Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis. Issue 3 (22nd January 2021)
- Record Type:
- Journal Article
- Title:
- Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging: A systematic review with diagnostic meta-analysis. Issue 3 (22nd January 2021)
- Main Title:
- Diagnostic accuracy of different computer-aided diagnostic systems for prostate cancer based on magnetic resonance imaging
- Authors:
- Xing, Xiping
Zhao, Xinke
Wei, Huiping
Li, Yingdong - Other Names:
- Ding. Jianxun section editor.
- Abstract:
- Abstract: Background: Computer-aided detection (CAD) system for accurate and automated prostate cancer (PCa) diagnosis have been developed, however, the diagnostic test accuracy of different CAD systems is still controversial. This systematic review aimed to assess the diagnostic accuracy of CAD systems based on magnetic resonance imaging for PCa. Methods: Cochrane library, PubMed, EMBASE and China Biology Medicine disc were systematically searched until March 2019 for original diagnostic studies. Two independent reviewers selected studies on CAD based on magnetic resonance imaging diagnosis of PCa and extracted the requisite data. Pooled sensitivity, specificity, and the area under the summary receiver operating characteristic curve were calculated to estimate the diagnostic accuracy of CAD system. Results: Fifteen studies involving 1945 patients were included in our analysis. The diagnostic meta-analysis showed that overall sensitivity of CAD system ranged from 0.47 to 1.00 and, specificity from 0.47 to 0.89. The pooled sensitivity of CAD system was 0.87 (95% CI: 0.76–0.94), pooled specificity 0.76 (95% CI: 0.62–0.85), and the area under curve (AUC) 0.89 (95% CI: 0.86–0.91). Subgroup analysis showed that the support vector machines produced the best AUC among the CAD classifiers, with sensitivity ranging from 0.87 to 0.92, and specificity from 0.47 to 0.95. Among different zones of prostate, CAD system produced the best AUC in the transitional zone than the peripheral zoneAbstract: Background: Computer-aided detection (CAD) system for accurate and automated prostate cancer (PCa) diagnosis have been developed, however, the diagnostic test accuracy of different CAD systems is still controversial. This systematic review aimed to assess the diagnostic accuracy of CAD systems based on magnetic resonance imaging for PCa. Methods: Cochrane library, PubMed, EMBASE and China Biology Medicine disc were systematically searched until March 2019 for original diagnostic studies. Two independent reviewers selected studies on CAD based on magnetic resonance imaging diagnosis of PCa and extracted the requisite data. Pooled sensitivity, specificity, and the area under the summary receiver operating characteristic curve were calculated to estimate the diagnostic accuracy of CAD system. Results: Fifteen studies involving 1945 patients were included in our analysis. The diagnostic meta-analysis showed that overall sensitivity of CAD system ranged from 0.47 to 1.00 and, specificity from 0.47 to 0.89. The pooled sensitivity of CAD system was 0.87 (95% CI: 0.76–0.94), pooled specificity 0.76 (95% CI: 0.62–0.85), and the area under curve (AUC) 0.89 (95% CI: 0.86–0.91). Subgroup analysis showed that the support vector machines produced the best AUC among the CAD classifiers, with sensitivity ranging from 0.87 to 0.92, and specificity from 0.47 to 0.95. Among different zones of prostate, CAD system produced the best AUC in the transitional zone than the peripheral zone and central gland; sensitivity ranged from 0.89 to 1.00, and specificity from 0.38 to 0.85. Conclusions: CAD system can help improve the diagnostic accuracy of PCa especially using the support vector machines classifier. Whether the performance of the CAD system depends on the specific locations of the prostate needs further investigation. … (more)
- Is Part Of:
- Medicine. Volume 100:Issue 3(2021)
- Journal:
- Medicine
- Issue:
- Volume 100:Issue 3(2021)
- Issue Display:
- Volume 100, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 100
- Issue:
- 3
- Issue Sort Value:
- 2021-0100-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-22
- Subjects:
- Computer-aided detection -- diagnostic accuracy -- magnetic resonance imaging -- meta-analysis -- prostate cancer -- systematic review
Medicine -- Periodicals
Medicine -- Periodicals
Médecine -- Périodiques
Geneeskunde
Medicine
Periodicals
Periodicals
610.5 - Journal URLs:
- http://journals.lww.com/md-journal/pages/default.aspx ↗
http://gateway.ovid.com/ovidweb.cgi?T=JS&PAGE=toc&D=ovft&MODE=ovid&NEWS=N&AN=00002060-000000000-00000 ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/MD.0000000000023817 ↗
- Languages:
- English
- ISSNs:
- 0025-7974
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 5534.000000
British Library DSC - BLDSS-3PM
British Library STI - ELD Digital store - Ingest File:
- 15732.xml