Leadless pacemaker implantation quality: importance of the operator's experience. Issue 6 (3rd May 2020)
- Record Type:
- Journal Article
- Title:
- Leadless pacemaker implantation quality: importance of the operator's experience. Issue 6 (3rd May 2020)
- Main Title:
- Leadless pacemaker implantation quality: importance of the operator's experience
- Authors:
- Haeberlin, Andreas
Kozhuharov, Nikola
Knecht, Sven
Tanner, Hildegard
Schaer, Beat
Noti, Fabian
Osswald, Stefan
Servatius, Helge
Baldinger, Samuel
Seiler, Jens
Lam, Anna
Mosher, Luke
Sticherling, Christian
Roten, Laurent
Kühne, Michael
Reichlin, Tobias - Abstract:
- Abstract: Aims: Leadless cardiac pacemaker (PM) implantation differs from conventional PM implantation. While the procedure has been considered safe, recent real-world data raised concerns about the learning curve of new operators and their implantation quality. The goal of this study was to investigate the influence of the first operator's experience on leadless PM implantation quality and procedural efficiency. Methods and results: We performed a bicentric analysis of all Micra TPS™ implantations in two large tertiary referral hospitals. We assessed both leadless PM implantation quality based on the absence of complications (requiring intervention or prolonged hospitalization), good electrical performance (pacing threshold ≤ 1.5 V/0.24 ms, R-wave amplitude > 5 mV), and acceptable fluoroscopy duration (<10 min) as well as procedural efficiency in relation to the operator's experience. Univariate and multivariate logistic regression analyses were performed to identify predictors for implantation quality and procedural efficiency. Leadless PM implantation was successful in 106/111 cases (95.5%). Three patients (2.7%) experienced acute complications (one cardiac tamponade, one femoral bleeding, one posture-related PM exit block). Multivariate analysis showed that implantation quality of more experienced first operators was higher [odds ratio 1.09 (95% confidence interval 1.00–1.19), P = 0.05]. Procedural efficiency increased with operator experience as evidenced by an inverseAbstract: Aims: Leadless cardiac pacemaker (PM) implantation differs from conventional PM implantation. While the procedure has been considered safe, recent real-world data raised concerns about the learning curve of new operators and their implantation quality. The goal of this study was to investigate the influence of the first operator's experience on leadless PM implantation quality and procedural efficiency. Methods and results: We performed a bicentric analysis of all Micra TPS™ implantations in two large tertiary referral hospitals. We assessed both leadless PM implantation quality based on the absence of complications (requiring intervention or prolonged hospitalization), good electrical performance (pacing threshold ≤ 1.5 V/0.24 ms, R-wave amplitude > 5 mV), and acceptable fluoroscopy duration (<10 min) as well as procedural efficiency in relation to the operator's experience. Univariate and multivariate logistic regression analyses were performed to identify predictors for implantation quality and procedural efficiency. Leadless PM implantation was successful in 106/111 cases (95.5%). Three patients (2.7%) experienced acute complications (one cardiac tamponade, one femoral bleeding, one posture-related PM exit block). Multivariate analysis showed that implantation quality of more experienced first operators was higher [odds ratio 1.09 (95% confidence interval 1.00–1.19), P = 0.05]. Procedural efficiency increased with operator experience as evidenced by an inverse correlation of procedure time, time to the first deployment, fluoroscopy time, and the number of procedures performed (all P < 0.05). Conclusion: The operator's learning curve is a critical factor for leadless PM implantation quality and procedural efficiency. … (more)
- Is Part Of:
- Europace. Volume 22:Issue 6(2020)
- Journal:
- Europace
- Issue:
- Volume 22:Issue 6(2020)
- Issue Display:
- Volume 22, Issue 6 (2020)
- Year:
- 2020
- Volume:
- 22
- Issue:
- 6
- Issue Sort Value:
- 2020-0022-0006-0000
- Page Start:
- 939
- Page End:
- 946
- Publication Date:
- 2020-05-03
- Subjects:
- Leadless pacemaker -- Micra -- Experience -- Learning curve -- Implantation quality -- Safety
Arrhythmia -- Treatment -- Periodicals
Cardiac pacing -- Periodicals
Catheter ablation -- Periodicals
Heart -- Physiology -- Periodicals
Electrophysiology -- Periodicals
617.4120645 - Journal URLs:
- http://europace.oxfordjournals.org/ ↗
http://ukcatalogue.oup.com/ ↗ - DOI:
- 10.1093/europace/euaa097 ↗
- Languages:
- English
- ISSNs:
- 1099-5129
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - 3829.340450
British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15709.xml