Individualized positive end-expiratory pressure setting in patients with severe acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation. (May 2021)
- Record Type:
- Journal Article
- Title:
- Individualized positive end-expiratory pressure setting in patients with severe acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation. (May 2021)
- Main Title:
- Individualized positive end-expiratory pressure setting in patients with severe acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation
- Authors:
- Yin, Chengfen
Gao, Xinjing
Cao, Chao
Xu, Lei
Lu, Xing - Abstract:
- Background: Patients with acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation benefit from higher positive end-expiratory pressure combined with conventional ventilation during the early extracorporeal membrane oxygenation period. The role of incremental positive end-expiratory pressure titration in patients with severe acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation remains unclear. This study aimed to determine the preferred method for setting positive end-expiratory pressure in patients with severe acute respiratory distress syndrome on veno-venous extracorporeal membrane oxygenation support. Methods: We retrospectively reviewed all subjects supported with veno-venous extracorporeal membrane oxygenation for severe acute respiratory distress syndrome from 2009 to 2019 in the intensive care units in Tianjin Third Central Hospital. Subjects were divided into two groups according to the positive end-expiratory pressure titration method used: P-V curve (quasi-static pressure-volume curve-guided positive end-expiratory pressure setting) group or Crs (respiratory system compliance-guided positive end-expiratory pressure setting) group. Results: Forty-three subjects were included in the clinical outcome analysis: 20 in the P-V curve group and 23 in the Crs group. Initial positive end-expiratory pressure levels during veno-venous extracorporeal membrane oxygenation were similar inBackground: Patients with acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation benefit from higher positive end-expiratory pressure combined with conventional ventilation during the early extracorporeal membrane oxygenation period. The role of incremental positive end-expiratory pressure titration in patients with severe acute respiratory distress syndrome supported with veno-venous extracorporeal membrane oxygenation remains unclear. This study aimed to determine the preferred method for setting positive end-expiratory pressure in patients with severe acute respiratory distress syndrome on veno-venous extracorporeal membrane oxygenation support. Methods: We retrospectively reviewed all subjects supported with veno-venous extracorporeal membrane oxygenation for severe acute respiratory distress syndrome from 2009 to 2019 in the intensive care units in Tianjin Third Central Hospital. Subjects were divided into two groups according to the positive end-expiratory pressure titration method used: P-V curve (quasi-static pressure-volume curve-guided positive end-expiratory pressure setting) group or Crs (respiratory system compliance-guided positive end-expiratory pressure setting) group. Results: Forty-three subjects were included in the clinical outcome analysis: 20 in the P-V curve group and 23 in the Crs group. Initial positive end-expiratory pressure levels during veno-venous extracorporeal membrane oxygenation were similar in both groups. Incidence rates of barotrauma and hemodynamic events were significantly lower in the Crs group (all p < 0.05). Mechanical ventilation duration, intensive care unit length of stay, and hospital length of stay were significantly shorter in the Crs group than the P-V curve group (all p < 0.05). Subjects in the Crs group showed non-significant improvements in the duration of extracorporeal membrane oxygenation support and 28-day mortality (p > 0.05). Conclusion: Respiratory system compliance-guided positive end-expiratory pressure setting may lead to more optimal clinical outcomes for patients with severe acute respiratory distress syndrome supported by veno-venous extracorporeal membrane oxygenation. Moreover, the operation is simple, safe, and convenient in clinical practice. … (more)
- Is Part Of:
- Perfusion. Volume 36:Number 4(2021)
- Journal:
- Perfusion
- Issue:
- Volume 36:Number 4(2021)
- Issue Display:
- Volume 36, Issue 4 (2021)
- Year:
- 2021
- Volume:
- 36
- Issue:
- 4
- Issue Sort Value:
- 2021-0036-0004-0000
- Page Start:
- 374
- Page End:
- 381
- Publication Date:
- 2021-05
- Subjects:
- veno-venous extracorporeal membrane oxygenation -- severe acute respiratory distress syndrome -- positive end-expiratory pressure -- quasi-static pressure-volume curve-guided positive end-expiratory pressure setting -- respiratory system compliance-guided positive end-expiratory pressure setting -- intensive care unit -- mechanical ventilation
Perfusion (Physiology) -- Periodicals
Blood -- Circulation, Artificial -- Periodicals
Heart -- Surgery -- Periodicals
Extracorporeal Circulation -- Periodicals
Perfusion -- Periodicals
Circulation extracorporelle -- Périodiques
Perfusion -- Périodiques
617.41 - Journal URLs:
- http://prf.sagepub.com/ ↗
http://www.uk.sagepub.com/home.nav ↗ - DOI:
- 10.1177/0267659120946728 ↗
- Languages:
- English
- ISSNs:
- 0267-6591
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15721.xml