Performance of deep learning synthetic CTs for MR‐only brain radiation therapy. Issue 1 (7th January 2021)
- Record Type:
- Journal Article
- Title:
- Performance of deep learning synthetic CTs for MR‐only brain radiation therapy. Issue 1 (7th January 2021)
- Main Title:
- Performance of deep learning synthetic CTs for MR‐only brain radiation therapy
- Authors:
- Liu, Xiaoning
Emami, Hajar
Nejad‐Davarani, Siamak P.
Morris, Eric
Schultz, Lonni
Dong, Ming
K. Glide‐Hurst, Carri - Abstract:
- Abstract: Purpose: To evaluate the dosimetric and image‐guided radiation therapy (IGRT) performance of a novel generative adversarial network (GAN) generated synthetic CT (synCT) in the brain and compare its performance for clinical use including conventional brain radiotherapy, cranial stereotactic radiosurgery (SRS), planar, and volumetric IGRT. Methods and Materials: SynCT images for 12 brain cancer patients (6 SRS, 6 conventional) were generated from T1‐weighted postgadolinium magnetic resonance (MR) images by applying a GAN model with a residual network (ResNet) generator and a convolutional neural network (CNN) with 5 convolutional layers as the discriminator that classified input images as real or synthetic. Following rigid registration, clinical structures and treatment plans derived from simulation CT (simCT) images were transferred to synCTs. Dose was recalculated for 15 simCT/synCT plan pairs using fixed monitor units. Two‐dimensional (2D) gamma analysis (2%/2 mm, 1%/1 mm) was performed to compare dose distributions at isocenter. Dose–volume histogram (DVH) metrics (D95%, D99%, D0.2cc, and D0.035cc ) were assessed for the targets and organ at risks (OARs). IGRT performance was evaluated via volumetric registration between cone beam CT (CBCT) to synCT/simCT and planar registration between KV images to synCT/simCT digital reconstructed radiographs (DRRs). Results: Average gamma passing rates at 1%/1mm and 2%/2mm were 99.0 ± 1.5% and 99.9 ± 0.2%, respectively.Abstract: Purpose: To evaluate the dosimetric and image‐guided radiation therapy (IGRT) performance of a novel generative adversarial network (GAN) generated synthetic CT (synCT) in the brain and compare its performance for clinical use including conventional brain radiotherapy, cranial stereotactic radiosurgery (SRS), planar, and volumetric IGRT. Methods and Materials: SynCT images for 12 brain cancer patients (6 SRS, 6 conventional) were generated from T1‐weighted postgadolinium magnetic resonance (MR) images by applying a GAN model with a residual network (ResNet) generator and a convolutional neural network (CNN) with 5 convolutional layers as the discriminator that classified input images as real or synthetic. Following rigid registration, clinical structures and treatment plans derived from simulation CT (simCT) images were transferred to synCTs. Dose was recalculated for 15 simCT/synCT plan pairs using fixed monitor units. Two‐dimensional (2D) gamma analysis (2%/2 mm, 1%/1 mm) was performed to compare dose distributions at isocenter. Dose–volume histogram (DVH) metrics (D95%, D99%, D0.2cc, and D0.035cc ) were assessed for the targets and organ at risks (OARs). IGRT performance was evaluated via volumetric registration between cone beam CT (CBCT) to synCT/simCT and planar registration between KV images to synCT/simCT digital reconstructed radiographs (DRRs). Results: Average gamma passing rates at 1%/1mm and 2%/2mm were 99.0 ± 1.5% and 99.9 ± 0.2%, respectively. Excellent agreement in DVH metrics was observed (mean difference ≤0.10 ± 0.04 Gy for targets, 0.13 ± 0.04 Gy for OARs). The population averaged mean difference in CBCT‐synCT registrations were <0.2 mm and 0.1 degree different from simCT‐based registrations. The mean difference between kV‐synCT DRR and kV‐simCT DRR registrations was <0.5 mm with no statistically significant differences observed ( P > 0.05). An outlier with a large resection cavity exhibited the worst‐case scenario. Conclusion: Brain GAN synCTs demonstrated excellent performance for dosimetric and IGRT endpoints, offering potential use in high precision brain cancer therapy. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 1(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 1(2021)
- Issue Display:
- Volume 22, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2021-0022-0001-0000
- Page Start:
- 308
- Page End:
- 317
- Publication Date:
- 2021-01-07
- Subjects:
- Deep Learning -- General Adversarial Network -- Image Guided Radiation Therapy -- Synthetic CT
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13139 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15783.xml