Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint. (March 2021)
- Record Type:
- Journal Article
- Title:
- Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint. (March 2021)
- Main Title:
- Validity and intra-examiner reliability of the Hawk goniometer versus the universal goniometer for the measurement of range of motion of the glenohumeral joint
- Authors:
- Pérez-de la Cruz, Sagrario
de León, Óscar Arellano
Mallada, Néstor Pérez
Rodríguez, Antonio Vargas - Abstract:
- Highlights: Data on shoulder range of motion is important for optimal treatment programming. No significant differences exist between the values measured with both devices. The Hawk goniometer is appropriate for measuring shoulder joint range of motion. Abstract: Aim: The aim of this study was to establish the validity of an external measurement system (the Hawk goniometer). This is a digital device which measures joint ranges compared to the universal goniometer for the measurement of shoulder range of motion in healthy adults. Material and methods: a correlational study with 157 healthy volunteers completed six shoulder movements (forward flexion, abduction, extension, adduction and internal and external rotation) with each shoulder. The degree of agreement between each goniometer and Hawk measurement was assessed using Intra-class Correlation Coefficients (ICC) and Bland-Altman 95% limits of agreement (LOA). Results: the tests showed a very strong relationship between the readings of both devices (CI between 0.81 and 0.99) and there were no significant differences between the mean readings of both devices. An intraclass correlation coefficient (ICC) of above 0.9 was obtained, indicating a high intra-evaluator reliability of the Hawk goniometer in repeated measurements of shoulder range of motion. Conclusions: the Hawk goniometer is a valid and reliable element for the objective measurement of the range of motion at the shoulder joint.
- Is Part Of:
- Medical engineering & physics. Volume 89(2021)
- Journal:
- Medical engineering & physics
- Issue:
- Volume 89(2021)
- Issue Display:
- Volume 89, Issue 2021 (2021)
- Year:
- 2021
- Volume:
- 89
- Issue:
- 2021
- Issue Sort Value:
- 2021-0089-2021-0000
- Page Start:
- 7
- Page End:
- 11
- Publication Date:
- 2021-03
- Subjects:
- Hawk goniometer -- Universal goniometer -- Range of motion -- Assessment -- Shoulder
Biomedical engineering -- Periodicals
Biomedical Engineering -- Periodicals
Physics -- Periodicals
Génie biomédical -- Périodiques
Biomedical engineering
Electronic journals
Periodicals
610.28 - Journal URLs:
- http://www.medengphys.com ↗
http://www.sciencedirect.com/science/journal/13504533 ↗
http://www.clinicalkey.com/dura/browse/journalIssue/13504533 ↗
http://www.clinicalkey.com.au/dura/browse/journalIssue/13504533 ↗
http://www.elsevier.com/journals ↗ - DOI:
- 10.1016/j.medengphy.2021.01.005 ↗
- Languages:
- English
- ISSNs:
- 1350-4533
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5527.323000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15805.xml