Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls. (May 2021)
- Record Type:
- Journal Article
- Title:
- Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls. (May 2021)
- Main Title:
- Hygrothermal performance of six insulation systems for internal retrofitting solid masonry walls
- Authors:
- Jensen, Nickolaj Feldt
Bjarløv, Søren Peter
Rode, Carsten
Andersen, Birgitte
Møller, Eva B - Other Names:
- Kalamees Targo guest-editor.
Derome BDominique guest-editor. - Abstract:
- The study investigated the hygrothermal performance and risk of fungal growth in a phenolic foam system with a closed cell structure and a diffusion-open and capillary active lime-cork based insulating plaster, for internal retrofitting purposes. The setup comprised two 40-feet (12.2 m) insulated reefer container with controlled indoor climate, reconfigured with 24 holes (1 × 2 m each) containing solid masonry walls with embedded wooden elements on the interior side. Focus was on the conditions in the masonry/insulation interface and embedded wooden elements, and the performance of the two systems were compared to three diffusion-open insulation systems and one diffusion-tight. The effect of exterior hydrophobisation was also investigated. Relative humidity and temperature were measured in several locations in the test walls over 2½ years, and the risk of fungal growth was evaluated by on-site measurements and the VTT mould-growth model. The findings indicate that internally insulated walls with bare brick exterior surfaces performed poorly with high risk of fungal growth. The effect of exterior hydrophobisation was found to vary with the orientation and the installed insulation system, with a generally positive effect on walls facing south-west but limited effect for north-east. Furthermore, the more diffusion-tight insulation systems were found to perform better in combination with exterior hydrophobisation than the highly diffusion-open systems. The lime-cork insulatingThe study investigated the hygrothermal performance and risk of fungal growth in a phenolic foam system with a closed cell structure and a diffusion-open and capillary active lime-cork based insulating plaster, for internal retrofitting purposes. The setup comprised two 40-feet (12.2 m) insulated reefer container with controlled indoor climate, reconfigured with 24 holes (1 × 2 m each) containing solid masonry walls with embedded wooden elements on the interior side. Focus was on the conditions in the masonry/insulation interface and embedded wooden elements, and the performance of the two systems were compared to three diffusion-open insulation systems and one diffusion-tight. The effect of exterior hydrophobisation was also investigated. Relative humidity and temperature were measured in several locations in the test walls over 2½ years, and the risk of fungal growth was evaluated by on-site measurements and the VTT mould-growth model. The findings indicate that internally insulated walls with bare brick exterior surfaces performed poorly with high risk of fungal growth. The effect of exterior hydrophobisation was found to vary with the orientation and the installed insulation system, with a generally positive effect on walls facing south-west but limited effect for north-east. Furthermore, the more diffusion-tight insulation systems were found to perform better in combination with exterior hydrophobisation than the highly diffusion-open systems. The lime-cork insulating plaster showed high relative humidity and risk of moisture-induced problems. The on-site fungal tests showed no growth in the masonry/insulation interface inside the two insulation systems, probably due to high initial pH-value. … (more)
- Is Part Of:
- Journal of building physics. Volume 44:Number 6(2021)
- Journal:
- Journal of building physics
- Issue:
- Volume 44:Number 6(2021)
- Issue Display:
- Volume 44, Issue 6 (2021)
- Year:
- 2021
- Volume:
- 44
- Issue:
- 6
- Issue Sort Value:
- 2021-0044-0006-0000
- Page Start:
- 539
- Page End:
- 573
- Publication Date:
- 2021-05
- Subjects:
- Internal insulation -- solid masonry -- field study -- hydrophobisation -- mould modelling -- on-site mould observations
Buildings -- Environmental engineering -- Periodicals
Insulation (Heat) -- Periodicals
693.8 - Journal URLs:
- http://jen.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/1744259120988745 ↗
- Languages:
- English
- ISSNs:
- 1744-2591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15723.xml