Experimental study on the synergistic effect of gas extinguishing agents and water mist on suppressing lithium-ion battery fires. (December 2020)
- Record Type:
- Journal Article
- Title:
- Experimental study on the synergistic effect of gas extinguishing agents and water mist on suppressing lithium-ion battery fires. (December 2020)
- Main Title:
- Experimental study on the synergistic effect of gas extinguishing agents and water mist on suppressing lithium-ion battery fires
- Authors:
- Zhang, Lin
Li, Yongqi
Duan, Qiangling
Chen, Man
Xu, Jiajia
Zhao, Chunpeng
Sun, Jinhua
Wang, Qingsong - Abstract:
- Highlights: An improved fire extinguishing method was proposed. Synergistic effect of gas agents and water mist on LIB fire was studied. Gas agents reduce thermal buoyancy, to facilitate the water mist cool effectively. Abstract: Currently, effective suppression methods are still required to deal with lithium-ion battery (LIB) fires. In this paper, a novel synergistic fire extinguishing method of gas extinguishing agent (C6 F12 O, CO2 and HFC-227ea) and water mist is designed to evaluate the effect of their combination. A 243 Ah large-scale LIB with LiFePO4 as cathode is used in this work. Several cell parameters are measured to evaluate the suppression effect of fire extinguishing method, such as extinguishing time, maximum temperature, mass loss and heat release rate. Meanwhile, the cooling effect, fire extinguishing effect and economic benefit of different fire extinguishing methods are all considered. Results show that the suppression effect of synergistic fire extinguishing method is better than that of the single agent. Single application of water mist can hardly extinguish the flame, while the combination of gas extinguishing agents and water mist can extinguish the flame finally. However, the C6 F12 O extinguishes the flame immediately, while CO2 has a longer extinguishing time, and HFC-227ea cannot extinguish the flame. So in these experiments, the C6 F12 O combined with water mist exhibits the best extinguishing and cooling effect. The CO2 combined with water mistHighlights: An improved fire extinguishing method was proposed. Synergistic effect of gas agents and water mist on LIB fire was studied. Gas agents reduce thermal buoyancy, to facilitate the water mist cool effectively. Abstract: Currently, effective suppression methods are still required to deal with lithium-ion battery (LIB) fires. In this paper, a novel synergistic fire extinguishing method of gas extinguishing agent (C6 F12 O, CO2 and HFC-227ea) and water mist is designed to evaluate the effect of their combination. A 243 Ah large-scale LIB with LiFePO4 as cathode is used in this work. Several cell parameters are measured to evaluate the suppression effect of fire extinguishing method, such as extinguishing time, maximum temperature, mass loss and heat release rate. Meanwhile, the cooling effect, fire extinguishing effect and economic benefit of different fire extinguishing methods are all considered. Results show that the suppression effect of synergistic fire extinguishing method is better than that of the single agent. Single application of water mist can hardly extinguish the flame, while the combination of gas extinguishing agents and water mist can extinguish the flame finally. However, the C6 F12 O extinguishes the flame immediately, while CO2 has a longer extinguishing time, and HFC-227ea cannot extinguish the flame. So in these experiments, the C6 F12 O combined with water mist exhibits the best extinguishing and cooling effect. The CO2 combined with water mist has good economic benefit, better fire extinguishing effect and cooling effect in these experiments, which can also be considered in suppressing LiFePO4 LIB fires. … (more)
- Is Part Of:
- Journal of energy storage. Volume 32(2020)
- Journal:
- Journal of energy storage
- Issue:
- Volume 32(2020)
- Issue Display:
- Volume 32, Issue 2020 (2020)
- Year:
- 2020
- Volume:
- 32
- Issue:
- 2020
- Issue Sort Value:
- 2020-0032-2020-0000
- Page Start:
- Page End:
- Publication Date:
- 2020-12
- Subjects:
- Lithium-ion battery safety -- Gas fire extinguishing agent -- Water mist -- Suppression efficiency -- Synergistic effect
Energy storage -- Periodicals
Energy storage -- Research -- Periodicals
621.3126 - Journal URLs:
- http://www.sciencedirect.com/science/journal/2352152X ↗
http://www.sciencedirect.com/ ↗ - DOI:
- 10.1016/j.est.2020.101801 ↗
- Languages:
- English
- ISSNs:
- 2352-152X
- Deposit Type:
- Legaldeposit
- View Content:
- Available online (eLD content is only available in our Reading Rooms) ↗
- Physical Locations:
- British Library DSC - BLDSS-3PM
British Library HMNTS - ELD Digital store - Ingest File:
- 15705.xml