.2020.108662 ↗
- Languages:
- English
- ISSNs:
- 0263-2241
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5413.544700
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15795.xml