Braces Designed Using CAD/CAM Combined or Not With Finite Element Modeling Lead to Effective Treatment and Quality of Life After 2 Years: A Randomized Controlled Trial. Issue 1 (1st January 2021)
- Record Type:
- Journal Article
- Title:
- Braces Designed Using CAD/CAM Combined or Not With Finite Element Modeling Lead to Effective Treatment and Quality of Life After 2 Years: A Randomized Controlled Trial. Issue 1 (1st January 2021)
- Main Title:
- Braces Designed Using CAD/CAM Combined or Not With Finite Element Modeling Lead to Effective Treatment and Quality of Life After 2 Years
- Authors:
- Guy, Aymeric
Labelle, Hubert
Barchi, Soraya
Audet-Duchesne, Elisabeth
Cobetto, Nikita
Parent, Stefan
Raison, Maxime
Aubin, Carl-Éric - Abstract:
- Abstract : Study Design: Single-center prospective randomized controlled trial. Objective: The aim of this study was to assess the computer-aided design/manufacturing (CAD/CAM) brace design approach, with and without added finite element modeling (FEM) simulations, after 2 years in terms of clinical outcomes, 3D correction, compliance, and quality of life (QoL). Summary of Background Data: Previous studies demonstrated that braces designed using a combination of CAD/CAM and FEM induced promising in-brace corrections, were lighter, thinner, and covered less trunk surface. Yet, their long-term impact on treatment quality has not been evaluated. Methods: One-hundred twenty adolescent idiopathic scoliosis patients were recruited following Scoliosis Research Society standardized criteria for brace treatment; 61 patients in the first subgroup (CAD) were given braces designed using CAD/CAM; 59 in the second subgroup (CAD-FEM) received braces additionally simulated and refined using a patient-specific FEM built from 3D reconstructions of the spine, rib cage and pelvis. Main thoracic (MT) and thoraco-lumbar/lumbar (TL/L) Cobb angles, sagittal curves, and apical rotations were compared at the initial visit and after 2 years. Patient compliance and QoL were tracked respectively by using embedded temperature sensors and SRS-22r questionnaires. Results: Forty-four patients with CAD-FEM braces and 50 with CAD braces completed the study. Average in-brace correction was 9° MT (8° CAD-FEM,Abstract : Study Design: Single-center prospective randomized controlled trial. Objective: The aim of this study was to assess the computer-aided design/manufacturing (CAD/CAM) brace design approach, with and without added finite element modeling (FEM) simulations, after 2 years in terms of clinical outcomes, 3D correction, compliance, and quality of life (QoL). Summary of Background Data: Previous studies demonstrated that braces designed using a combination of CAD/CAM and FEM induced promising in-brace corrections, were lighter, thinner, and covered less trunk surface. Yet, their long-term impact on treatment quality has not been evaluated. Methods: One-hundred twenty adolescent idiopathic scoliosis patients were recruited following Scoliosis Research Society standardized criteria for brace treatment; 61 patients in the first subgroup (CAD) were given braces designed using CAD/CAM; 59 in the second subgroup (CAD-FEM) received braces additionally simulated and refined using a patient-specific FEM built from 3D reconstructions of the spine, rib cage and pelvis. Main thoracic (MT) and thoraco-lumbar/lumbar (TL/L) Cobb angles, sagittal curves, and apical rotations were compared at the initial visit and after 2 years. Patient compliance and QoL were tracked respectively by using embedded temperature sensors and SRS-22r questionnaires. Results: Forty-four patients with CAD-FEM braces and 50 with CAD braces completed the study. Average in-brace correction was 9° MT (8° CAD-FEM, 10° CAD, P = 0.054) and 12° TL/L (same for both subgroups, P = 0.91). Out-of-brace 2-year progression from initial deformity was <4° for all 3D measurements. Sixty-six percent of all cases (30 CAD-FEM, 35 CAD) met the ⩽5° curve progression criterion, 83% (38 CAD-FEM, 43 CAD) stayed <45°, and 6% (5 CAD-FEM, 1 CAD) underwent fusion surgery. 3D correction, compliance, and QoL were not significantly different between both subgroups ( P > 0.05). Conclusion: After 2 years, patients with braces designed using CAD/CAM with/without FEM had satisfying clinical outcomes (compared to the BrAIST study), 3D corrections, compliance and QoL. A more comprehensive optimization of brace treatment remains to be accomplished. Level of Evidence: 2 Abstract : The impact of brace design through CAD/CAM with or without finite element modeling was studied over 2 years in a randomized controlled trial. Clinical outcomes, 3D correction, compliance and quality of life were satisfactory and equivalent between the computational techniques used, demonstrating the validity of simulation in the design process. … (more)
- Is Part Of:
- Spine. Volume 46:Issue 1(2021)
- Journal:
- Spine
- Issue:
- Volume 46:Issue 1(2021)
- Issue Display:
- Volume 46, Issue 1 (2021)
- Year:
- 2021
- Volume:
- 46
- Issue:
- 1
- Issue Sort Value:
- 2021-0046-0001-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-01
- Subjects:
- 3D correction -- adherence -- adolescent idiopathic scoliosis (AIS) -- brace simulation -- brace-wear compliance -- bracing -- computer-assisted design and manufacturing (CAD/CAM) -- finite element modeling (FEM) -- quality of life -- randomized controlled trial (RCT)
Spine -- Abnormalities -- Periodicals
Spine -- Diseases -- Periodicals
Spine -- Surgery -- Periodicals
616.73005 - Journal URLs:
- http://gateway.ovid.com/ovidweb.cgi?T=JS&MODE=ovid&NEWS=n&PAGE=toc&D=ovft&AN=00007632-000000000-00000 ↗
http://journals.lww.com/spinejournal/pages/default.aspx ↗
http://www.spinejournal.com/ ↗
http://journals.lww.com ↗ - DOI:
- 10.1097/BRS.0000000000003705 ↗
- Languages:
- English
- ISSNs:
- 0362-2436
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 8413.903000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15744.xml