Spatial and dosimetric evaluation of residual distortions of prostate and seminal vesicle bed after image‐guided definitive and postoperative radiotherapy of prostate cancer with endorectal balloon. Issue 1 (30th December 2020)
- Record Type:
- Journal Article
- Title:
- Spatial and dosimetric evaluation of residual distortions of prostate and seminal vesicle bed after image‐guided definitive and postoperative radiotherapy of prostate cancer with endorectal balloon. Issue 1 (30th December 2020)
- Main Title:
- Spatial and dosimetric evaluation of residual distortions of prostate and seminal vesicle bed after image‐guided definitive and postoperative radiotherapy of prostate cancer with endorectal balloon
- Authors:
- Levegrün, Sabine
Pöttgen, Christoph
Xydis, Konstantinos
Guberina, Maja
Abu Jawad, Jehad
Stuschke, Martin - Abstract:
- Abstract: Purpose: To quantify daily residual deviations from the planned geometry after image‐guided prostate radiotherapy with endorectal balloon and to evaluate their effect on the delivered dose distribution. Methods: Daily kV‐CBCT imaging was used for online setup‐correction in six degrees of freedom (6‐dof) for 24 patients receiving definitive (12 RTdef patients) or postoperative (12 RTpostop patients) radiotherapy with endorectal balloon (overall 739 CBCTs). Residual deviations were evaluated using several spatial and dosimetric variables, including: (a) posterior Hausdorff distance HD post (=maximum distance between planned and daily CTV contour), (b) point Pworst with largest HD post over all fractions, (c) equivalent uniform dose using a cell survival model (EUDSF ) and the generalized EUD concept (gEUDa with parameter a = −7 and a = −20). EUD values were determined for planned ( EUD SF plan ), daily ( EUD SF ind ), and delivered dose distributions ( EUD SF accum ) for plans with 6 mm (=clinical plans) and 2 mm CTV‐to‐PTV margin. Time series analyses of interfractional spatial and dosimetric deviations were conducted. Results: Large HD post values ≥ 12.5 mm (≥15 mm) were observed in 20/739 (5/739) fractions distributed across 7 (3) patients. Points Pworst were predominantly located at the posterior CTV boundary in the seminal vesicle region (16/24 patients, 6/7 patients with HD post ≥ 12.5 mm). Time series analyses revealed a stationary white noise characteristicAbstract: Purpose: To quantify daily residual deviations from the planned geometry after image‐guided prostate radiotherapy with endorectal balloon and to evaluate their effect on the delivered dose distribution. Methods: Daily kV‐CBCT imaging was used for online setup‐correction in six degrees of freedom (6‐dof) for 24 patients receiving definitive (12 RTdef patients) or postoperative (12 RTpostop patients) radiotherapy with endorectal balloon (overall 739 CBCTs). Residual deviations were evaluated using several spatial and dosimetric variables, including: (a) posterior Hausdorff distance HD post (=maximum distance between planned and daily CTV contour), (b) point Pworst with largest HD post over all fractions, (c) equivalent uniform dose using a cell survival model (EUDSF ) and the generalized EUD concept (gEUDa with parameter a = −7 and a = −20). EUD values were determined for planned ( EUD SF plan ), daily ( EUD SF ind ), and delivered dose distributions ( EUD SF accum ) for plans with 6 mm (=clinical plans) and 2 mm CTV‐to‐PTV margin. Time series analyses of interfractional spatial and dosimetric deviations were conducted. Results: Large HD post values ≥ 12.5 mm (≥15 mm) were observed in 20/739 (5/739) fractions distributed across 7 (3) patients. Points Pworst were predominantly located at the posterior CTV boundary in the seminal vesicle region (16/24 patients, 6/7 patients with HD post ≥ 12.5 mm). Time series analyses revealed a stationary white noise characteristic of HD post and relative dose at Pworst . The EUDSF difference between planned and accumulated dose distributions was < 5.4% for all 6‐mm plans. Evaluating 2‐mm plans, EUDSF deteriorated by < 10% (<5%) in 75% (58.5%) of the patients. EUD SF accum was well described by the median value of the EUD SF ind distribution. PTV margin calculation at Pworst yielded 8.8 mm. Conclusions: Accumulated dose distributions in prostate radiotherapy with endorectal balloon are forgiving of considerable residual distortions after 6‐dof patient setup if they are observed in a minority of fractions and the median value of EUD SF ind determined per fraction stays within 95% of prescribed dose. Common PTV margin calculations are overly conservative because after online correction of translational and rotational errors only residual deformations need to be included. These results provide guidelines regarding online navigation, margin optimization, and treatment adaptation strategies. … (more)
- Is Part Of:
- Journal of applied clinical medical physics. Volume 22:Issue 1(2021)
- Journal:
- Journal of applied clinical medical physics
- Issue:
- Volume 22:Issue 1(2021)
- Issue Display:
- Volume 22, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 22
- Issue:
- 1
- Issue Sort Value:
- 2021-0022-0001-0000
- Page Start:
- 226
- Page End:
- 241
- Publication Date:
- 2020-12-30
- Subjects:
- accumulated dose distributions -- image‐guided radiotherapy -- prostate cancer -- residual distortions -- time series
Medical physics -- Periodicals
Clinical medicine -- Periodicals
Health Physics
Clinical Medicine
Electronic journals
Periodicals
Periodicals
Fulltext
Internet Resources
610.153 - Journal URLs:
- http://aapm.onlinelibrary.wiley.com/hub/journal/10.1002/(ISSN)1526-9914/ ↗
http://bibpurl.oclc.org/web/7294 ↗
http://www.jacmp.org/ ↗
http://onlinelibrary.wiley.com/ ↗ - DOI:
- 10.1002/acm2.13138 ↗
- Languages:
- English
- ISSNs:
- 1526-9914
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15783.xml