Simultaneous detection of Streptococcuspneumoniae and prevention of carryover contamination using multiple cross displacement amplification with Antarctic thermal sensitive uracil-DNA-glycosylase and a lateral flow biosensor. Issue 3 (19th January 2021)
- Record Type:
- Journal Article
- Title:
- Simultaneous detection of Streptococcuspneumoniae and prevention of carryover contamination using multiple cross displacement amplification with Antarctic thermal sensitive uracil-DNA-glycosylase and a lateral flow biosensor. Issue 3 (19th January 2021)
- Main Title:
- Simultaneous detection of Streptococcuspneumoniae and prevention of carryover contamination using multiple cross displacement amplification with Antarctic thermal sensitive uracil-DNA-glycosylase and a lateral flow biosensor
- Authors:
- Yan, Linlin
Zhao, Fan
Niu, Lina
Cai, Yu
Wu, Lei
Zhu, Xiaoxue
Nong, Jinqing
Hu, Shoukui - Abstract:
- ABSTRACT: Streptococcus pneumoniae is an important clinical pathogenic bacterium that is the primary cause of meningitis, septicemia and community-acquired pneumonia. The mortality rate of pneumococcal disease is high, especially in children younger than 5-years-old. Rapid and accurate detection of S . pneumoniae is critical for clinical diagnosis. A ply gene-based multiple cross displacement amplification (MCDA) assay, amplifying DNA under 65°C for 40 min, was established to detect S . pneumoniae . Antarctic thermal sensitive uracil-DNA-glycosylase (AUDG) was applied to prevent carryover contamination. A lateral flow biosensor (LFB) was used to indicate the MCDA results. The ply -MCDA assay could detect as low as 10 fg of S. pneumoniae DNA and 447 colony forming units (CFU)/mL of spiked sputum samples. The analytical sensitivity of the ply -MCDA assay to detect clinical specimens was 100 times higher than that of PCR. The specificity of the ply -MCDA assay was evaluated using 15 S . pneumoniae strains and 25 non- S. pneumoniae strains, which confirmed the high selectivity of the ply -MCDA assay for S . pneumoniae . The AUDG enzyme could effectively eliminate carryover contamination and thus prevented false-positive results. In conclusion, ply -AUDG-MCDA-LFB is a simple, rapid and accurate method to detect S . pneumoniae . Abstract : Simultaneous Streptococcus pneumoniae detection and elimination of carryover contamination with Antarctic thermal sensitiveABSTRACT: Streptococcus pneumoniae is an important clinical pathogenic bacterium that is the primary cause of meningitis, septicemia and community-acquired pneumonia. The mortality rate of pneumococcal disease is high, especially in children younger than 5-years-old. Rapid and accurate detection of S . pneumoniae is critical for clinical diagnosis. A ply gene-based multiple cross displacement amplification (MCDA) assay, amplifying DNA under 65°C for 40 min, was established to detect S . pneumoniae . Antarctic thermal sensitive uracil-DNA-glycosylase (AUDG) was applied to prevent carryover contamination. A lateral flow biosensor (LFB) was used to indicate the MCDA results. The ply -MCDA assay could detect as low as 10 fg of S. pneumoniae DNA and 447 colony forming units (CFU)/mL of spiked sputum samples. The analytical sensitivity of the ply -MCDA assay to detect clinical specimens was 100 times higher than that of PCR. The specificity of the ply -MCDA assay was evaluated using 15 S . pneumoniae strains and 25 non- S. pneumoniae strains, which confirmed the high selectivity of the ply -MCDA assay for S . pneumoniae . The AUDG enzyme could effectively eliminate carryover contamination and thus prevented false-positive results. In conclusion, ply -AUDG-MCDA-LFB is a simple, rapid and accurate method to detect S . pneumoniae . Abstract : Simultaneous Streptococcus pneumoniae detection and elimination of carryover contamination with Antarctic thermal sensitive uracil-DNA-glycosylase-supplemented multiple cross displacement amplification in a lateral flow biosensor. … (more)
- Is Part Of:
- FEMS microbiology letters. Volume 368:Issue 3(2021)
- Journal:
- FEMS microbiology letters
- Issue:
- Volume 368:Issue 3(2021)
- Issue Display:
- Volume 368, Issue 3 (2021)
- Year:
- 2021
- Volume:
- 368
- Issue:
- 3
- Issue Sort Value:
- 2021-0368-0003-0000
- Page Start:
- Page End:
- Publication Date:
- 2021-01-19
- Subjects:
- Streptococcus pneumoniae -- multiple cross displacement amplification -- Antarctic thermal sensitive uracil-DNA glycosylase (AUDG) -- carryover contamination -- lateral flow biosensor
Microbiology -- Periodicals
579 - Journal URLs:
- http://onlinelibrary.wiley.com/journal/10.1111/(ISSN)1574-6968/issues ↗
http://www.sciencedirect.com/science/journal/03781097 ↗
http://onlinelibrary.wiley.com/ ↗
http://femsle.oxfordjournals.org/content/ ↗
http://firstsearch.oclc.org ↗ - DOI:
- 10.1093/femsle/fnab006 ↗
- Languages:
- English
- ISSNs:
- 0378-1097
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3905.300000
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15706.xml